GLM65A SL Power ( Ault / Condor ), GLM65A Datasheet

no-image

GLM65A

Manufacturer Part Number
GLM65A
Description
Power Supply; 90 to 264 VAC; 65 W; lt2 A; 80 % (Typ.); .0 V; 12 V; -12 V;
Manufacturer
SL Power ( Ault / Condor )
Type
Medicalr
Datasheet

Specifications of GLM65A

Brand/series
GLM65 Series
Configuration
Open-Frame
Efficiency
80 % (Typ.)
Mounting Type
Panel
Number Of Outputs
3
Operation
Switching
Output
-12 VDC @ 3 A, +5 VDC @ 7 A, +12 VDC @ 2.5 A
Power, Output
65 W
Power, Rating
65 W
Primary Type
AC-DC
Standards
UL2601-1, CSA 22.2 No. 601.1, EN60601-1 Approved
Temperature Coefficient
0.03%⁄°C (Typ.)
Temperature, Operating
0 to 50 °C
Voltage, Input
90 to 264 VAC
Voltage, Output
-12, +5, +12 VDC
Voltage, Output 1
+5.0 V
Voltage, Output 2
12 V
Voltage, Output 3
-12 V
Weight
6.5 Oz.
38
SPECIFICATIONS:
Ac Input
90-264 Vac, 47-63 Hz single phase
Output Power
Total continuous output power is 60 W, 75 W peak for 60 s
10% duty cycle. Total continuous rating with 150 LFM of
air is 70 W.
Input Current
Units are exempt from input current harmonic require-
ments of EN61000-3-2 when output power is less than
62W. Maximum input current at minimum input voltage
and output overload will be less than 2.0 A.
Inrush Current
Inrush is limited by internal thermistor. The inrush at 240
Vac, averaged over the first ac half-cycle under cold start
conditions will not exceed 37 A.
Input Protection
Internal AC fuse provided on all units. Designed to blow
only if a catastrophic failure occurs in the unit -- Fuse
does not blow on short circuit or unsustained overload.
Holdup Time
Output voltage stays within regulation for 20 ms from loss
of ac input at 65 W load, from 120 Vac input.
Efficiency
80% typical.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit and will
automatically recover after removal of fault.
Overvoltage Protection
Built in with firing point set. OVP firing reduces output to
less than 50% of nominal voltage in less than 50 ms.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential
mode. Measured with scope probe directly across output
terminals of the power supply with load terminated with
1µF capacitor.
Transient Response
Main Output - 500 µs typical response time for return to
within 0.5% of final value for a 50% load step within the
regulation limits of minimum and maximum load, i/ t<
0.2 A/µs. Maximum voltage deviation is 3.5%.
GLC65
65 Watt Multiple Output Global Performance Switchers
Commercial/GLM65 Medical
FEATURES:
• 65 Watt Wide Range Input
• High Efficiency (Up to 90%)
• Universal input 90-264 Vac
• 2-year warranty
• Also available in single outputs
• Conducted EMI exceeds FCC Class B and CISPR 22
• Exempt from line harmonics standard EN61000-3-2
• Commercial Approved to UL1950, CSA-C22.2 No. 950,
• Medical Approved to UL2601-1, CSA 22.2 No. 601.1,
Minimum Load
No minimum load required on any output. However,
regulation limits may be exceeded if extreme conditions
are applied. Contact factory for assistance.
Temperature Coefficient: 0.03%°C typical on all outputs.
Voltage Adjustment
Units provided with potentiometer capable of a minimum
adjustment range of +/- 5% from nominal setting.
EMI / EMC Compliance:
All models include built-in EMI filtering to meet the EMC
requirements of IEC601-1-2.
Performance
Conducted Emissions GLC65 EN55022, Class B; FCC Class B
Conducted Emissions GLM65 EN55011, Class B; FCC Class B
Static Discharge
RF Field Susceptibility
Fast Transients / Bursts
Surge Susceptibility
Conducted RF Susceptibility
Voltage Sags & Surges
Line Frequency Harmonics
GLC65 Commercial - Safety
Condor DC Power Supplies, Inc. declares under our sole
responsibility that all models are in conformity with the
applicable requirements of EN60950 following the
provisions of the Low Voltage Directive 73/23/EEC. All
models are approved to UL1950 (with no D3 deviations),
CSA22.2 No. 950-95 3rd edition, Level 3, IEC950,
EN60950. CB certificate available.
Commercial Leakage Current
Less then 500 µA @ 120 Vac. Less then 1.2 mA @ 240 Vac.
GLM65 Medical - Safety
Approvals: All models are certified to be in compliance
with the applicable requirements of UL2601-1, CSA 22.2
No. 601.1, IEC 601-1 (1988), EN 60601-1: 1990.
Medical Leakage Current
40 µA under normal conditions (132 Vac @ 60 Hz).
Maximum under single fault conditions (264 Vac @ 60
Hz) is 170 µA.
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
EN60950
and EN60601-1
marked to LVD
EMC Standard
EN61000-4-3, Level 3
EN61000-4-5, Level 3
EN61000-4-11
EN61000-3-2 Class A (>62Wout)
EN61000-4-2, Level 3
EN61000-4-4, Level 3
EN61000-4-6, 3V, 80%
Exempt (<62Wout)