bility of certain well-defined failure(s) can be reduced to a point where the resulting fault(s) can be, for the most part,
disregarded – that is, "excluded."
Fault exclusion is a tool a designer can use during the development of the safety-related part of the control system
and the risk assessment process. Fault exclusion allows the designer to design out the possibility of various failures
and justify it, through the risk assessment process, to meet the intent requirements of Category 2, 3 or 4. See ISO
13849-1/-2 for further information.
Monitoring of Safety Devices
Requirements vary widely for the level of control reliability or safety category per ISO 13849-1 (EN954-1) in safety
applications. While Banner Engineering always recommends the highest level of safety in any application, it is the
responsibility of the user to safely install, operate and maintain each safety system and comply with all relevant laws
and regulations.
While only two applications are listed below, the Module can monitor a variety of devices as long as the input require-
ments are complied with (see Electrical Installation and Specifications). The Safety Module does not have 500
ms simultaneity between inputs and thus can not be used for monitoring a two-hand control. In all cases,
the safety performance (integrity) must reduce the risk from identified hazards as determined by the machine's risk
assessment.
Emergency-Stop Push Buttons and Rope/Cable Pull Switches:
The safety inputs can be interfaced with positive-opening switches to monitor an emergency-stop (E-stop) push
button or rope/cable pull. The switch must provide one or two contacts for safety which are closed when the switch
is armed. Once activated, the E-stop switch must open all its safety-rated contacts, and must require a deliberate
action (such as twisting, pulling, or unlocking) to return to the closed-contact, armed position. The switch must be
a "positive-opening" (or direct-opening) type, as described by IEC 60947-5-1.
Standards ANSI NFPA 79, IEC/EN 60204-1, and ISO 13850 specify additional emergency stop switch device re-
quirements, including the following:
4
The level of safety circuit integrity can be greatly impacted by the design and installation of the safety devices and
the means of interfacing of those devices. A risk assessment must be performed to determine the appropriate
safety circuit integrity level or safety category as described by ISO 13849-1 (EN 954-1) to ensure that the
expected risk reduction is achieved and that all relevant regulations and standards are complied with.
Do not mute or bypass any emergency stop device. ANSI NFPA79 and IEC/EN 60204-1 require that the
emergency stop function remain active at all times. Muting or bypassing the Safety Outputs will render the
emergency stop function ineffective.
Emergency-stop push buttons shall be located at each operator control station and at other operating stations
where emergency shutdown is required.
Stop and emergency-stop push buttons shall be continuously operable and readily accessible from all control and
operating stations where located. Do not mute or bypass E-stop buttons or rope/cable pulls.
Actuators of emergency-stop devices shall be colored red.The background immediately around the device actuator
shall be colored yellow (where possible). The actuator of a push-button-operated device shall be of the palm or
mushroom-head type.
The emergency-stop actuator shall be a self-latching type.
WARNING . . . Emergency Stop Functions
WARNING . . . Safety Categories
Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules