H3CA-8-AC100/110/120 Omron Automation, H3CA-8-AC100/110/120 Datasheet - Page 2

no-image

H3CA-8-AC100/110/120

Manufacturer Part Number
H3CA-8-AC100/110/120
Description
Relay; SSR; Timing; On Delay; DPDT; Cur-Rtg 3A; Ctrl-V 100/110/120AC; Vol-Rtg 250AC
Manufacturer
Omron Automation
Datasheet

Specifications of H3CA-8-AC100/110/120

Contact Form
DPDT
Current, Rating
3 A
Dielectric Strength
2000 VAC @ 50⁄60 Hz, 1000 VAC @ 50⁄60 Hz
Function
Timing
Material, Body
Plastic Case
Mounting Type
Socket
Number Of Pins
8
Relay Type
Solid State
Standards
UL, CSA, CE
Temperature, Operating, Maximum
55 °C
Temperature, Operating, Minimum
-10 °C
Termination
Plug-In
Timer Type
On Delay
Timing Range
0.1 sec. to 9990 hrs.
Voltage, Control
100⁄110⁄120 VAC
Voltage, Rating
250 VAC
Supply Voltage
100/110/120 VAC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H3CA-8-AC100/110/120
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
■ Ratings
Note: 1. Single-phase, full-wave rectified power sources may be used for 24 to 240 VDC.
■ Characteristics
Accuracy of operating
time
Influence of voltage
Influence of
temperature
Setting error
Reset time
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
EMC
Weight
Rated supply voltage
(See note 2.)
Operating voltage range
Power consumption
Control outputs
2. Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor.
Item
±0.3% ±0.05 s
±0.5% ±0.05 s max.
H3CA-A/-FA: 0.5 s max.
H3CA-8H/-8: 0.1 s max.
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts and between contact and
control circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
3 kV
Destruction: 10 to 55 Hz with 0.75-mm double amplitude for 1 h each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude for 10 min each in three directions
Destruction: 980 m/s
Malfunction: 98 m/s
Operating: –10°C to 55°C
Operating: 35% to 85%
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
UL508, CSA C22.2 No. 14, LR, NK
Conforms to EN61010-1.
(EMI)
Emission Enclosure:
Emission AC mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted
Disturbance:
Immunity Burst:
Immunity Surge:
Immunity Voltage Dip/Interruption
H3CA-A:
H3CA-FA: approx. 190 g
24 to 240 VAC (50/60 Hz),
12 to 240 VDC (permissible ripple:
20% max.)
90% to 110% of rated supply voltage 85% to 110% of rated supply voltage
AC: approx. 4 VA
DC: approx. 2 W
3 A at 250 VAC, resistive load (cosφ = 1)
approx. 110 g
100,000 operations min. (3 A at 250 VAC, cosφ = 1 at 1,800 operations/h)
See Lift-test Curve for more details.
H3CA-A/H3CA-FA
2
2
EN61326
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61326
EN61000-4-2:
EN61000-4-3:
EN61000-4-6:
EN61000-4-4:
EN61000-4-5:
EN61000-4-11:
100/110/120, 200/220/240 VAC, (50/60 Hz),
24 VDC, 110 VDC (permissible ripple: 20% max.) (See note 1.)
AC: approx. 10 VA/1 W
DC: approx. 1 W
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
10 V (0.15 to 80 MHz) (according to EN61000-6-2)
2 kV power-line (level 3);
1 kV I/O signal-line (level 4)
1 kV line to lines (power and output lines) (level 3);
2 kV line to ground (power and output lines) (level 3)
0.5 cycle, 100% (rated voltage)
H3CA-8
AC: approx. 10 VA/1.5 W
DC: approx. 2 W
H3CA-8H
H3CA
2

Related parts for H3CA-8-AC100/110/120