ES7300 Chemtronics, ES7300 Datasheet

no-image

ES7300

Manufacturer Part Number
ES7300
Description
Chemical, Contact Cleaner, Non-Ozone Depleting, 12 Oz Aerosol Can
Manufacturer
Chemtronics
Type
Contactr
Datasheet

Specifications of ES7300

Boiling Point
90 °F
Chemical Component
1, 1, 1, 2-Tetrafluoroethane/Cirozane™/Methylcyclohexane/n-Propanol/Trans-1, 2-Dichloroethylene
Dispensing Method
Aerosol
Evaporation
> 1
Flash Point
None to boiling (TCC)
Odor
Ethereal
Ph
NA
Physical State
Clear, Colorless Liquid
Pressure, Vapor
220 mmHg @ 70 °F
Primary Type
Cleaner
Solubility
Negligible
Specific Gravity
1.50
Volatile
100 %
Weight
12 Oz.
Lead Free Status / Rohs Status
RoHS Compliant part Hazardous Materials
CHEMTRONICS
Technical Data Sheet
PRODUCT DESCRIPTION
Pow-R-Wash
is a highly effective nonflammable solvent
cleaner for electrical and electronic contacts
and assemblies.
solvent
Chemtronics’ unique HFE technology, to
quickly remove oils, oxides, and other
contaminants from metal contacts. Cirozane
Contact Cleaner is specially engineered to
restore and improve electrical continuity on
energized equipment.
TYPICAL APPLICATIONS
Pow-R-Wash
deoxidizes:
MIL-PRF-29608A (AS) Class C approved
Removes encrusted oxides, dirt, grease and
other contaminants from contacts
Nonflammable
Noncorrosive and safe for plastics
Evaporates quickly without residue
Excellent dielectric strength
Penetrates to clean hard to reach areas
Contains no ozone depleting substances
Contacts and Relays
Plugs and Sockets
Circuit Breakers
Motors and Generators
Finger and Edge Connectors
Selector Switches
Fuses
system
CZ Contact Cleaner cleans and
CZ electronics contact cleaner
This non-ozone depleting
utilizes
®
Electronics Contact Cleaner
Pow-R-Wash
Cirozane
,
TYPICAL PRODUCT DATA AND
PHYSICAL PROPERTIES
Boiling Point
Specific Gravity
Flash Point (TCC)
Evaporation Rate (butyl acetate=1)
Surface Tension
(dynes/cm @ 25°C)
Solubility in Water
Kauri-Butanol (KB) Number
Dielectric Breakdown
(ASTM D-877)
VOC* Content:
RoHS Compliant
Shelflife
*Volatile Organic Compound (VOC) information is calculated on a
weight basis using the VOC definition of California Air Resources
Board (CARB) Consumer Product Regulations, South Coast Air Quality
Management District (SCAQMD) Rule 102 and the Federal definition
published in 40 CFR 51.100(s).
COMPATIBILITY
Pow-R-Wash
generally compatible with most materials used
in the electronics industry. However as with
any
compatibility must be determined on a non-
critical area prior to use.
SCAQMD
Federal
CARB
cleaning
CZ
CZ
agent,
Contact
solvent/component
TDS # 7300
Aerosol
99 g/L
None
37%
90°F (Initial)
Negligible
7%
5 years
1.50
31 kV
11.6
40
Cleaner
>1
is

ES7300 Summary of contents

Page 1

... This non-ozone depleting solvent system utilizes Chemtronics’ unique HFE technology, to quickly remove oils, oxides, and other contaminants from metal contacts. Cirozane Contact Cleaner is specially engineered to restore and improve electrical continuity on energized equipment. ...

Page 2

... Spray 4-6 inches from surface to clean. Wash parts from top to bottom, allowing the liquid to flush away dirt and dissolved oil and grease. For precise application use attached extension tube. Compatibility AVAILABILITY Excellent ES7300 Excellent ES7308 Excellent Excellent Excellent Excellent Excellent HCFC-141b ...

Page 3

... ITW CHEMTRONICS SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Information: 800-TECH-401 Product Identification Product Code: ES7300, ES7308, ES7300C, ES7308C SECTION 2: COMPOSITION/INFORMATION ON INGREDIENTS Chemical Name Cirozane™ trans-1,2-dichloroethylene 1,1,1,2-Tetrafluoroethane Methylcyclohexane SECTION 3: HAZARD IDENTIFICATION Emergency Overview: Clear, colorless liquid with faint ethereal odor. This product is nonflammable. Liquid may irritate eyes and skin under repeated or prolonged exposure ...

Page 4

... ITW CHEMTRONICS SECTION 10: STABILITY AND REACTIVITY Stability - This product is stable. Conditions to Avoid: Steam, oxidizers, elevated temperatures. Do not spray near open flames, red hot surfaces or other sources of ignition. Incompatibility: Do not mix with chemically active metals such as potassium, magnesium, zinc and powdered aluminum, strong base, caustic soda, caustic potash or oxidizing ...