MY2IN-AC24(S) Omron Automation, MY2IN-AC24(S) Datasheet - Page 17

no-image

MY2IN-AC24(S)

Manufacturer Part Number
MY2IN-AC24(S)
Description
RELAY; E-MECH; POWER; DPDT; CUR-RTG 5A; CTRL-V 24AC; VOL-RTG 250/125AC/DC; SOCKET MNT
Manufacturer
Omron Automation
Datasheet

Specifications of MY2IN-AC24(S)

Contact Form
DPDT
Current, Rating
5 A
Dimensions
21.5 mm W x 36 mm H x 28 mm D
Function
Power
Mounting Type
Socket
Power, Rating
2500⁄300 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA, VDE, LR, SEV, RoHS
Termination
Plug-In
Voltage, Control
24 VAC
Voltage, Rating
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Examples of Applicable Wires (Confirmed Using Catalog Information)
■ Wiring
Use wires of the applicable sizes specified above. The length of the
exposed conductor should be 8 to 9 mm.
Use the following wiring procedure.
1. Insert the specified screwdriver into the release hole located
Fig. 2 Wire Connection Holes and Release Holes
Wire connection holes
Type of wire
Equipment wire 2491X
BS6004
Switchgear BS6231
Switchgear BS6231
Tri-rated control and switchgear
Conduit
UL1007
UL1015
UL1061
UL1430
Fig. 1 Exposed Conductor Length
Fig. 3 Section A-A of Fig. 2
beside the wire connection hole where the wire is to be inserted.
Release holes
8 to 9 mm
Wire connection hole
Release hole
Conductor type
Flexible
Solid
Flexible
Stranded
Flexible
Flexible
Flexible
Flexible
Solid
Flexible
Screwdriver
Insert
See note 1, above.
0.5 mm
18AWG
18AWG
18AWG
2
2. Insert the exposed conductor into the wire connection hole.
3. Pull out the screwdriver.
Note: Use no more than 2 wires per terminal, 1 wire per hole.
Recommended wire sizes See note 2, above.
0.5, 0.75, 1.0 mm
1.0 mm
0.5, 0.75 mm
0.5, 0.75, 1.0, 1.5 mm
1.5 mm
16AWG
18AWG, 16AWG
16AWG
General-purpose Relay
2
2
2
2
2
Insert
1.5 mm
1.5 mm
1.0 mm
MY
2
2
2
Pull out
275

Related parts for MY2IN-AC24(S)