33521A Agilent Technologies Test Equipment, 33521A Datasheet - Page 5

no-image

33521A

Manufacturer Part Number
33521A
Description
Arbitrary Waveform Generator, 30 MHz
Manufacturer
Agilent Technologies Test Equipment
Datasheet

Specifications of 33521A

Application Type
Electronic controls, baseband wireless communications, Linear amplifiers, DC brushless motors, switching power supplies, Medical devices, digital audio, Clock signals, modulation source
Bandwidth
1 mHz to 30 MHz, variable
Channel Type
Dual Channel Mode
Duty Cycle
0.01% to 99.99%
Frequency Range
1 μHz to 30 MHz, 1 μHz resolution
Memory Type
1 MSa waveform memory standard
Sampling Rate
16-bit, 16 ns minimum, 100-ps resolution
Time, Rise
and fall: Square: 8.4 ns, fixed Pulse: 8.4 ns to 1 μs, independently variable, 100-ps or 3-digit
Arbitrary waveform characteristics, continued
Output characteristics
Frequency accuracy
Waveform sequencing
Operation
Segment length
Sequence length
Segment repeat count
Isolation
Outputs
Signal output
Output impedance (nom)
On, off, inverted
Voltage limit
Overload protection
Built-in arbitrary
Amplitude
Range
Resolution
Units
Accuracy
DC offset
Range
Resolution
Units
Accuracy
Standard freqeuncy reference (spec)
1 year, 23°C ± 5°C
1 year, 0°C to 55°C
High-stability frequency reference (spec): Option 010
1 year, 0°C to 55°C
5
1, 2
1, 2
(spec)
(spec)
Individual arbitrary waveforms (segments) can be combined into user-defined
lists (sequences) to form longer, more complex waveforms. Each sequence step
specifies whether to repeat the associated segment a certain number of times,
to repeat it indefinitely, to repeat it until a Trigger event occurs, or to stop and
wait for a Trigger event. Additionally, the behavior of the Sync output can be
specified in each step.
To improve throughput, up to 32 sequences totalling up to 1,024 segments can be pre-
loaded into volatile memory.
8 Sa to 1 MSa (16 MSa with Option 002) in increments of 1 sample
1 to 512 steps
1 to 1x10
Connector shells for channel output(s), Sync, and Mod In are connected
together but isolated from the instrument’s chassis. Maximum
allowable voltage on isolated connector shells is ±42 Vpk
50 Ω
User-selectable for each channel
User-definable V
Output turns off automatically when an overload is applied
Instrument will tolerate a short-circuit to ground indefinitely
Cardiac, exponential fall, exponential rise, Gaussian pulse,
Haversine, Lorentz, D-Lorentz, negative ramp, sinc
1 mVpp to 10 Vpp into 50 Ω
2 mVpp to 20 Vpp into open circuit
4 digits
Vpp, Vrms, or dBm, selectable
±1% of setting ±1 mVpp at 1 kHz
±(5 VDC - Peak AC) into 50 Ω
±(10 VDC - Peak AC) into open circuit
4 digits
VDC
±1% of Offset setting ±0.25% of Amplitude setting ±2mV
±1 ppm of setting ± 15 pHz
±2 ppm of setting ± 15 pHz
±0.1 ppm of setting ± 15 pHz
6
, or infinite
MAX
and V
5
MIN
limits