ES-FA-9AA BANNER ENGINEERING, ES-FA-9AA Datasheet - Page 7

no-image

ES-FA-9AA

Manufacturer Part Number
ES-FA-9AA
Description
Module; Relay; Red LED; 24; UL Listed
Manufacturer
BANNER ENGINEERING
Datasheets

Specifications of ES-FA-9AA

Light Source
Red LED
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Configuration
3PST-NO
No. Of Poles
3
Lead Free Status / Rohs Status
RoHS Exempt Product
Figure 4. Series connection of multiple
Figure . Hookup using contacts from two
S11
from the E-Stop Safety Module and
all power from the machine being
controlled before making any wire
connections.
Electrical installation and wiring must
be made by qualified personnel and
must comply with the NEC (National
Electrical Code), EN60204-1 and -2,
and all applicable local standards and
codes.
Banner Engineering Corp.
S11 S1
www.bannerengineering.com • Tel: 763.544.3164
S1
E-stop switches
safety switches
Safety Interlock
Safety Interlock
Switch #1
Switch #
CAUTION. . .
Shock Hazard
Always disconnect power
S
S1
Minneapolis, MN U.S.A.
S
Safety gate
or guard
S1
The E-Stop Safety Module must be installed inside an enclosure. It is not designed for
exposed wiring. It is the user’s responsibility to house the Safety Module in an enclosure
with NEMA 3 (IEC IP54) rating, or better.
Dimensions of the Safety Module are shown in the diagram on page 10. The Safety Module
mounts directly to standard 35 mm DIN rail.
Heat Dissipation Considerations
For reliable operation, the user must ensure that the operating specifications are not
exceeded. The enclosure must provide adequate heat dissipation, so that the air closely
surrounding the Module does not exceed the maximum operating temperature stated in
the Specifications (page 11). Methods to reduce heat build-up include venting, forced
airflow (e.g., exhaust fans), adequate enclosure exterior surface area, and spacing between
modules and other sources of heat.
It is not possible to give exact wiring instructions for a device such as an E-Stop Safety
Module which interfaces to a multitude of machine control configurations. The following
guidelines are general in nature.
The ES-FA-9AA Module has no delay function. Its output relay contacts open within 25
milliseconds after an E-stop switch contact opens. This classifies these E-Stop Safety
Modules as functional “Category 0” E-stop controls, as defined by NFPA 79 (National
Fire Protection Association Standard for Industrial Machinery) and IEC/EN60204-1
(European Standard: “Safety of Machinery, Emergency Stop Equipment, Functional Aspects
– Principles of Design”).
Connect the poles of the E-stop switches as shown in Figures 2 and 3. The switches
are shown in the “armed” position with both contacts closed. Multiple E-stop switches
connected to one E-Stop Safety Module must be series connected (see Figure 4 and the
warning on page 8).
The ES-FA-9AA may be used as a safety gate monitoring module. To achieve Category
4 operation per ISO 13849-1 (EN954-1), two positive-opening safety switches operate
concurrently when the gate or guard is opened (see Figure 5).
The Safety Modules verify concurrent opening of two contacts – one from each safety
switch. Reset of the Safety Modules is not possible if one switch fails to open, or if a short
circuit between the safety switches occurs.
Please contact the Banner Factory Applications Group at the numbers listed on the last page
to discuss your intended use.
E-Stop Safety Module –
Connection of Safety Switches
Connection of E-Stop Switch
Mechanical Installation
Electrical Installation
ES-FA-9AA
P/N 60606 rev. B
7