Note 1: Each table below illustrates the confi guration of fi ve switches to the 11713B/C.
Note 2: Five additional switches can be driven by Attenuator Y (front panel pushbuttons 5, 6, 7, 8 & 0) using the same confi guration as Attenuator X.
Note 3: 2,000,000 switching cycles at 0.7 A for contact pairs 9 and 0. For more details, please refer to the “Supplemental characteristics” table on page 3.
Table D-4:
Table D-5:
Table D-6:
Front Panel Pushbutton
Front Panel Pushbutton
Front Panel Pushbutton
Attenuator X
Attenuator X
Attenuator X
1
2
3
4
9
1
2
3
4
9
1
2
3
4
9
Confi guration of 11713B/C (Option 201) to 8762A/B/C/F SPDT switches
Confi guration of 11713B/C (Option 201) to 8763A/B/C bypass switches
Confi guration of 11713B/C (Option 201) to 8764A/B/C bypass switches
From 11713B/C (Option 201)
From 11713B/C (Option 201)
From 11713B/C (Option 201)
LED
OFF
OFF
OFF
OFF
OFF
LED
OFF
OFF
OFF
OFF
OFF
LED
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Viking Connector
Viking Connector
Viking Connector
Pin Number
Pin Number
Pin Number
2 (GND)
2 (GND)
2 (GND)
1 (VCC)
1 (VCC)
1 (VCC)
11
11
11
5
7
9
4
5
7
9
4
5
7
9
4
Interface Cable
Interface Cable
Interface Cable
Bare Wire Color
Bare Wire Color
Bare Wire Color
White/Brown
White/Brown
White/Brown
Orange
Orange
Orange
Brown
Brown
Brown
Violet
Black
Violet
Black
Violet
Black
Gray
Gray
Gray
Red
Red
Red
Solder Terminal
Solder Terminal
Solder Terminal
Number
Number
Number
10
C
C
C
2
1
1
1
1
1
2
1
1
1
1
1
2
1
1
1
1
1
To 8762A/B/C/F (Option T15/T24)
To 8763A/B/C (Option T15/T24)
1 terminated, 2 to 3 closed, 4 open
1 terminated, 2 to 3 closed, 4 open
1 terminated, 2 to 3 closed, 4 open
1 terminated, 2 to 3 closed, 4 open
1 terminated, 2 to 3 closed, 4 open
To 8764A/B/C (Option T15/T24)
1 open, 2 to 3 closed, 4 to 5 closed
1 to 2 closed, 3 to 4 closed, 5 open
1 open, 2 to 3 closed, 4 to 5 closed
1 to 2 closed, 3 to 4 closed, 5 open
1 open, 2 to 3 closed, 4 to 5 closed
1 to 2 closed, 3 to 4 closed, 5 open
1 open, 2 to 3 closed, 4 to 5 closed
1 to 2 closed, 3 to 4 closed, 5 open
1 open, 2 to 3 closed, 4 to 5 closed
1 to 2 closed, 3 to 4 closed, 5 open
1 to C closed, 2 terminated
2 to C closed, 1 terminated
1 to C closed, 2 terminated
2 to C closed, 1 terminated
1 to C closed, 2 terminated
2 to C closed, 1 terminated
1 to C closed, 2 terminated
2 to C closed, 1 terminated
1 to C closed, 2 terminated
2 to C closed, 1 terminated
1 to 2 closed, 3 to 4 closed
1 to 2 closed, 3 to 4 closed
1 to 2 closed, 3 to 4 closed
1 to 2 closed, 3 to 4 closed
1 to 2 closed, 3 to 4 closed
RF Path
RF Path
RF Path
(Option T15/T24)
(Option T15/T24)
(Option T15/T24)
GND for all 5 DUTs
GND for all 5 DUTs
GND for all 5 DUTs
Device Under Test
VCC for all 5 DUTs
Device Under Test
VCC for all 5 DUTs
Device Under Test
VCC for all 5 DUTs
DUT 1
DUT 2
DUT 3
DUT 4
DUT 5
DUT 1
DUT 2
DUT 3
DUT 4
DUT 5
DUT 1
DUT 2
DUT 3
DUT 4
DUT 5
(DUT)
(DUT)
(DUT)