F-40X Triad Magnetics, F-40X Datasheet

no-image

F-40X

Manufacturer Part Number
F-40X
Description
Transformer; Chassis; Pri:115V; Sec:26.8VCT; Sec:1A; Lead; 60Hz; 3-5/16In.In.W; 1-15/16I
Manufacturer
Triad Magnetics
Type
Powerr
Datasheet

Specifications of F-40X

Brand/series
F Series
Configuration
Bobbin
Current, Secondary
1 A
Dimensions
3-5/16"W×1-15/16"H×2"D
Frequency
60 Hz
Length, Lead
7 "
Mounting Hole Centers
2.812 "
Mounting Type
Panel/Chassis
Number Of Outlets
2
Phase
1
Standards
UL
Temperature, Operating
+35 °C
Termination
Leadwires
Voltage, Primary
115 VAC
Voltage, Secondary
26.8 (C.T.) VAC
Weight
1.3 lbs.
Lead Free Status / Rohs Status
RoHS Compliant part
F-40X
Electrical Specifications (@25C)
1. Maximum Power: 26.8 VA
2. Primary: 115V 60 Hz
3. Secondary: 26.8VCT @ 1.00 Amps
4. Voltage Regulation: 15 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-40X is part of a series which has a long history of reliable service in the field,
made from a proven design and constructed with UL recognized materials.
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions:
Mounting Hole Diameter: .187 in
Lead length: 7.0 inches + 1 inch
Weight: 1.30 lbs
Schematic:
Primary:
Secondary: Red to Red
RoHS Compliance:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
1.937
A
3.312
B
Black to Black
2.00
C
As of manufacturing date February 2005, all standard
Units: In inches
2.812
D
BLK
BLK
RED
R/Y
RED
P
Chassis Mount: Single Secondary
O W E R
T
R A N S F O R M E R
BLK
BLK
B
D
A
C
R/Y
RED
RED

Related parts for F-40X

F-40X Summary of contents

Page 1

... Voltage Regulation TYP @ full load to no load 5. Temperature Rise: 35C TYP (45C MAX allowed) Description: The F-40X is part of a series which has a long history of reliable service in the field, made from a proven design and constructed with UL recognized materials. Construction: Wound on a single channel nylon bobbin. Materials are UL recognized, Class B (130º ...

Page 2

... Triad offers a full choice of power supply transformers for direct use or in transformer, rectifier, or filter circuits. Other available secondary voltages include control, filament and low level signaling in standard values. The transformers are single primary with single and multiple secondaries in standard size and weight configurations. ...

Page 3

... No. Volts Amps F-57X 25.2 CT 1.000 F-357X 25.2 CT 1.000 A F-41X# 25.2 CT 2.000 F-341X 25.2 CT 2.000 F-56X 25.2 CT 2.800 F-119X 26.8 CT 0.150 F-40X# 26.8 CT 1.000 B F-340X 26.8 CT 1.000 F-55X 26.8 CT 1.700 F-355X 26.8 CT 1.700 F-122X 28.0 CT 0.175 F-124X 28.0 CT 0.800 C F-184X 28.0 CT 1.000 F-3185U 28 ...

Related keywords