H7CXAWD1NDC1224AC24 Omron Automation, H7CXAWD1NDC1224AC24 Datasheet - Page 15

no-image

H7CXAWD1NDC1224AC24

Manufacturer Part Number
H7CXAWD1NDC1224AC24
Description
Counter; Digital; 12-24VDC 24VAC; Contact Output; 6; Screw Terminal; 50/60 Hz
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CXAWD1NDC1224AC24

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
12-24 VDC/24 VAC
Operating Procedures
Setting Procedure Guide
Setting for Counter Operation
Use the following settings.
Setting for Tachometer Operation
Refer to page page 27.
* At the time of delivery, the H7CX is set to the 1-stage preset counter configuration. (2-stage models are set to the 2-stage preset counter configuration.) Refer to page page 35 for information
I/O Functions for Counter Operation
After making DIP switch settings for basic operations, advanced functions can be added using the operation keys.
For details, refer to page page 16.
on switching models.
Note: All pins are factory-set to OFF.
Step1
Step2
When setting functions using the DIP switch, be sure to set pin 1 of the DIP switch to ON.
DIP switch settings are effective when the power is turned ON again. (Perform DIP switch settings while the power is OFF.)
1
2
3
4
5
6
7
8
Run mode
Power ON
DIP switch settings
Counting speed
Input mode
Output mode
Output time
Minimum reset signal
Input selection
Set the basic parameters.
(If the desired I/O mode is not listed below or to set all parameters using the front panel keys, perform
below.)
The H7CX-A@-N is a Counter that contains more than one functional counter.
When using the Counter in any mode other than the default mode*, use the following chart to enter
Configuration Selection Mode and set the functions that are suitable to the application.
* The default mode is 1-stage preset counter configuration (2-stage preset counter configuration for 2-stage models).
Note:
Item
Step2
Hold down for 1 s min.
Hold down for 1 s min.
Key-protect switch
can be performed first, followed by
+
+
1
1
Refer to the table on the right.
Disabled
*
30 Hz
20 ms
selection mode
0.5 s
NPN
OFF
Configuration
UP
*
Enabled
DOWN
0.05 s
5 kHz
1 ms
PNP
ON
OFF
ON
Select the function from Table 1 using the U (D) Key.
Note:
Step1
1 2 3 4 5 6 7 8
(1-stage
preset
counter)
Be sure to set pin 1 to ON.
The configuration that can be selected depends on the model.
.
(2-stage
preset
counter)
Pin 4
OFF
OFF
(Total and
preset counter)
ON
ON
(Batch
counter)
Pin 5
OFF
OFF
ON
ON
(Dual
counter)
(Twin
counter)
twn
Output mode
H7CX-A@-N
K-1
(Tachometer)
N
C
F
Step3
Counter
,
15