Description
Converter; 12 V; 23.4 A; 12 V; 4.77 A (Typ.)
Manufacturer
Cosel U.S.A. Inc.
Type
Commercial, Industrialr
Datasheet

Specifications of CBS1002412

Brand/series
CB Series
Configuration
Enclosed
Current, Input
4.77 A (Typ.)
Current, Output
23.4 A
Mounting Type
Panel
Number Of Outputs
1
Operation
Linear
Output
12 VDC @ 8.4 A
Power, Output
100.8 W
Primary Type
DC-DC Converter
Special Features
Remote On/Off, Remote Sense
Standards
cULus Recognized, TUV Approved, CE Marked
Voltage, Input
18 to 36 VDC
Voltage, Input Range
12 V
Voltage, Output
12 VDC
High Quality
Documented Field Failure Rate Less than 0.012%
Dc Input
36~76 VDC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CBS1002412
Manufacturer:
COSEL
Quantity:
452
Part Number:
CBS1002412
Quantity:
50
¡
ISOLATION
ENVIRONMENT
SAFETY
OTHERS
GENERAL SPECIFICATIONS
*1
*2
*3
*4
Base Plate(Aluminum)
INPUT CURRENT CHARACTERISTICS (CBS1002428)
At rated input(DC24V,DC48V) and rated load.
Ripple and ripple noise is measured by using measuring board with recommended capacitor Co & the film capacitor 0.1mF.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
When the input voltage is in the range of DC18 - 20V, DC36 - 40V output voltage adjustment range is 60 - 105% (except for 1R8/2R5).
External view
Performance data
Case(PBT)
10
8
6
4
2
0
0
7-
-VIN
CASE
Name Plate
+VIN
º 1
INPUT-OUTPUT
INPUT-CASE PIN , BASE PLATE DC1 , 500V or AC1 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( 20 t 15 C )
OUTPUT-CASE PIN , BASE PLATE AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( 20 t 15 C )
OPERATING TEMP. , HUMID.AND ALTITUDE -40 to +100 C ( On aluminum base plate ), 20 - 95%RH ( Non condensing ) ( Refer to DERATING CURVE ), 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -40 to +100 C , 20 - 95%RH ( Non condensing ), 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
(4.8)
RC
0.1
10
57.9
48.3
INPUT VOLTAGE
max
0.5
20
Lot No.
DC1 , 500V or AC1 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( 20 t 15 C )
10 - 55Hz , 49.0m/s
196.1m/s
UL60950-1 , C-UL , EN60950-1
57.9 X 12.7 X 61.0mm ( W X H X D ) / 83g max
Conduction cooling ( e.g. heat radiation from the aluminum base plate to the attached heat sink )
-S
TRM
+S
-VOUT
+VOUT
V
Io
2
Io
Mounting Hole
2-
=
30
4-
( 20G ), 11ms , once each along X , Y and Z axis
º 2
=
100
M
50
3
0.2
%
%
2
( 5G ), 3minutes period , 60minutes each along X , Y and Z axis
40
¡
INPUT CURRENT CHARACTERISTICS (CBS1004828)
10
8
6
4
2
0
0
¶Recomending size for processing PCB
CBS100
20
48.3
[1.9]
7-
INPUT VOLTAGE
º
(TOP VIEW)
1.5
¶Weight : 83g or less
¶Tolerance : 0.3
¶Case : PBT
¶Base Plate: Aluminum
¶Dimensions in mm.
¶Mounting hole screwing torque
Io
40
=
50
%
: 0.4N•m(5.0kgf•cm)max
V
Io
60
=
2-
4-
100
¶Dimensions :
¶Div. : 0.5inch
º
º
2.5
3.5
%
80
[inch]
H-23
mm
CBS

Related parts for CBS1002412