AM1R-D3-AC07D-A-10-2 Eaton / Circuit Breakers, AM1R-D3-AC07D-A-10-2 Datasheet - Page 4

no-image

AM1R-D3-AC07D-A-10-2

Manufacturer Part Number
AM1R-D3-AC07D-A-10-2
Description
Circuit Breaker; Hyd/Mag; Togl; Cur-Rtg 10A; Panel; 1 Pole; Vol-Rtg 250VAC
Manufacturer
Eaton / Circuit Breakers
Type
Hydraulic/Magneticr
Datasheet

Specifications of AM1R-D3-AC07D-A-10-2

Actuator Type
Toggle
Brand/series
AM/R Series
Current, Rating
10 A
Dimensions
2.02"Lx0.75"Wx2.5"H
Mounting Type
Panel
Number Of Poles
1
Termination
Screw
Voltage, Rating
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
AML CATALOG NUMBERING SYSTEM
TYPICAL DIMENSIONS
0
N/A 8X 18X 25X
Select from 1 to 8 poles, and enter the number in position 3 of the catalog number. For example, an AM3L would identify a 3-pole AML breaker.
On multi-pole breakers, Steps 2 and 3 can be repeated if subsequent poles are different than the first. Identification starts from left-hand side when
viewing the front of the breaker.
These will provide standard handle locations. For additional options, contact the Technical Resource Center.
Enter the whole number current rating. For example, use code “15” for a 15 A current rating. For fractional amperages, use an “R” to
designate the decimal point. For 0.10 A, enter the code “ R10.”
Specific data on trip curves can be found on the Web at www.EatonElectrical.com/heinemann.
Up to 277 Vac.
Internal Circuit Type and Inrush Catalog Code
OFF
ON
31º(5º
1
31º(5º
0
1 = 1-Pole
2 = 2-Pole
3 = 3-Pole
4 = 4-Pole
5 = 5-Pole
6 = 6-Pole
7 = 7-Pole
8 = 8-Pole
2
3
5
6
7
15
16
98
99
(10.3)
of Poles
0.41
Number
9
8
22
23
27
25
26
(16.7)
0.66
(13.1)
0.52
39
38
32
33
37
A = 50/60 Hz
B = dc
C = 400 Hz
D = 50/60 Hz/dc
Switch Only
Series Trip w/Auxiliary
Series Trip
Shunt-Tap
Relay Trip
Dual Rating
DuCon
DuCon Series+Relay
Mid-Trip
Mid-Trip w/Alarm Switch
Frequency
Internal Circuit
(4.6)
0.18
(51.7)
2.04
Length of Black Wire Specified by Customer
(3.5)
0.14
Else Supplied 12 Inches (304.8 mm) Long
NO
NC
C
DE = Multi-Pole Breakers
050
054
058
062
Yellow/
066
AE = Single-Pole Breakers
Green/
Green
Red
Red
AM3L A 2 AE 050 07 DDU 07 15 1
(49.3)
1.94
LOAD
Handle Location
LINE
0.28
(7.1)
051
055
059
063
067
Yellow
Green/
Green
Green
Illumination Catalog Code
Black Wire
Red/
Negative LED
Voltage Here
Positive LED
Black Wire
Voltage to
Connect
Connect
1.300
MAX
Two-Position
Two-Position
One-Position
&
052
056
060
Yellow/
064
068
Yellow
Yellow
Blue
Red/
053
057
061
065
Yellow/
069
Yellow
Blue/
Blue
Red
WNU = CE
OFF
ON
Mid Trip
ON/OFF
ON/OFF
Position
Position
Position
DNU = None
DDU = UL 489
DA = UL 1077
TA = TUV/UL 1077
Approval Code
EATON CORPORATION Frame Information — AMR Series
Slot Positioned Left, Center or
Slot Positioned Left or Right,
0.156
Holes
Holes Spaced 0.750" Apart
(36.8)
Two
DIA
Per Pole Mounting Holes
Right, Per Pole Mounting
1.45
1-Pole Panel Cutout
Spaced 0.750" Apart
2-Pole Panel Cutout
3-Pole Panel Cutout
Imperial Metric
07
97
08
98
21
23
25
31
Terminals/Mounting Catalog Code
(19.3)
0.76
13
14
15
16
20
22
24
30
R02
R25
R50
1
2R5
5
7R5
10
15
20
25
30
50
60
80
100
(23.0)
Code
0.91
Current Rating
10-32 Threads (70 A)
1/4-20 Threads (100 A)
M5 Threads (70 A)
M6 Threads (100 A)
Plug-in 7.77 x 16.6
Plug-in 6.25 x 21.6
Plug-in 6.25 x 15.4
Fuse Clip
(52.4)
2.06
(Amperes)
0.02
0.25
0.50
1
2.5
5
7.5
10
15
20
25
30
50
60
80
100
Current
Terminals
(63.5)
2.50
(28.6)
1.13
P = Instant
1 = Long Delay 8X Inrush
2 = Medium Delay 8X Inrush
3 = Short Delay 8X Inrush
4 = Long Delay 18X Inrush
5 = Medium Delay 18X Inrush
6 = Short Delay 18X Inrush
7 = Long Delay 25X Inrush
8 = Medium Delay 25X Inrush
9 = Short Delay 25X Inrush
S= Switch Only
07 = NO-NC 4.8 Fast-on
52 = NO-NO 2.8 Fast-on
53 = NO-NC 2.8 Fast-on
Auxiliary Switch Options
(19.0)
0.75
Curve
(23.0)
0.91
(52.4)
2.06
23