S8VS-24024A Omron Automation, S8VS-24024A Datasheet - Page 4

no-image

S8VS-24024A

Manufacturer Part Number
S8VS-24024A
Description
Power Supply; 100 to 240 VAC; 3.8 A (Max.) @ 100 V/2.0 A (Max.) @ 200 V; 100 mm
Manufacturer
Omron Automation
Datasheet

Specifications of S8VS-24024A

Brand/series
S8VS Series
Configuration
Enclosed
Current, Inrush
25 A (Max.) @ 100 V, 50 A (Max.) @ 200 V
Current, Rating
3.8 A (Max.) @ 100 V⁄2.0 A (Max.) @ 200 V
Frequency
50⁄60 Hz
Height
115 mm
Mounting Type
DIN Rail
Number Of Outputs
1
Operation
Switching
Output
24 VDC @ 10 A
Power, Output
240 W
Primary Type
AC-DC
Voltage, Input
100 to 240 VAC
Voltage, Output
24 VDC
Voltage, Rating
100 to 240 VAC
Width
100 mm
Lead Free Status / Rohs Status
RoHS Compliant part
Note: Refer to page 5 for notes 1 to 11.
Item
Efficiency (typical)
Input
Output
Additional
functions
Other
Voltage *1
Frequency *1
Current
Power factor
Harmonic current emissions
Leakage current
Inrush current *2
Voltage adjustment range *3
Ripple
Input variation influence
Load variation influence
(rated input voltage)
Temperature variation influence
Startup time *2
Hold time *2
Overload protection *2
Overvoltage protection *2, *4
Output voltage indication *5
Output current indication *5
Peak-hold current indication *5
Maintenance forecast monitor indication *5 No
Maintenance forecast monitor output
Total run time monitor indication *5
Total run time monitor output *5
Undervoltage alarm indication *5
Undervoltage alarm output terminals
Parallel operation
Series operation
Operating ambient temperature
Storage temperature
Operating ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
EMI
EMS
Approved standards
SEMI
Weight
100-V input
200-V input
100-V input
200-V input
100-V input
200-V input
Conducted
Emissions
Radiated
Emissions
Power ratings
Type
80% min.
100 to 240 VAC (85 to 264 VAC)
50/60 Hz (47 to 63 Hz)
3.8 A max.
2.0 A max.
0.95 min.
Conforms to EN61000-3-2
0.5 mA max.
1.0 mA max.
25 A max. (for a cold start at 25°C)
50 A max. (for a cold start at 25°C)
Models with indication monitor: ±10% (with V.ADJ)
Standard models: −10% to 15% (with V.ADJ)
2.0% (p-p) max. (at rated input/output voltage)
0.5% max. (at 85- to 264-VAC input, 100% load)
1.5% max. (with rated input, 0 to 100% load)
0.05%/°C max.
1,000 ms max. (at rated input/output voltage)
20 ms min. (at rated input/output voltage)
105% to 160% of rated load current, voltage drop, automatic reset
Yes
No
No
No
No
No
No
No
No
No
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in Engineering Data (60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models). (with no icing or
condensation)
−25 to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard 240-W and 480-W
models: 30 mA, detection current for 240-W models with indication monitor: 20 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions: 240 W
10 to 150 Hz, 0.35-mm single amplitude (3 G max.) for 80 min each in X, Y, and Z directions: 480 W
150 m/s
Yes (color: green)
Models with indication monitor: Conforms to EN61204-3
EN55011 Class A and based on FCC Class A, Conforms to
EN61204-3 EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1
Class B and based on FCC Class A
Models with indication monitor: Conforms to EN61204-3
EN55011 Class A, Conforms to EN61204-3 EN55011 Class B
*11
Standard models: Conforms to EN61204-3 EN55011 Group 1
Class B
Conforms to EN61204-3 high severity levels
UL: UL508 (Listing), UL60950-1
cUL for 240-W models with indication monitor: CSA C22.2 No.14,
cUL for 240-W standard models and 480-W models: CSA C22.2 No.107.1,
cUR: CSA No. 60950-1,
EN/VDE: EN50178 (=VDE0160),
EN60950-1 (SELV) (=VDE0805 Teil 1)
According to VDE0106/P100, IP20 (except terminal block)
KOSHA S Mark *10
F47-0200 (200-VAC input)
1,150 g max.
Standard
2
, 3 times each in ±X, ±Y, and ±Z directions
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
Yes (transistor
output), 30 VDC
max., 50 mA max. *9
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA
max. *9
forecast monitor
Maintenance
240 W
No
No
Yes (selectable)
Yes (transistor
output), 30 VDC
max., 50 mA max. *9
Total run time
monitor
83% min.
7.4 A max.
3.9 A max.
−10% to 15% (with V.ADJ)
No
No
No
No
No
No
No
Conforms to EN61204-3 EN55011 Class A and based on FCC
Class A
Conforms to EN61204-3 EN55011 Class B *11
Conforms to EN61204-3 EN55011 Class A
Conforms to EN61204-3 EN55011 Class B *11
1,700 g max.
Standard
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
Yes (transistor
output), 30 VDC
max., 50 mA max.
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA
max. *9
forecast monitor
Maintenance
480 W
No
No
Yes (selectable)
Yes (transistor
output), 30 VDC
max., 50 mA max. *9
Total run time
monitor
S8VS
7