SR103AM02 Sti (Scientific Technologies, Inc.), SR103AM02 Datasheet - Page 4

no-image

SR103AM02

Manufacturer Part Number
SR103AM02
Description
Relay; SSR; Sfty; 2 NC, 3 NO, 1 NC; Cur-Rtg 3A; Ctrl-V 115AC; Vol-Rtg 230AC
Manufacturer
Sti (Scientific Technologies, Inc.)
Datasheet

Specifications of SR103AM02

Contact Form
3PDT, SPST-NC
Current, Rating
3 A
Function
Safety
Mounting Type
DIN Rail
Relay Type
Solid State
Standards
cULus, UL, CE, VDE
Voltage, Control
115 VAC
Voltage, Rating
230 VAC
Specifications are subject to change without notice.
Note: The safety contacts of the Omron STI switches are described as normally closed (N/C)—i.e., with the guard closed, actuator in place, and the
model
SR103AM01
SR103AM02
SR103AM03
*230 VAC units are available on special order. Minimum quantities may apply.
electrical
mechanical
environmental
compliance
Specifications
Ordering
Power Supply:
Power consumption:
Safety inputs:
max input resistance:
Outputs:
Output rating Ac:
Output rating Dc:
min Switched current/Voltage:
impulse Withstand Voltage:
max Drop-Out time:
max Output fuse:
reset mode:
contactor monitoring:
mounting:
case material:
max Wire Size:
Weight:
color:
external Switches:
indication:
mechanical life:
enclosure Protection:
Operating temperature:
humidity:
Standards:
Approvals/listings:
Safety category:
machine able to be started.
24 VAC/DC
230 VAC*
115 VAC
Supply
All models
±10%, 50-60 Hz
Approx. 1 VA
1 N/C or 2 N/C or 2 solid state (light curtain)
800 Ohms per channel
3 N/O + 1 N/C auxiliary
Inductive AC-15, 3 A/230 VAC
Inductive DC-13, 2 A/24 V
10 mA/10 V
2500 V
12 ms (75 ms by removing supply voltage)
6 A quick-acting or 4 A slow-acting
Monitored manual (S11-S21) or automatic/manual (S12-S21)
N/C loop S11/S12-S21
35 mm (1.38 in.) DIN rail
Fiber-filled Polyamide PA6.6
1 x 2.5 mm
230 g (8.1 oz.)
Red
None
Green = K1 Closed, Green = K2 Closed
1 x 10
IP20 terminals, IP40 (NEMA 1) housing
24 VAC/DC: -15 to 40°C (5 to 104°F)
115/230 VAC: -15 to 40°C (5 to 104°F)
93% RH at 104°C (219°F)
EN 60204-1, EN 954-1, VDE 0113-1
CE marked for all applicable directives, UL and C-UL, BG
Cat. 4 per EN954-1 (SR103 internal operation)
inputs
2 N/C
2 N/C
2 N/C
7
operations
2
(14 AWG) stranded
Sr103Am01
24 VAC/DC
Outputs
3 N/O
3 N/O
3 N/O
Sr103Am02
115 VAC
Auxiliary
1 N/C
1 N/C
1 N/C
Sr103Am03
230 VAC
SR103AM
44510-1031
44510-1032
44510-1033
Part no.
H