E3Z-LS81 Omron Automation, E3Z-LS81 Datasheet - Page 6

no-image

E3Z-LS81

Manufacturer Part Number
E3Z-LS81
Description
SENSOR, DISTANCE SETTABLE, PNP, PRE-WIRED
Manufacturer
Omron Automation
Type
Thru Beamr
Datasheet

Specifications of E3Z-LS81

Body Style
Rectangular
Current, Switching
100 mA
Function
Proximity
Ip Rating
IP67
Mounting Type
Bracket
Output
PNP
Primary Type
Photoelectric
Range, Measurement
200 mm
Sensing Mode
Retro-Reflective
Technology
Photoelectric
Termination
Pre-Wired
Voltage, Supply
24 VDC
Voltage, Switching
26.4 VDC
Voltage Range
12-24 VDC
Load Rating
100 mA @ 26.4 VDC Max.
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3Z-LS81
Manufacturer:
OMRON
Quantity:
1 000
Part Number:
E3Z-LS81
Manufacturer:
OMRON
Quantity:
374
I/O Circuit Diagrams
NPN Output
E3Z-LS61
E3Z-LS66
E3Z-LS63
E3Z-LS68
E3Z-LS61
E3Z-LS66
Model
Distance threshold
NEAR
(set distance)
Operation
Light-ON
Dark-ON
Light-ON
Dark-ON
mode
FAR
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
threshold (not settable)
Incident light level
Only for FGS mode
(Between brown and black leads)
(Between brown and black leads)
(Between brown and black leads)
(Between brown and black leads)
Timing charts
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
VERY FAR
NEAR
NEAR
NEAR
NEAR
FAR VERY FAR
FAR VERY FAR
FAR
FAR
(DARK ON)
(DARK ON)
Operation
selector
(LIGHT
(LIGHT
D side
D side
L side
L side
Note: The VERY FAR region is supported only for FGS.
ON)
ON)
The incident light level threshold is fixed and cannot be set.
BGS:
Either leave
the pink
wire (2)
open or
connect it to
the blue
wire (3).
FGS:
Connect
the pink
wire (2) to
the brown
wire (1).
BGS/FGS
selection
method
Operation
indicator
(orange)
Connector Pin
Arrangement
1
2
Stability
indicator
(green)
4
3
Photo-
electric
Sensor
Main
Circuit
Output circuit
(Control output)
Z
D
1
2
4
3
e-CON Connector
Brown
Pink
Black
Blue
Pin Arrangement
1
2
3
4
E3Z-LS
FGS
BGS
100 mA
max.
12 to 24 VDC
Load (relay)
0 V
6

Related parts for E3Z-LS81