S8VM-30024C Omron Automation, S8VM-30024C Datasheet

no-image

S8VM-30024C

Manufacturer Part Number
S8VM-30024C
Description
POWER SUPPLY, COVERED, 300 WATT, 24 VOLT, 14A
Manufacturer
Omron Automation
Datasheet

Specifications of S8VM-30024C

Brand/series
S8VM Series
Configuration
Enclosed
Mounting Type
Panel
Number Of Outputs
1
Operation
Switching
Output
24 VDC @ 14 A
Power, Output
300 W
Primary Type
AC-DC
Special Features
Remote Sense
Voltage, Input
100 to 240 VAC
Voltage, Output
24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Power Supply Featuring OMRON’s Unique, New Undervoltage Alarm Function with
Compact Body Contributing to Machine Downsizing
• New undervoltage alarm function assists in determining causes of errors (S8VM-@@@24A@/P@ only).
• Power failure alarm function provides notification of output voltage errors (300-, 600-, and 1,500-W models only).
• Broad range of possibilities with 8 capacities and 29 models to choose from.
• RoHS-compliant
• New, attentive design prevents screws from falling out of terminal block (except for output terminals of 300-, 600-, and 1,500-W
• Finger protection prevents electric shock.
• DIN Rail mounting.
• Safety standards: UL508/60950-1/1604, CSA C22.2 No. 14/No. 60950-1/No. 213, EN50178, EN60950-1 (The 300-, 600-, and
• Conforms to SEMI F47-0200 (when 200-V input is used).
• Harmonic current emissions: Conforms to EN61000-3-2 (except for 15- and 30-W models).
Model Number Structure
■ Model Number Legend
Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 2.
Note: 1. A forced-air cooling method with a fan is used with 300-, 600-, and 1,500-W models.
S8VM- @@@@@@@
1. Power Ratings
2. Output Voltage
Note: Refer to Safety Precautions on page 32.
models).
1,500-W models will not conform to safety standards if the customer replaces the fan.)
Switch Mode Power Supply
S8VM
015:
030:
050:
100:
150:
300:
600:
152: 1,500 W
05: 5 V
12: 12 V
15: 15 V
24: 24 V
2. The housing and terminal of the connector for the undervoltage alarm output are provided with the S8VM-05024A@/P@, S8VM-
3. Bottom mounting models cannot be used for front mounting. For a front mounting configuration, use a DIN Rail Mounting Bracket model
10024A@/P@ and S8VM-15024A@/P@.
or Mounting Brackets (sold separately).
100 W
150 W
300 W
600 W
15 W
30 W
50 W
1
2
3 4
(15/30/50/100/150/300/600/1,500-W Models)
3. Configuration/Functions
4. Configuration
None: Open-frame type Standard type
C:
A:
P:
None:
D:
Covered type
Covered type
Covered type
Bottom mounting type (See note 3.)
DIN Rail mounting bracket type
Standard type
Undervoltage alarm type (Sinking)
(See note 2.)
Undervoltage alarm type (Sourcing)
(See note 2.)
1

Related parts for S8VM-30024C

S8VM-30024C Summary of contents

Page 1

... V Note forced-air cooling method with a fan is used with 300-, 600-, and 1,500-W models. 2. The housing and terminal of the connector for the undervoltage alarm output are provided with the S8VM-05024A@/P@, S8VM- 10024A@/P@ and S8VM-15024A@/P@. 3. Bottom mounting models cannot be used for front mounting. For a front mounting configuration, use a DIN Rail Mounting Bracket model or Mounting Brackets (sold separately) ...

Page 2

... A S8VM-15012C --- --- 10 A S8VM-15015C --- --- 6.5 A S8VM-15024C S8VM-15024A S8VM-15024P 60 A S8VM-30005C --- --- 27 A S8VM-30012C --- --- 22 A S8VM-30015C --- --- 14 A S8VM-30024C --- --- Peak current: 16.5 A (200 VAC) 120 A S8VM-60005C --- --- 53 A S8VM-60012C --- --- 43 A S8VM-60015C --- --- 27 A S8VM-60024C --- --- Peak current (200 VAC (100 VAC) S8VM-15224C --- --- 70 A (200 VAC) (See note 3 ...

Page 3

... and 15 V), 120% to 160% of rated load current (S8VM-30024C), 115% to 160% of rated load current (S8VM- 60024C), voltage drop ( and 24 V), voltage drop, intermittent (5 V), au- tomatic reset Yes (See note 4 ...

Page 4

... S8VM-100@@@@ (100 W) Inrush Harmonic current current protection Rectification suppression circuit AC (L) Fuse Noise INPUT 3.15 A filter AC (N) Drive Drive control circuit Overcurrent detection circuit /FG S8VM-150@@@@ (150 W) Inrush Harmonic current current protection Rectification suppression circuit AC (L) Fuse Noise INPUT 5 A filter AC (N) ...

Page 5

... Bottom Mounting Models S8VM-300@@C Four, M4 (depth: 6 max.) 60±0.5 11 10.5 40±0.5 Note: The image is the S8VM-30024C Model. S8VM-600@@C Four, M5 terminal screws 101.8 Three, M4 terminal screws Note: The image is the S8VM-60024C Model. S8VM-15224C Two, M8 bolts and nuts 126.5 82 Four, M4 terminal screws Note: M8 bolts and nuts for the output terminals are not included. ...

Related keywords