CTAR-12 Chemtronics, CTAR-12 Datasheet

no-image

CTAR-12

Manufacturer Part Number
CTAR-12
Description
Chemical, Conformal Coating, Konform Acrylic Resin, 11.5 Oz Aerosol Can
Manufacturer
Chemtronics
Type
Conformalr
Datasheet

Specifications of CTAR-12

Chemical Component
Acrylic Copolymer Resin/Ethanol/Methyl Ethyl Ketone/n-Butyl Acetate/n-Propyl Acetate/Propylene Glycol Monomethyl Ether Acetate/Propane/Isobutane Blend
Dielectric Strength
8300 V⁄mil
Dispensing Method
Aerosol
Primary Type
Coating
Special Features
Prevent Arcing and Shorting
Standards
UL Recognized
Temperature Range
-59 to +132 °C
Temperature, Rating
-59 to +132 °C
Time, Setting
30 min.
Weight
11.5 Oz.
Lead Free Status / Rohs Status
RoHS Compliant part Hazardous Materials
ITW CHEMTRONICS
SECTION 1: CHEMICAL PRODUCT AND COMPANY INFORMATION
Company Address:
8125 Cobb Center Drive
Kennesaw, GA 30152
Product Code: CTAR-12, CTAR-12C
SECTION 2: COMPOSITION/INFORMATION ON INGREDIENTS
Product Ingredient Information
n-Butyl acetate
n-propyl acetate
Propylene glycol monomethyl ether acetate
Ethanol
Propane/isobutane blend
Methyl ethyl ketone
Acrylic copolymer resin
SECTION 3: HAZARD IDENTIFICATION
Emergency Overview: Clear, colorless liquid with strong, fruity, ethereal odor. This product is extremely flammable. Liquid will irritate eyes and skin under repeated
or prolonged exposure. Breathing high concentrations of product may produce drowsiness and a headache.
Potential Health Effects:
Eyes: Liquid, aerosols and vapors of this product are irritating and can cause pain, tearing, reddening and swelling accompanied by a stinging sensation.
Skin: Contact causes skin irritation.
Ingestion: Harmful if swallowed. Irritating to the mouth, throat and stomach. May cause vomiting.
Inhalation: Harmful if inhaled. High concentrations in immediate area can displace oxygen and cause dizziness, unconsciousness and even death with longer exposure.
Keep people away from such vapors without self-contained breathing apparatus.
Pre-Existing Medical Conditions Aggravated by Exposure: Heart, lung, skin, eye.
SECTION 4: FIRST AID MEASURES
Eyes:
and tested by medical personnel if irritation develops or persists.
Skin: Wash skin with soap and water. Remove contaminated clothing. Get medical attention if irritation develops or persists. Wash clothing separately before reuse.
Ingestion: If swallowed, do not induce vomiting. Keep head below knees to minimize chance of aspirating material into the lungs. Never give anything by mouth to an
unconscious person. Get medical attention immediately.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
SECTION 5: FIRE FIGHTING MEASURES
Flash Point: 30 F (-1C) (liquid TCC), -156 F (-104C) (propellant)
Extinguishing Media: Use alcohol foam, carbon dioxide or water spray when fighting fires involving this material.
Fire Fighting Instructions: As in any fire, wear self-contained breathing apparatus (pressure demand, MSHA/NIOSH approved or equivalent) and full protective gear.
SECTION 6: ACCIDENTAL RELEASE MEASURES
Large Spills: Shut off leak if possible and safe to do so. Wear self-contained breathing apparatus and appropriate personal protective equipment. Absorb spill with inert
material (i.e. dry sand or earth), then place in a chemical waste container for proper disposal. Do not flush to sewer. Avoid runoff into storm sewers and ditches that
lead to waterways.
Small Spills: Absorb spill with inert material (i.e. dry sand or earth), then place in a chemical waste container for proper disposal.
SECTION 7: HANDLING AND STORAGE
Avoid prolonged or repeated contact with skin, eyes or clothing. Wash hands before eating. Use with adequate ventilation. Avoid breathing product vapor. Do not
reuse this container. Store in a cool dry place, away from heat, sparks or flames. Keep container tightly closed when not in use. Do not store in direct sunlight.
KEEP OUT OF REACH OF CHILDREN.
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION
Exposure Guidelines:
CHEMICAL NAME
Propylene glycol monomethyl ether acetate
n-Propyl acetate
n-Butyl acetate
Ethanol
Methyl ethyl ketone
Propane
Work/Hygienic Practices: Good general ventilation should be sufficient to control airborne levels. Local exhaust ventilation may be necessary to control any air
contaminants to within their TLVs during the use of this product. If vapor concentration exceeds TLV, use NIOSH approved organic vapor cartridge respirator.
safety glasses with side shields (or goggles) and rubber or other chemically resistant gloves when handling this material.
NFPA and HMIS Codes:
Health
Flammability
Reactivity
Personal Protection
Product Identification
Immediately flush with plenty of water. After initial flushing, remove any contact lenses and continue flushing for at least 15 minutes. Have eyes examined
Product Information: 800-TECH-401
Customer Service:
®
800-645-5244
NA
ACGIH TLV
200 ppm
150 ppm
1000 ppm
200 ppm
NA
(Formerly Konform ® AR 2000)
KONFORM ® AR
68476-86-8
26760-85-0
LEL/UEL: Not determined (% by volume in air)
NFPA
CAS No.
-
123-86-4
109-60-4
108-65-6
Page 1 of 2
1
3
1
64-17-5
78-93-3
OSHA PEL
NA
200 ppm
150 ppm
1000 ppm
200 ppm
1000 ppm
Emergency:
Revision Date:
(Chemtrec) 800-424-9300
February 10, 2007
ACGIH STEL
NA
250 ppm
200 ppm
NA
300 ppm
NA
HMIS
B
1
3
1
Wt. % Range
10.0-20.0
10.0-20.0
10.0-20.0
10.0-20.0
20.0-30.0
5.0-15.0
2.0-5.0
MSDS # 0708
Wear

CTAR-12 Summary of contents

Page 1

... SECTION 1: CHEMICAL PRODUCT AND COMPANY INFORMATION Company Address: 8125 Cobb Center Drive Kennesaw, GA 30152 Product Information: 800-TECH-401 Customer Service: 800-645-5244 Product Identification Product Code: CTAR-12, CTAR-12C SECTION 2: COMPOSITION/INFORMATION ON INGREDIENTS Product Ingredient Information n-Butyl acetate n-propyl acetate Propylene glycol monomethyl ether acetate Ethanol Propane/isobutane blend ...

Page 2

... ITW CHEMTRONICS SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES Physical State: Clear, colorless liquid Odor: Strong, fruity, ethereal solvent pH: NA Vapor Pressure: 12 mmHg @ 68 F Boiling point: liquid: >210F (>99C); propellant: -43.7 F (-42C) Vapor Density: >1 (Air=1) SECTION 10: STABILITY AND REACTIVITY Stability: This product is stable. Conditions to Avoid: Do not spray near open flames, red hot surfaces or other sources of ignition. ...