SH4B-05 IDEC Corporation, SH4B-05 Datasheet - Page 4

no-image

SH4B-05

Manufacturer Part Number
SH4B-05
Description
Socket, Relay; 14; 4; DIN Rail; 10 A; 100 Megohms Insulation, Resistance; M3.5
Manufacturer
IDEC Corporation
Type
Blader
Datasheet

Specifications of SH4B-05

Current Rating
10 A
Current, Rating
10 A
Dielectric Strength
2000 VAC, 1 Minute
Insulation, Resistance
100 Megohms (Min.)
Mounting
DIN Rail
Mounting Type
DIN Rail
Number Of Contacts
14
Number Of Pins
14
Number Of Poles
4
Screw Size
M3.5
Standards
UL Recognized, CSA Certified, CE Marked
Mating Relay Series
RH4B
Hold Down Spring
SH4B-02F1
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
For Use With RH Series Relay
Relays & Sockets
Specifi cations
Contact Material
Contact Resistance
Minimum Applicable Load
Operate Time
Release Time
Power Consumption
(approx.)
Insulation Resistance
Dielectric Strength
Operating Frequency
Vibration Resistance
Shock Resistance
Mechanical Life
Electrical Life
Operating
Temperature
Operating Humidity
Weight (approx.)
Note: Above values are initial values.
1. Measured using 5V DC, 1A voltage drop method
2. Measured at the rated voltage (at 20°C), excluding contact bouncing
3. Relays with indicator or diode: 1000V AC, 1 minute
4. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating
Release time of relays with diode: 40 ms maximum
temperature range of relays with indicator or diode is –25 to +40°C.
4
2
2
1
3
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
DPDT
SPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
Silver cadmium oxide
50mΩ maximum
24V DC, 30 mA; 5V DC, 100 mA (reference value)
20ms maximum
25ms maximum
20ms maximum
25ms maximum
AC: 1.1VA (50Hz), 1VA (60Hz)
AC: 1.4VA (50Hz), 1.2VA (60Hz)
AC: 2VA (50Hz), 1.7VA (60Hz)
AC: 2.5VA (50Hz), 2VA (60Hz)
100MΩ minimum (500V DC megger)
Between live and dead parts:
Between contact and coil:
Between contacts of the same pole: 1,000V AC, 1 minute
Between live and dead parts:
Between contact and coil:
Between contacts of different poles: 2,000V AC, 1 minute
Between contacts of the same pole: 1,000V AC, 1 minute
Electrical:
Mechanical:
Damage limits:
Operating extremes:
Damage limits:
Operating extremes:
50,000,000 operations minimum
500,000 operations minimum (120V AC, 10A)
200,000 operations minimum (120V AC, 10A)
–25 to +50°C (no freezing)
–25 to +40°C (no freezing)
45 to 85% RH (no condensation)
SPDT: 24g, DPDT: 37g, 3PDT: 50g, 4PDT: 74g
USA: 800-262-IDEC
1,800 operations/hour maximum
18,000 operations/hour maximum
10 to 55Hz, amplitude 0.5 mm
10 to 55Hz, amplitude 0.5 mm
1,000m/s
200m/s
100m/s
2
2
(20G - SPDT, DPDT)
(10G - 3PDT, 4PDT)
2
(100G)
DC: 0.8W
DC: 0.9W
DC: 1.5W
DC: 1.5W
2,000V AC, 1 minute
2,000V AC, 1 minute
2,000V AC, 1 minute
2,000V AC, 1 minute
Canada: 888-317-IDEC
RH Series
729