405A100F2X ATC Diversified Electronics, 405A100F2X Datasheet - Page 4

no-image

405A100F2X

Manufacturer Part Number
405A100F2X
Description
Relay; E-Mech; Timing; On Delay; SPDT; Cur-Rtg 10A; Ctrl-V 24-240/24AC/DC; Socket Mnt
Manufacturer
ATC Diversified Electronics
Datasheet

Specifications of 405A100F2X

Brand/series
405A Series
Contact Form
SPDT
Current, Rating
10 A
Function
Timing
Mounting Type
Socket
Number Of Pins
8
Power, Rating
240 VA
Relay Type
Electro Mechanical
Standards
cULus, CSA, CE
Termination
Plug-In
Timer Type
On Delay
Timing Range
1 or 10 sec.⁄min.⁄hrs.
Voltage, Control
240⁄24 VAC⁄VDC
Voltage, Rating
250⁄30 VAC⁄VDC
Timing Ranges
1 and 10 Sec, Min., Hours
Universal Power Supply
24-240 VAC and 24 VDC
MODELS
CONTACT
RATING
CONTACT
MATERIAL
TEMPERATURE
RATING
NOISE
IMMUNITY
MOUNTING
POWER
REQUIRE-
MENTS
REPEAT
ACCURACY
MINIMUM
SETTING
SETTING
ACCURACY
RESET
WEIGHT
\\\
SPECIFICATIONS
405A100F1X
405A500F1X
405A100F2X
405A500F2X
Both models available in 6 ranges
from 1 SEC to 10 HRS or 5 SEC to 50 HRS
Rated 10 AMPS resistive at 30 VDC or
250 VAC (or less)
1/8 HP @120 VAC
1/4 HP @ 240 VAC
240 VA @ 240 VAC
LIFE: 10 million operation with no load 100,000
operations with: 10 AMPS at 30 VDC (or less) or
10 AMPS at 250 VAC (or less)
Silver Cadmium Oxide
0 to 122°F (-18°C to 50°C)
Showering ARC per NEMA ICS 2-230. In addition,
the 405A will withstand a voltage surge of 4500
volts for 50 µSEC without damage.
Plug-in octal base; mounts in any position with
retaining clip.
Options: Surface mounting socket
Universal power supply - reverse polarity protected
Unit will accept power from 24 to 240 VAC, 50 or
60 Hz, (+10%, - 20%)
24 VDC (+20%, - 20%)
Varies as a function of temperature. Any voltage
(constant temperature): +/-0.5%*
Any voltage (32° F to 140° F): +/-1.5%*
Any voltage (0° F to 140° F): +/-2.0%*
*Variation from average actual time.
2% of range, with the exception of 50 mSEC on
the 1 second range
+/-5% of range
The TDR will reset properly and not start timing when
subjected to an open start switch leakage of 1.5 mA
or less. (Prox switch and Triac drive applications)
5 oz. (140g)
DC
AC
b
a
c
DIN rail mounting socket
Panel-mounting adapter kit
Plug-on socket kit
ON-Delay w/instantaneous & delayed
relays (1 or 10 SEC/MIN/HRS)
ON-Delay w/instantaneous & delayed
relays (5 or 50 SEC/MIN/HRS)
ON-Delay/Interval with (1) DPDT
relay (1 or 10 SEC/MIN/HRS)
ON-Delay/Interval with (1) DPDT
relay (5 or 50 SEC/MIN/HRS)
Inrush - 1.5 Amps
Power required - 1.2 watts
Maximum ripple @100Hz - 5%
Current required - 50mA
Power required - 1.2 watts
“F” option - Peak inrush current =
2 AMPS @ 24 VDC
“N” option - Peak inrush current =
150 mA @ 24 VDC
0 to 20 mSEC power interruption:
guaranteed no reset.
20 to 65 mSEC; it may reset (40
mSEC typical reset).
Over 65 mSEC guaranteed to reset.
Accessories
8-Pin surface/DIN rail socket
Hold down for above socket
Panel mounting bracket
Plug-in socket kit (8-pin)
8-Pin panel socket w/rear facing
terminals
\\\
(low inrush current for short-circuit protected sensors)
WIRING
WIRING
MODEL 405A...F1X
MODEL 405A...F2X
MODEL NUMBER
(with instantaneous contacts) Timing Mode
24 to 240 VAC (50/60 Hz) and 24 VDC F
(1 or 10 SEC/MIN/HRS)
(5 or 50 SEC/MIN/HRS)
Six dial-selected ranges
Six dial-selected ranges
> > > > > >
Voltage & Frequency
Interval Timing Modes
TERMINAL WIRING
Range
0000-825-85-00
0407-025-13-00
0405-320-02-00
0319-261-45-00
600-3-0011
405A
8-pin ON-Delay,
8-pin ON-Delay
Arrangement
12 VDC
24 VDC
100
500
Standard
Features
Special K
N
E
1
2
X
23

Related parts for 405A100F2X