G3PA-210B-VD-DC5-24 Omron Automation, G3PA-210B-VD-DC5-24 Datasheet - Page 3

no-image

G3PA-210B-VD-DC5-24

Manufacturer Part Number
G3PA-210B-VD-DC5-24
Description
Relay; SSR; Zero-Switching; Cur-Rtg 10A; Ctrl-V 5-24DC; Vol-Rtg 24-240AC; Pnl-Mnt
Manufacturer
Omron Automation
Datasheet

Specifications of G3PA-210B-VD-DC5-24

Application
Long service life for circuits that cycle frequently
Current, Leakage, Off-state
5 mA (Max.) @ 120 VAC
Current, Rating
10 A
Dielectric Strength
4000 VAC
Function
Zero-Switching
Impedance, Input
7 mA
Mounting Type
Panel
Relay Type
Solid State
Standards
UL, CSA and VDE
Temperature, Ambient, Maximum
+80 °C
Temperature, Ambient, Minimum
-30 °C
Termination
Screw
Voltage, Control
24 VDC
Voltage, Rating
240 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Specifications
■ Ratings (at an Ambient Temperature of 25 C)
Input
Output
Refer to Engineering Data for further details.
G3PA-210B-VD
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-210BL-VD
G3PA-220BL-VD
G3PA-240BL-VD
G3PA-260BL-VD
G3PA-210B-VD
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-420B-VD
G3PA-430B-VD
G3PA-420B-VD-2
G3PA-430B-VD-2
G3PA-450B-VD-2
G3PA-210B(L)-VD
G3PA-220B(L)-VD
G3PA-240B(L)-VD
G3PA-260B(L)-VD
G3PA-420B-VD
G3PA-430B-VD
G3PA-420B-VD-2
G3PA-430B-VD-2
G3PA-450B-VD-2
Model
Model
5 to 24 VDC
5 to 24 VDC
24 VAC
12 to 24 VDC
24 to 240 VAC (50/60 Hz)
200 to 400 VAC (50/60 Hz)
200 to 480 VAC (50/60 Hz)
Rated voltage
Rated load voltage
4 to 30 VDC
4 to 30 VDC
19.2 to 26.4 VAC
9.6 to 30 VDC
Operating Voltage
range
19 to 264 VAC (50/60 Hz)
180 to 440 VAC (50/60 Hz)
180 to 528 VAC (50/60 Hz)
Load voltage range
7 mA max.
20 mA max.
1.4 k
7 mA max.
Input current
impedance
Applicable load
20%
0.1 to 10 A at 40°C
0.1 to 20 A at 40°C
0.5 to 40 A at 40°C
0.5 to 60 A at 40°C
0.5 to 20 A at 30°C
0.5 to 30 A at 30°C
0.5 to 20 A at 30°C
0.5 to 30 A at 30°C
0.5 to 50 A at 30°C
4 VDC max.
4 VDC max.
19.2 VAC max.
9.2 VDC max.
Load current
Must operate voltage
Voltage level
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
1 VDC min.
1 VDC min.
4.8 VAC min.
1 VDC min.
Must release voltage
Inrush current
G3PA

Related parts for G3PA-210B-VD-DC5-24