E2E-X2Y1-US Omron Automation, E2E-X2Y1-US Datasheet
E2E-X2Y1-US
Specifications of E2E-X2Y1-US
Related parts for E2E-X2Y1-US
E2E-X2Y1-US Summary of contents
Page 1
... Standard Proximity Sensor E2E Additions to the Series Standard Sensors for Detecting Ferrous Metals under Standard Conditions ■ Wide array of variations. Ideal for a variety of applications. ■ Lineup includes models with pre-wired connectors that use highly oil-resistant cables ■ Lineup includes models with 3-mm diameter and sensing distance of 0.6 mm ■ ...
Page 2
... Connector Models E2E-X@D@-M1(G) E2E-X@E@-M1 E2E-X@Y@-M1 Pre-wired Connector Models E2E-X@D1-M1(G)J(-T) Smartclick Pre-wired Connector Models E2E-X@D@-M1TGJ-U Models with Highly Oil-resistant Cables E2E-X@D@-U Robotics Cable Models E2E-X@D1-R E2E-X@E1-R Models with a different frequency (NO Models only) E2E-X@@15 DC 2-Wire Models E2E-X@D@ DC 3-Wire Models E2E-X@E@ ...
Page 3
... Features Additions to the Series Proximity Sensors with Highly Oil-resistant Cables added to the lineup with the E2E-@-U Oil Resistance Oil Resistance Oil Resistance Oil Resistance (Insulation service life): twice or three times that of oil-resistant vinyl chloride Models with Smartclick pre-wired connectors added to the E2E-@-U Series ...
Page 4
... Models with robotics cables are also available. Add "-R" to the end of the model number (example: E2E-X4MD1-R). The model number E2E-X2D1-N, however, becomes E2E-X2D1-R. *3. Models are also available with 5-m cables. Add the cable length to the model number (example: E2E-X3D1-N 5M). DC 2-Wire, Connector Models (Models with self-diagnostic function are 3-wire.) ...
Page 5
... The standard cable length is 300 mm. Models are also available with 500 mm and 1 m cables. * Refer to page 19 for details. Connector Pin Assignments of DC 2-Wire Models • The connector pin assignments of each New E2E DC 2-Wire Model conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have been changed in comparison to the previous models.) • ...
Page 6
... Models with robotics cables are also available. The model numbers are E2E-X @E1-R (example: E2E-X5E1-R). *3. Models with different frequencies are also available. The model numbers are E2E-X @E@5 (example: E2E-X5E15). *4. These models are also available with e-CON connectors (0.3-m cable). Add "-ECON" to the end of the model number (example: E2E-X2E1-ECON). DC 3-Wire, Connector Models ...
Page 7
... M18 M30 *1. Models with different frequencies are also available. The model numbers are E2E-X @Y@5 (example: E2E-X5Y15). *2. Models are also available with 5-m cables. Add the cable length to the model number (example: E2E-X2Y1 5M). AC 2-wire, Connector Models Connec- Appearance Sensing distance ...
Page 8
... Accessories Instruction manual *1. Use the E2E within the range in which the setting indicator (green LED (except D2 Models). *2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. ...
Page 9
... E2E-X@E@/F@ DC 3-Wire Models Size M8 Shielded Shielded Unshielded Model E2E E2E Item -X1R5E@/F@ -X2ME@/F@ 1.5 mm ±10 ±10% Sensing distance Set distance 1.6 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 13 and 14.) ...
Page 10
... E2E-C@C/B@ and E2E-X1C/B@ DC 3-Wire Models Size 3 dia. Shielded Item Model E2E-CR6C/B@ 0.6 mm ±15% Sensing distance Set distance 0 to 0.4 mm Differential travel 15% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 14.) Iron, 3 × 3 × ...
Page 11
... E2E-X@Y@ AC 2-Wire Models Size M8 Shielded Shielded Unshielded Item Model E2E-X1R5Y@ E2E-X2MY@ 1.5 mm ±10 ±10% Sensing distance Set distance 1.6 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 14.) ...
Page 12
... Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset. M12 M18 Shielded E2E-X3T1 E2E-X7T1 7 mm ±10 5.6 mm Iron, 18 × 18 × 0.5 kHz 2 10 times each and Z directions Approx. 140 g E2E M30 E2E-X10T1 10 mm ±10 Iron, 30 × 30 × 0.4 kHz Approx. 190 g 12 ...
Page 13
... Polarity: None 4 Load +V Prox imity Sensor main circuit (+V) Note 1. The load can be connected to either the + side. 2. The E2E-X@D1-M1J-T has no polarity. Therefore, terminals 3 and 4 have no polarity. 1 Load +V Brown Prox- imity Sensor main circuit Blue Note: The load can be connected to either the + side. ...
Page 14
... E2E-X@D1-M1J-T 3 E2E-X@E/F1-M1 9 E2E-X@D1-M1 2 E2E-X@D2-M1 7 E2E-X@D2-M1(G) 6 E2E-X@D1S-M1 5 E2E-X@Y1-M1 11 E2E-X@Y2-M1 12 E2E-X@D1-M1G 1 E2E-X@D1-M1GJ E2E-X@D1-M1J-T 3 E2E-X@E/F1-M1 9 E2E-X@D1-M1 2 E2E-X@D2-M1 7 E2E-X@D2-M1(G) 6 E2E-X@D1S-M1 5 E2E-X@Y1-M1 11 E2E-X@D1-M1G 1 E2E-X@D1-M1GJ E2E-X@D1-M1J-T 3 E2E-X@E/F1-M1 9 E2E-X@D1-M1 2 E2E-X@D2-M1 7 E2E-X@D2-M1(G) 6 E2E-X@D1S-M1 5 E2E-X@Y1-M1 11 E2E-X@D@-M1TGJ-U 13, 14 E2E-X@D1-M3G 4 E2E-X@D2-M3G 8 E2E-X@E/F1-M3 10 E2E-X@D1-M3G 4 E2E-X@D2-M3G 8 E2E-X@E/F1-M3 10 E2E-X@D1-M3G 4 E2E-X@D2-M3G 8 E2E-X@E/F1-M3 10 E2E-X@D1-M3G 4 E2E-X@D2-M3G 8 E2E-X@E/F1- ...
Page 15
... G: 5-m cable 1: Straight E2E 2: L-shape XS2F-D42@-@C0-A D: 2-m cable G: 5-m cable 1: Straight E2E 2: L-shape XS3F-M42@-40@-R 2: 2-m cable 5: 5-m cable 1: Straight E2E 2: L-shape XS2F-D42@-@80-A D: 2-m cable G: 5-m cable 1: Straight E2E 2: L-shape XS2F-D42@-@80-A D: 2-m cable G: 5-m cable 1: Straight E2E 2: L-shape ...
Page 16
... XS3F-M42@-40@-R 2: 2-m cable 5: 5-m cable 1: Straight E2E 2: L-shape XS2F-A42@-@B0-A D: 2-m cable G: 5-m cable E2E XS2F-A421-@90-A D: 2-m cable G: 5-m cable E2E-X @ -M1TGJ XS5F-D421-@80-P D: 2-m cable G: 5-m cable E2E-X @ -M1TGJ XS5F-D421-@80-P D: 2-m cable G: 5-m cable E2E Connections XS2F 1 1 ...
Page 17
... The cable can be extended up to 200 m (separate metal conduit). *2. D Models: Operation indicator (red) and setting indicator (green), E/F Models: Operation indicator (red) Diagram 8 E2E-X2MY@ 15 dia 6.1 dia × Insulator Diagram 10 E2E-X8MD@ 5.9 E2E-X5ME@/ dia. 15.6 Connector: Product code 17 37104-3163-000FL (Sumitomo 3M dia ...
Page 18
... Insulator diameter: 1.9 mm), Standard length The cable can be extended (separate metal conduit 200 m for the control output and up to 100 m for the diagnostic output. *2. D/T Models: Operation indicator (red), Setting indicator (green) E/F/Y Models: Operation indicator (red) Diagram 12 E2E-X5MY@ 21 dia dia. ...
Page 19
... The cable can be extended (separate metal conduit 200 m for the control output and up to 100 m for the diagnostic output. *2. D/T Models: Operation indicator (red), Setting indicator (green) E/F/Y Models: Operation indicator (red) M8 Connector Models (Unshielded) Diagram 29 E2E-X4MD@-M3G/E2E-X2ME1-M3/F@ 15 dia Models: Operation indicator 6.1 dia. ...
Page 20
... Diagram 20 E2E-X3D@-M1(G) E2E-X2E1-M1/ dia Indicators * M12 × 1 Two clamping nuts Toothed washer * D Models: Operation indicator (red), Setting indicator (green) E/F Models: Operation indicator (red) Diagram 22 E2E-X2Y@- dia M12 × 1 Two clamping nuts Toothed washer Diagram 24 E2E-X7D@-M1(G)/E2E-X5E1-M1 E2E-X5Y@- dia ...
Page 21
... Pre-wired Connector Models (Shielded) Diagram 30 E2E-X2D1-M1TGJ-U *3 Diagram 31 E2E-X3D1-M1GJ E2E-X3D1-M1J-T E2E-X3D1-M1TGJ-U *3 Diagram 33 E2E-X7D1-M1GJ E2E-X7D1-M1J-T E2E-X7D1-M1TGJ-U *3 Diagram 35 E2E-X10D1-M1GJ E2E-X10D1-M1J-T E2E-X10D1-M1TGJ-U *3 Pre-wired Connector Models (Unshielded) Diagram 32 E2E-X8MD1-M1GJ Mounting Hole Dimensions Dimension F (mm dia Indicators *2 M8 × 1 Two clamping nuts Toothed washer dia Indicators *2 M12 × 1 ...
Page 22
... Diagram 34 E2E-X14MD1-M1GJ Diagram 36 E2E-X20MD1-M1GJ Dimensions for Proximity Sensors with Sensor I/O Connectors Shielded Models Unshielded Models Straight Connectors Straight Connectors L1 L-shape Connectors L-shape Connectors L2 Accessories (Order Separately) Sensor I/O Connectors Refer to Introduction to Sensor I/O Connectors for details. Mounting Brackets Protective Covers Sputter Protective Covers Refer to Y92@ for details ...