Description
Controller, Phase; 2.9; 120 VAC; 25 A; 0 to 118 VAC; 50/60 Hz; Single Phase
Manufacturer
Payne Controls Company
Type
Variable Voltager
Datasheet

Specifications of 18TB-1-25

Brand/series
18TB Series
Capacity
2.9 kVA
Current, Output
25 A
Dimensions
4"W×6.3"H×3.5"D
Frequency, Operating
50⁄60 Hz
Mounting Type
Panel
Power, Rating
2900 W
Primary Type
Controller
Voltage, Input
120 VAC
Voltage, Output
0 to 118 VAC
Voltage, Supply
120 VAC
Page 36
P A YN E
ENGINEERING
DESCRIPTION: Single Phase, Variable Voltage Control
APPLICATION: Constant Resistance Loads
NOTES:
1.
2.
3.
4.
Fig. 1 Model 18TBP
18TBP-1-5
18TBP-1-10
18TBP-1-15
18TBP-2-5
18TBP-2-10
18TBP-2-15
18TB-1-15
18TB-1-25
18TB-2-15
18TB-2-25
18TP-1-5
18TP-1-10
18TP-1-15
18TP-2-5
18TP-2-10
18TP-2-15
Number
Model
Model 18TBP controls designed for panel mounting.
(See Fig. 1)
Model 18TB controls designed for chassis mounting.
Includes control pot and 2 feet of control cable.
Model 18TP controls may be used as portable or
permanently mounted units. Includes three prong
plug, 6 ft. of cable, 3 prong receptacle, and
lighted On/Off switch. (See Fig. 3)
All 18TBP/TB/TP controls have factory tested and
approved 2-millisecond fuses installed.
SINGLE PHASE, 240 VAC INPUT, 0-235 VAC OUTPUT, 50/60Hz (ALSO FOR 208/220/230 VAC INPUT)
SINGLE PHASE, 240 VAC INPUT, 0-235 VAC OUTPUT, 50/60Hz (ALSO FOR 208/220/230 VAC INPUT)
SINGLE PHASE 240 VAC INPUT, 0-235 VAC OUTPUT, 50/60Hz (ALSO FOR 208/220/230 VAC INPUT)
Amps
Fuse
10
15
10
15
15
25
15
25
10
15
10
15
5
5
5
5
Fig. 2 Model 18TB
SINGLE PHASE, 120 VAC INPUT, 0-118 VAC OUTPUT, 50/60Hz
SINGLE PHASE, 120 VAC INPUT, 0-118 VAC OUTPUT, 50/60Hz
SINGLE PHASE, 120 VAC INPUT, 0-118 VAC OUPUT, 50/60Hz
MODEL 18TBP
MODEL 18TP
MODEL 18TB
Watts @ Max
Rated Volts
1200
1800
1200
2400
3600
1800
2900
3600
5900
1200
1800
1200
2400
3600
600
600
5.
6.
7.
Fig. 3 Model 18TP
For higher voltage or amperage ratings, or for control
features not shown here, refer to Model 18D, page 14.
For recommended spare fuses, see FUSE CHART,
page 39. Use of any other fuse voids all warranties.
Enclosures supplied by others must be properly
ventilated. See VENT SCHEDULE, page 43.
Model
18TBP/TB/TP
Open Chassis Dimensions
2.5
2.5
2.5
2.5
2.5
2.5
6.3
6.3
2.5
2.5
2.5
2.5
Height Width Depth
4
4
4
4
Inches
5.12
5.12
2.5
2.5
2.5
2.5
2.5
2.5
4.7
4.7
4.7
4.7
4
4
4
4
2.74
2.74
2.5
2.5
3.5
3.5
2.5
2.5
2.5
2.5
2
2
2
2
2
2

Related parts for 18TB-1-25

Related keywords