E2K-C25MY1 Omron Automation, E2K-C25MY1 Datasheet
E2K-C25MY1
Specifications of E2K-C25MY1
Available stocks
Related parts for E2K-C25MY1
E2K-C25MY1 Summary of contents
Page 1
... Unshielded 34 dia. Noise-resistant Models Accessories (Order Separately) Mounting Brackets Appearance Model Quantity Y92E-A34 1 Sensing distance Output configuration DC 3-wire, NPN 2-wire DC 3-wire, NPN AC/DC 2-wire Remarks Provided with the product. Model Operation mode NO NC E2K-C25ME1 E2K-C25ME2 E2K-C25MY1 E2K-C25MY2 E2K-C20MC1 E2K-C20MC2 E2K-C20MT1 E2K-C20MT2 1 ...
Page 2
... Sensing rials surface Accessories Mounting Bracket, Instruction manual * The set distances are sensing distances applicable to standard sensing objects. Refer to Engineering Data on page 4 for other materials. E2K-C25ME2 E2K-C25MY1 100 to 220 VAC (90 to 250 VAC), 50/ 200 mA (resistive load) Refer to Engineering Data on page 4. Operation indicator (red) Surge suppressor 2% max ...
Page 3
... VDC, 1.7 mA max. at 110 VAC (50/60 Hz), --- 2.5 mA max. at 250 VAC (50/60 Hz) Refer to Engineering Data on page 200 mA (resistive load) AC power max., DC power max. Refer to Engineering Data on page 4. 1,500 VAC, 50/60 Hz for 1 min between current-carrying parts and case 2 or greater to extend the cable. E2K-C E2K-C20MT2 --- --- 3 ...
Page 4
... Load NO E2K-C20MC1 (between brown and black leads) Operation Indicator (yellow) Sensing object Load NC E2K-C20MC2 (between brown and black leads) Operation Indicator (yellow) Sensing Object Size vs. Sensing Distance E2K-C25M Grounded metal plate Square sensing 20 object Ungrounded X metal plate ( Phenolic resin plate ( ...
Page 5
... AC 2-Wire Models Operation Model mode NO E2K-C25MY1 NC E2K-C25MY2 AC/DC 2-Wire Models Operation Model mode NO E2K-C20MT1 NC E2K-C20MT2 Timing chart Sensing Present object Not present Operate Load Reset Operation ON indicator (red) OFF Present Sensing object Not present Operate Load Reset Operation ON indicator (red) OFF ...
Page 6
... Two, 5.5-dia. mounting holes The holes are not drilled completely through. Drill through the holes before using them. 45 57.6 E2K-C (Unit: mm) Screw hole for sensitivity adjustment - + Indicator Insulator diameter Models: Detection indicator (red Insulator diameter: Y Models: Operation indicator (red) Sensitivity adjuster E2K ...