GPC41-24G SL Power ( Ault / Condor ), GPC41-24G Datasheet - Page 2

no-image

GPC41-24G

Manufacturer Part Number
GPC41-24G
Description
SWITCHING POWER SUPPLY, SINGLE OUTPUT, WIDE RANGE, COMMERCIAL, 40 WATTS
Manufacturer
SL Power ( Ault / Condor )
Type
Commercialr
Datasheet

Specifications of GPC41-24G

Brand/series
GPC41 Series
Configuration
Open-Frame
Mounting Type
Panel
Number Of Outputs
1
Operation
Switching
Output
24 VDC @ 1.7 A
Power, Output
41 W
Primary Type
AC-DC
Voltage, Input
85 to 264 VAC
Voltage, Output
24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Note:
A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output
current and total output power by 2.5% per °C above 50°C. For operation in a confined space, moving air may be required. Under
all conditions, the cooling vs. load profile should be such that heat sinks and/or heatsink temperatures do not exceed 90 °C for
extended periods.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating
and 1 hr./axis non-operating.
Commercial
Model
GPC41-5
GPC41-12
GPC41-15
GPC41-24
GPC41-28
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
GPC41/GPM41 MECHANICAL SPECIFICATIONS
Add “G” suffix to model number for RoHS compliant model.
3
Medical
Model
GPM41-5
GPM41-12
GPM41-15
GPM41-24
Output
5.1 V
12 V
15 V
24 V
28 V
OPERATING
See individual specs.
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
pk
Current
rms’
6.0 A
3.3 A
2.7 A
1.7 A
1.4 A
0.003 g
2
/Hz
Minimum
Load
0.15
0.03
0.03
0.01
0.01
3
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
Regulation
rms’
pk
0.75%
0.75%
0.75%
0.75%
0.75%
Load
0.026 g
2
/Hz
Initial Setpoint
Tolerance
2%
2%
2%
2%
2%
6.2 ± 0.6 V
14 ± 1.0 V
19 ± 1.5 V
34 ± 2.8 V
28± 2.5 V
Setpoint
OVP
Ripple and
Noise
1%
1%
1%
1%
1%

Related parts for GPC41-24G