GV2P16 TELEMECANIQUE, GV2P16 Datasheet

no-image

GV2P16

Manufacturer Part Number
GV2P16
Description
Starter, Manual/Protector, GV2 Series, Rotary Handle, 0.75HP, 600VAC, Trip 9-14A
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of GV2P16

Function
Motor Starter
Primary Type
Motor Starter
Lead Free Status / Rohs Status
RoHS Compliant part
6
GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors
Standard Features
Table 1:
Protection
Mounting
Connection
Marking
Trip test
Signaling on the front face
Padlocking
Tamper-proof
current dial
Accessories
Selection
Manual control
device
Mechanical
flag indicator
Front-mounting
accessories
Side-mounting
accessories
(snap onto the
starters without
the use of a tool)
Other
accessories
6/2010
Standard Features
Thermal-magnetic (overload relays are bimetallic—Class 10)
Screw terminals using cross-head, captive screws. Cross-head
screws used for connections on GV2 starters and their add-on
blocks.
Using the marker holder supplied with each unit.
Using a fine-blade screwdriver on the front face of the product.
On or Off state
Padlocks in the Off position using the system incorporated into the manual control device.
(Padlocks are supplied by the customer.)
Instantaneous contact blocks—either N.C., N.O., N.O. + N.O., or N.O. + N.C.—which do not increase
the width of the product.
On the left side, contact blocks which provide the following:
On the right side:
Page 38
0.1 to 32 A
Up to 20 hp @ 460 V
10 kA SCCR @ 480 V
Push Button Operator
Clip-on mounting on 35 mm
DIN rail. Unclips without the
use of a tool.
Panel mounts using a metal
adapter plate.
N.O. + N.O. or N.O. + N.C. instantaneous contacts
N.O. or N.C. trip signaling contact incorporating a mechanical flag indicator and an N.O. or N.C.
instantaneous contact
C/O magnetic trip signaling contact, associated with a mechanical flag indicator, used for reset.
Shunt trip or undervoltage trip
Combination block for use
with TeSys
Bus bars and connectors
GV2ME
®
contactor
Trips on short circuit
The thermal-current setting dial is
covered by a transparent cover,
which can be sealed.
Page 38
0.1 to 30 A
Up to 15 hp @ 460 V
50 kA SCCR @ 480 V
Rotary Handle Operator
Visible Trip Indication
Clip-on mounting on 35 mm
DIN rail. Unclips without the
use of a tool.
Panel mounts directly.
On or Off state
Trip on overload,
short circuit, undervoltage,
or shunt trip.
Visible isolation block,
mounting on the incoming
terminals of the device
Door interlock mechanism
GV2P
Uses an Allen wrench.
Trips on short circuit
Page 38
9 to 65 A
Up to 40 hp @ 460 V
GV3P13–GV3P32 rated
100 kA SCCR @ 480 V
GV3P40–GV3P65 rated
65 kA SCCR @ 480 V
Rotary Handle
Clip-on mounting on 35 mm
DIN rail. Unclips without the
use of a tool.
Panel mounts directly.
On or Off state
Trip on overload,
short circuit, undervoltage,
or shunt trip.
GV3P
© 2001–2010 Schneider Electric
Solid-state overload relay—
magnetic short circuit (Class 10)
Panel mounts directly
Clip-on connectors
(sold separately)
On or Off state
short circuit
Padlockable when used with a
door-mounted rotary handle or
with a separate locking device
Front accessible,
internally mounted:
Rotary Handles
Page 39
Trip on overload or
25 to 220 A
Up to 150 hp @ 460 V
25 kA SCCR @ 480 V
Toggle Operator
Auxiliary contacts
Trip indication contacts
Shunt trip
Undervoltage trip
GV7RE/GV7RS
All Rights Reserved

Related parts for GV2P16

GV2P16 Summary of contents

Page 1

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Table 1: Standard Features GV2ME 0 460 SCCR @ 480 V Push Button Operator Protection Thermal-magnetic (overload ...

Page 2

... GV2P05 0.63–1 100 GV2P06 1–1.6 100 GV2P07 1.6–2.5 100 GV2P08 2.5–4 100 GV2P10 4–6.3 100 GV2P14 6–10 100 GV2P16 9–14 10 GV2P20 13–18 10 GV2P21 17–23 10 GV2P22 20–25 10 SCCR (kA) Overload Trip Range (A) 480Y/277 V 600Y/347 V 9–13 100 25 12– ...

Page 3

... Cable, AWG Self-Protected 75 °C, Cu Starter 600 V 10 GV2P01 10 GV2P02 10 GV2P03 10 GV2P04 10 GV2P05 10 GV2P06 10 GV2P07 10 GV2P08 10 GV2P10 7.5 10 GV2P14 10 8 GV2P16 15 8 GV2P20 20 6 GV2P21 20 6 GV2P22 Associated Manual Overload Cable, Self-Protected Trip Range AWG Starter (A) 75 °C, Cu 600 GV3P13 9– GV3P18 12– ...

Page 4

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors UL 508 Group Motor Installations Table 6: TeSys GV2ME Horsepower and SCCR Ratings In association with LC1D contactors, suitable for group installation when protected by fuses or an inverse-time circuit ...

Page 5

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Specifications and Operating Curves Specifications and Operating Curves GV2 Specifications Table 7: Environment Type GV2ME IEC 60947-1, 60947-2, 60947-4-1, EN 60204, BS 4752, BS 4941, UL 508, CSA C22.2 No. ...

Page 6

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Table 8: Technical Characteristics Type Utilization category Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated operational frequency Rated impulse withstand voltage (U imp) Total power dissipated per pole (W) ...

Page 7

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Specifications and Operating Curves Table 10: GV Auxiliary and Fault Signaling Contact Specifications Type Instantaneous Auxiliary Contacts GVAN, GVAD Rated insulation voltage (Ui) (associated insulation coordination) 690 V Conforming to ...

Page 8

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Table 11: Type Rated insulation voltage (Ui) (associated insulation coordination) Conforming to IEC 60947-1 Conforming to CSA C22.2 No. 14 and UL 508 Conventional rated thermal current (Ith) Conforming to ...

Page 9

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Specifications and Operating Curves Table 12: 3-Pole Busbars GV2G• Rated insulation voltage (Ui) Conventional rated thermal current (Ith) Permissible peak current (I peak) Permissible thermal limit (I Degree of protection ...

Page 10

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors GV2 Operating Curves Table 13: Average operating time at 68 °F (20 ° function of multiples of the setting current Time (s) 10,000 1000 100 10 1 0.1 ...

Page 11

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Specifications and Operating Curves Table 14: For GV2M and GV2P 3Ø, 400/415 V Dynamic stress 1 peak = f (prospective Isc 435 V Maximum peak current ...

Page 12

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Table 15: Thermal limit Sum (prospective Isc 435 V 2 Sum (kA s) 100 10 ...

Page 13

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Specifications and Operating Curves Table 16: Thermal limit Sum (prospective Isc 435 V 2 Sum ...

Page 14

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Table 17: GV2ME Breaking Capacity for European Applications Type [1] Rating 230/240 V 400/415 V Breaking capacity 440 V conforming to IEC 60947-2 500 V 690 V 230/240 V 400/415 ...

Page 15

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Specifications and Operating Curves Table 19: GV2P•• Breaking Capacity for European Applications When Used with Current Limiter GV1L3 Type [1] Rating 230/240 V 400/415 V Breaking capacity conforming to IEC ...

Related keywords