16-1-H-P1 Time Mark Corporation, 16-1-H-P1 Datasheet

no-image

16-1-H-P1

Manufacturer Part Number
16-1-H-P1
Description
VOLTAGE MONITOR, 30-380V, 8-PIN OCTAL
Manufacturer
Time Mark Corporation
Datasheet
DESCRIPTION
The Model 16-1-X-X protects equipment from Over,
Under, Over/Under voltage or rapid cycling conditions
that can damage valuable equipment. Trip and restart
delays are adjustable, or can be disabled. Input voltage
ranges are 12-30 Vac/Vdc or 30-277 Vac/Vdc. The 8-pin
plug-in has 2 SPDT relays, while the surface mount case
has 1 SPDT relay. See Ordering Information for details.
8-pin plug-in versions require an 8-pin socket, such as
Time Mark's Model 51X120.
A proprietary microcontroller-based sensing circuit de-
energizes the relay(s) after the trip delay
detection of harmful voltage conditions. The relay(s) will
energize after power line conditions return to an
acceptable level and the restart delay time has expired
enabled)
tripping while restart delays can be used to stagger the
startup of equipment or protect compressors. Time
Mark’s proprietary microcontroller-based design offers
maximum flexibility with an easy to use interface.
Model
ORDERING INFORMATION:
example: 16-1-H-S
accepts an AC/DC input voltage between 30 - 277 volts in a surface mount enclosure
with 5 spade connections and a SPDT relay
Telephone: Main (918) 438-1220
E-mail:
Internet:
16 -
Over / Under Voltage Monitor
16 1=
Monitors AC or DC single phase voltages
for over, under or over/under voltage
Adjustable Trip & Restart, can be disabled
5 LED’s: Trip, Normal & Delay status
Universal range: 12–30 or 30–277 Vac/Vdc
8 pin plug-in case
Surface mount case - 1 SPDT relay
with Trip and Restart Delay
2=Over/Under Voltage %
3=Voltage Pickup/Dropout
Over/Under Voltage
. Trip delays can be added to avoid nuisance
see model 16-2 datasheet
see model 16-3 datasheet
MODEL 16-1-X-X
Sales (800) 862-2875
Fax:
sales@time-mark.com
http://www.time-mark.com
Series
1
orders an Over/Under single phase voltage monitor that
(918) 437-7584
L=
12 - 30 Vac or Vdc
H=
30 - 277 Vac or Vdc
-
Input Voltage
- 2 SPDT relays
X
P=8-pin plug-in case
S=Surface mount case
with 5 spade connections
-
(if enabled)
Two (2) SPDT Relays
One (1) SPDT Relay
Enclosure
X
upon
(if
SPECIFICATIONS
DIMENSIONS - 8 Pin Case
MODEL
Input Voltage-L version
Frequency
Supply Current
Initial Startup
Response time
Restart Delay
Trip Delay
Transient Protection
Repeat Accuracy
Reset Type
Dead Band
Output Contacts
Expected Relay life
Enclosure Material
Operating Temperature
Humidity Tolerance
Mounting
Weight
-H version
8-pin:
Surface mount: SPDT
Mechanical:
Electrical:
8-pin case
8 pin: 4.4 oz
Surface mount w/ 5 blade connectors
8 pin: 65mA
48mS (<100 mS w/ relay flight time)
30 - 277 Vac or Vdc Single Phase
12 - 30 Vac or Vdc Single Phase
8 pin socket
0 – 97% w/o condensation
© 2007
TIME MARK is a division of
0 deg. F to +130 deg. F
Tu l s a , O k l a h o m a 7 4 1 1 6
1 1 4 4 0 E a s t P i n e S t r e e t
10,000,000
100,000 min @ rated load
DC, 50 / 60Hz
1500W / 1mS
< 3 seconds
SPDT x 2 10A @ 240 Vac
ABS plastic
0 - 300 sec
0 - 30 sec
Automatic
16-1-X-X
+ /- 0.1%
(Time Mark # 51X120)
TIME MARK CORPORATION
Surface mount: 32mA
Surface mount: 4.0 oz
2%
Surface mount case
10A @ 240 Vac
06/07

Related parts for 16-1-H-P1

16-1-H-P1 Summary of contents

Page 1

... SPDT relays Surface mount case - 1 SPDT relay DESCRIPTION The Model 16-1-X-X protects equipment from Over, Under, Over/Under voltage or rapid cycling conditions that can damage valuable equipment. Trip and restart delays are adjustable, or can be disabled. Input voltage ranges are 12-30 Vac/Vdc or 30-277 Vac/Vdc. The 8-pin plug-in has 2 SPDT relays, while the surface mount case has 1 SPDT relay ...

Page 2

... READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE. KEEP THIS DATA SHEET FOR FUTURE REFERENCE. POTENTIALLY HAZARDOUS VOLTAGES ARE PRESENT AT THE TERMINALS OF THE MODEL 16. ALL ELECTRICAL POWER SHOULD BE REMOVED WHEN CONNECTING OR DISCONNECTING WIRING. THIS DEVICE SHOULD BE INSTALLED AND SERVICED BY QUALIFIED PERSONNEL. ...

Page 3

... Over/Under Voltage Monitor with Trip and Restart Delay TYPICAL APPLICATION - Surface mount Shows No Power Applied L1 L2 CONTROL VOLTAGE LED STATUS NONE RED RESTART DELAY - Yellow Blinking The Model restart delay. GREEN O/L’s MOTOR M NO STOP C START NC REMARKS Measure input voltage and verify the voltage falls within the range of the unit ...

Related keywords