TL-W1R5MC1 Omron Automation, TL-W1R5MC1 Datasheet
![no-image](/images/no-image-200.jpg)
TL-W1R5MC1
Specifications of TL-W1R5MC1
Available stocks
Related parts for TL-W1R5MC1
TL-W1R5MC1 Summary of contents
Page 1
... Unshielded Shielded 5 mm *1. Models with a different frequency are also available to prevent mutual interference. The model numbers are TL-W@M@@5 (e.g., TL-W5MD15). *2. Models with robotics cables are also available. The model numbers are TL-W@MC1-R (e.g., TL-W1R5MC1-R). Model Operation mode NO NC TL-W5MD1 *1 TL-W5MD2 *1 ...
Page 2
... Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. TL-W5MD Refer to the timing charts under I/O Circuit Diagrams on page 6 for details. min. (at 500 VDC) between current-carrying parts and case 2 3 times each and Z directions TL-W 2 ...
Page 3
... DC 3-Wire Models Model TL-W1R5MC1 Item Sensing distance 1.5 mm 10% Set distance 0 to 1.2 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.) Standard sensing Iron object Response 1 kHz min. frequency ...
Page 4
... I/O Circuit Diagrams DC 2-Wire Models Operation mode Model Non-sensing area Sensing object (%) NO TL-W5MD1 Sensing object (%) NC TL-W5MD2 DC 3-Wire Models Operation mode Model TL-W1R5MC1 NO TL-W3MC1 TL-W5MC1 TL-W3MC2 NC TL-W5MC2 TL-W5E1 NO TL-W20ME1 TL-W5E2 NC TL-W20ME2 NO TL-W5F1 NC TL-W5F2 Timing chart Set position Unstable Stable sensing sensing area ...
Page 5
... Dimensions TL-W1R5MC1 8 Sensing surface Mounting Bracket (Attachment) 22.4 16 5.5 (See note.) 3.2 dia. 7.8 1 3.2 R1.6 R1.6 3 2.9-dia. vinyl-insulated round cable with 0.2 3 conductors (Conductor cross section: 7 0.14 mm Standard length Note: Mounting hole dimension: 17 ±0.2. Material: Stainless steel (SUS304) TL-W5MC@ TL-W5MD@ 30 ...