FREEDOM 10/OCTAL ARTISAN CONTROLS, FREEDOM 10/OCTAL Datasheet - Page 2

no-image

FREEDOM 10/OCTAL

Manufacturer Part Number
FREEDOM 10/OCTAL
Description
Relay; SSR; Timing; On Delay; DPDT; Cur-Rtg 5A; Ctrl-V 24-240AC/DC; Vol-Rtg 250AC; 8 Pin
Manufacturer
ARTISAN CONTROLS
Datasheet

Specifications of FREEDOM 10/OCTAL

Brand/series
Freeedom10®
Contact Configuration
DPDT
Contact Form
DPDT
Current, Rating
5 A
Dielectric Strength
1000 V (RMS) Between Open Contact Sets, 1500 V (RMS) Between Contacts and Operating Voltage Terminals
Function
Timing
Material, Body
Plastic Case
Material, Contact
Gold-Clad Silver Nickel
Number Of Pins
8
Power, Rating
1250 VA
Relay Type
Solid State
Standards
UL
Temperature, Operating, Minimum
-20
Timer Type
On Delay
Timing Range
1 to 100 sec., 0 to 15 min.
Voltage, Control
240 VAC⁄VDC
Voltage, Rating
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repeatability Of Timing Period:
Output Rating Resistive Load:
Freedom 10 - Octal
Freedom 10 - Spade
Data Sheet Revision Date:
Adjustable Timing Range:
Max. Switching Voltage:
Max. Switching Current:
Operating Temperature:
Max. Switching Power:
Min. Switching Power:
Agency Recognitions:
Transient Protection:
Part Number
Timing Adjustment:
Operating Voltage:
Operating Current:
Timing Tolerance:
Solid State Timers and Controllers
Timing Variation:
Contact Material:
Timing Diagram:
Expected Life:
Recycle Time:
Terminations:
Timing Mode:
Dielectric:
Output:
24V - 240V AC or DC
24V - 240V AC or DC
24V to 240V AC 50/60 Hz or 24V to 240V DC. No need to observe
polarity of operating voltage when wiring. Operating voltage must be
applied with less than 5 milliseconds rise time at any operating voltage.
25 milliamperes at any operating voltage AC or DC.
Delay-On-Make.
1 - 100 seconds, and 0 - 15 minutes.
Two (2) integral potentiometers.
temperature based on potentiometer setting.
If recycled during a timing period (contacts de-energized), the operating
voltage must be removed for a minimum of 200 milliseconds, if after a
timing cycle (contacts energized), the operating voltage must be
removed for a minimum of 50 milliseconds.
DPDT relay contacts.
Gold-clad silver nickel.
5A 125, 250V AC 1/20 HP 125, 250V AC, 5A 30V DC.
1,250 VA
250V AC
5A
100 microamperes @ 1V DC.
100,000 at 5A 125V AC, 3A 250V AC, 50,000 at 5A 30V DC.
1,000V rms between open contact sets, 1,500V rms between contacts
and operating voltage terminals.
Solid state timing circuits protected by silicon transient suppressors
responding to transients within 1 x 10
dissipation of 1500 watts, with transient surge currents to 200 amperes
for durations up to 1/120 second at 25˚ C. Maximum transient voltage
protection is 6000 volts as delivered through a source resistance of 30
ohms with a maximum duration of 8.3ms.
-20˚C to +55˚C
11 terminal Spade or 8 pin octal plug in.
UL File #E47858 (Component Appliance Controls #ATNZ2),
May 16, 1995
10% of scale set point.
15% worst case at any combination of operating voltage and
1% at stabilized operating voltage temperature.
Operating Voltage
The RECYCLE TIME To Assure Another Output Cycle
Operating Voltage Must Be Removed For At Least
Operating Voltage
Output Contacts
ON
Energized
Output Contacts Energize
After Preset Timing Period
Recycle
Time
1 Sec. through 15 min.
1 Sec. through 15 min.
Adjustable Timing Range
-12
seconds to a peak pulse power