ADA600F-48 Cosel U.S.A. Inc., ADA600F-48 Datasheet - Page 2

no-image

ADA600F-48

Manufacturer Part Number
ADA600F-48
Description
Power Supply; 48 V; 6.5 A @ 100 V; 85 to 264; 300 mV (Max.); 192 mV (Max.)
Manufacturer
Cosel U.S.A. Inc.
Datasheet

Specifications of ADA600F-48

Brand/series
ADA Series
Configuration
Enclosed
Current, Output
6.5 A @ 100 V
Frequency, Operating
50⁄60 Hz
Line Regulation
192 mV (Max.)
Load Regulation
300 mV (Max.)
Mounting Type
Panel
Number Of Outputs
1
Operation
Linear
Output
48 VDC @ 12.5 A
Primary Type
AC-DC
Special Features
PFC
Standards
UL60950, cUL (CSA60950), EN60950, EN50178 Complies with DEN-AN and IEC60950 (At only AC input)
Temperature, Operating
-10 to 71 °C
Time, Response
500 mS (Max.)
Voltage, Input
85 to 264/120 to 350 VAC/VDC
Voltage, Output
48 VDC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADA600F-48
Manufacturer:
COSEL
Quantity:
668
ADA
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
SPECIFICATIONS
Please refer to derating curve, because the rated load current depends on cooling method that is convention cooling or forced air.
*1
*2
*3
A-120
The value is primary surge.The current of input surge to a built-in noise filter (0.2ms or less) is
excluded.
Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown
in Instruction Manual 2.3.
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
R
MODEL
VOLTAGE[V]
FREQUENCY[Hz]
EFFICIENCY[%]
POWER FACTOR
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV] 0 to +50 C 240max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.6 - 27.0
OUTPUT VOLTAGE SETTING[V] 23.5 - 24.5
OVERCURRENT PROTECTION Works over 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
ALARM OUTPUT
REMOTE ON/OFF ( RC )
INPUT-OUTPUT - RC
INPUT-FG
OUTPUT - RC-FG
OPERATING TEMP. , HUMID.AND ALTITUDE -10 to +71 C , 20 - 90%RH ( Non condensing ) ( Refer to DERATING CURVE ), 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -20 to +75 C , 20 - 90%RH ( Non condensing ), 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
ADA600F
Unit type
ACIN 100V 84typ ( Io=100% )
ACIN 200V 86typ ( Io=100% )
ACIN 100V 0.99typ ( Io=100% )
ACIN 200V 0.98typ ( Io=100% )
ACIN 100V
ACIN 200V
ACIN 100V
ACIN 100V
ACIN 200V
ACIN 200V
0 to +50 C
-10 - 0 C
0 to +50 C
-10 - 0 C
* 1
* 1
* 2
* 2
* 2
* 2
* 3
* 3
* 3
* 3
* 4
* 5
* 5
ADA600F-24
AC85 - 264 1 f or DC 120 - 350 ( AC64 or DC90 optionally available * 6 )
50/60 ( 47 - 63 ) or DC
20typ ( Io=100% ) ( More than 3sec.to re-start )
40typ ( Io=100% ) ( More than 3sec.to re-start )
0.75max ( 60Hz , According to IEC60950 and DEN-AN ) ( Io=100% )
24
14 ( Peak 25 ) convection
21 ( Peak 25 ) forced air
15 ( Peak 31 ) convection
25 ( Peak 31 ) forced air
96max
150max
120max
160max
150max
180max
96max
500max ( ACIN 100V , Io=100% )
20typ ( ACIN 100V , Io=100% )
31 - 34.5
LED ( Green )
Detecting low input voltage ( PF ), detecting low output voltage ( LV ) . ( Optional : -W , refer to Instruction Manual 5 )
Requirement for external source ( Option : -R , refer to Instruction Manual 5 )
AC3 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( At Room Temperature )
10 - 55Hz , 19.6m/s
196.1m/s
UL60950-1 , C-UL ( CSA60950-1 ), EN60950-1 , EN50178 Complies with DEN-AN and IEC60950-1 ( At only AC input )
Complies with FCC-B , CISPR22-B , EN55022-B , VCCI-B
Low Voltage Directive , EMC Directive
Complies with IEC61000-3-2
65 X 127 X 195mm ( W X H X D ) ( without terminal block ) /1.5kg max
Convection/Forced air
2
( 20G ), 11ms , once each X , Y and Z axis
2
( 2G ), 3minutes period , 60minutes each along X , Y and Z axis
ADA600F-30
86typ ( Io=100% )
87typ ( Io=100% )
30
11 ( Peak 20 ) convection
16.5 ( Peak 20 ) forced air
12 ( Peak 24.5 ) convection
20 ( Peak 24.5 ) forced air
120max
180max
160max
230max
190max
250max
300max
120max
27.0 - 33.0
29.0 - 31.0
40 - 48
*4
*5
*6 Derating is required.Consult us for details.
*
1
KEISOKU-GIKEN: RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
Applicable when remote control (optional) is added.
A sound may occur from power supply at pulse loading.
ADA 600
Ordering information
2
ADA600F-36
86typ ( Io=100% )
87typ ( Io=100% )
36
9 ( Peak 16.5 ) convection
14 ( Peak 16.5 ) forced air
10 ( Peak 20.5 ) convection
16.5 ( Peak 20.5 ) forced air
144max
240max
200max
260max
230max
280max
360max
144max
33.0 - 41.0
35.0 - 37.0
51 - 60
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
Recommended Noise Filter
NAC-20-472
3
F
4
-24
ADA600F-48
86typ ( Io=100% )
89typ ( Io=100% )
48
6.5 ( Peak 12.5 ) convection
10.5 ( Peak 12.5 ) forced air
7 ( Peak 15.5 ) convection
12.5 ( Peak 15.5 ) forced air
192max
300max
200max
300max
250max
400max
480max
192max
41.0 - 52.8
47.0 - 49.0
64 - 76
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
Specification is changed at
option,refer to Instruction
Manual.
G :Low leakage current
E :Low leakage current
F :with Fan unit(only -24)
T :Vertical terminal block
J :Connector type
C :with Coating
R :Remote ON/OFF
N1:DIN rail
W:Alarms and Redundant
5
and EMI class A
operation
-O

Related parts for ADA600F-48