Specifications of U1253B

Accuracy
DC 0.025%
Color, Body
Orange
Current, Range
10 a
Display Resolution
50,000 (Both)
Display Type
Dual
Frequency Range
20 MHz
Includes
Standard Test Leads (with 19-mm and 4-mm tips), Alligator Clips, Battery Charger (for U1252B), Certificate of Calibration, Test Report, Quick Start Guide
Interface
IR to USB
Protection Class
CAT III 1000 V and CAT IV 600 V
Voltage, Range, Ac
1000 V
Oled Display With 160° Viewing Angle And 2000
1 contrast ratio for extra clear readings
U1163A SMT grabbers
• One pair of SMT grabbers (red and black).
• Rated CAT II 300 V, 3 A.
MEASURING ACCESSORIES (NON-TEMPERATURE)
U1168A Standard test lead kit
Includes two test leads (red and black), 19-mm and 4-mm test
probes, alligator clips, fi ne-tip test probes, SMT grabbers and
mini grabber (black).
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probes (19-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
• Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
• Alligator clips: CAT III 1000 V, 10 A
• Fine-tip test probes: CAT II 300 V, 3 A
• SMT grabber: CAT II 300 V, 3 A
• Mini grabber: CAT II 300 V, 3 A
MEASURING ACCESSORIES (TEMPERATURE)
U1180A Thermocouple adapter+lead kit, J and K
types
Includes thermocouple adapter, thermocouple bead J-type and
thermocouple bead K-type.
• T/C adapter J/K-type
• T/C bead J-type: –20 °C to 200 °C
• T/C bead K-type: –20 °C to 200 °C
U1183A Air temperature probe
• Type-K T/C for use in air and non-caustic gas
• Measurement range: –50 ºC to 800 ºC
• Includes adapter U1184A for connection to DMM
(highly recommended for CAT IV environment)
Recommended for use with Agilent standard test leads.
U1164A Fine-tip test probes
• One pair of fi ne-tip test probes (red and black).
• Rated CAT II 300 V, 3 A.
U1169A Test probe leads
Includes two test leads (red and black), and a pair each of
19-mm and 4-mm test probes.
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probes (19-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
• Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
U1181A Immersion temperature probe
• Type-K T/C for use in oil and other liquids
• Measurement range: –50 °C to 700 ºC
• Includes adapter U1184A for connection to DMM
U1184A Temperature probe adapter
• Mini-connector-to-banana-plug adapter for use with DMM
(highly recommended for CAT IV environment)
Recommended for use with Agilent standard test leads.
11
U1165A Test probe leads
• Rated CAT III 1000 V, 15 A
U1583B AC current clamp
• Dual range: 40 A and 400 A
• Rated CAT III 600 V
• BNC-to-banana-plug adapter provided for use with DMMs
U1182A Industrial surface temperature probe
• Type-K T/C for use on still surfaces
• Measurement range: –50 ºC to 400 ºC
• Includes adapter U1184A for connection to DMM
U1185A J-type thermocouple and adapter
• T/C adapter J/K-type
• T/C bead J-type: –20 °C to 200 °C