WMZT2C15 Eaton / Control Automation, WMZT2C15 Datasheet

no-image

WMZT2C15

Manufacturer Part Number
WMZT2C15
Description
CIRCUIT BREAKER, TYPE WMZT, 10KA, 2 POLE, 15A, C CURVE
Manufacturer
Eaton / Control Automation
Type
Thermal/Magneticr
Datasheet

Specifications of WMZT2C15

Actuator Type
Toggle
Brand/series
WMZT
Characteristic
C
Current, Rating
15 A
Dimensions
105 × 17.7 (per pole) mm
Mounting Type
DIN Rail
Number Of Poles
2
Special Features
Trip Indictator
Termination
Scrrew
Voltage, Rating
48/240 VDC/VAC
Lead Free Status / Rohs Status
RoHS Compliant part
UL 489 DIN Rail
Miniature Circuit Breakers
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers
2
4
6
1

Related parts for WMZT2C15

WMZT2C15 Summary of contents

Page 1

... UL 489 DIN Rail Miniature Circuit Breakers Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers ...

Page 2

... Relays • UPS • Power conditioners • 2 EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers Features Complete range of UL 489 listed DIN rail mounted miniature • circuit breakers ampere current rating Complete family rated for 10 kAIC @ 277/480 Vac • Current limiting design provides fast short circuit interruption • ...

Page 3

... Products meet the requirements of the Canadian Electrical Code (CEC). Tripping characteristics Eaton WMZT branch circuit breakers are available with “C” and “D” tripping characteristics. C-curve devices are suitable for application where medium levels of inrush current are expected. Applications include small trans- formers, lighting, pilot devices, control circuits, and coils ...

Page 4

... WMZT2C02 WMZT1C03 WMZT2C03 3 4 WMZT1C04 WMZT2C00 5 WMZT1C05 WMZT2C05 6 WMZT1C06 WMZT2C06 7 WMZT1C07 WMZT2C07 8 WMZT1C08 WMZT2C08 10 WMZT1C10 WMZT2C10 13 WMZT1C13 WMZT2C13 15 WMZT1C15 WMZT2C15 16 WMZT1C16 WMZT2C16 20 WMZT1C20 WMZT2C20 25 WMZT1C25 WMZT2C25 30 WMZT1C30 WMZT2C30 32 WMZT1C32 WMZT2C32 40 WMZT1C40 WMZT2C40 D Curve (10 – 20X I Current Rating) n 0.5 WMZT1DX0 WMZT2DX0 1 WMZT1D01 WMZT2D01 1 ...

Page 5

... WMZT2C03T 3 4 WMZT1C04T WMZT2C04T 5 WMZT1C05T WMZT2C05T 6 WMZT1C06T WMZT2C06T 7 WMZT1C07T WMZT2C07T 8 WMZT1C08T WMZT2C08T 10 WMZT1C10T WMZT2C10T 13 WMZT1C13T WMZT2C13T 15 WMZT1C15T WMZT2C15T 16 WMZT1C16T WMZT2C16T 20 WMZT1C20T WMZT2C20T 25 WMZT1C25T WMZT2C25T 30 WMZT1C30T WMZT2C30T 32 WMZT1C32T WMZT2C32T 40 WMZT1C40T WMZT2C40T D Curve with Ring-Tongue Terminals (10 – 20X I 0.5 WMZT1DX0T WMZT2DX0T 1 WMZT1D01T WMZT2D01T 1 ...

Page 6

... Bus Bar Shroud Extension Terminal — – 14 AWG) Bus Connector — Conductors Contact sales office for availability. 6 EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers Tripping Signal Switch WMZSAUXTRIP, WMZTAUX Design according to IEC/EN 60947-5-1, IEC/EN 62019 Catalog Number • Field installable WMZSAUXTRIP • ...

Page 7

... Onto Switching Dev. IP40 Finger and Hand Touch Safe According to BGV A3, ÖVE-EN 6 Lift Terminals 20 – 14 AWG M3 (Pozidrive Z0) 7 lb-in EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers WMZT Circuit Breakers ACCESSORIES WMZTAUX 1NO + 1NC 250V 50/ 250 Vac 2A / 250 Vac ...

Page 8

... Finger and Hand Touch Safe According to BGV A3, ÖVE-EN 6 Terminals Open Mouthed / Lift Terminal Capacity 1 and 18 – 10 AWG 2 Wires 8 EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers Bus Bar Block UL489 (Pin) Tested according to UL 489 • Do not cut • Extension terminal 35 mm • ...

Page 9

... AWG UL 486B # 8 – 12 AWG UL 486E # 6 – 1 AWG UL 489 DIN Rail Miniature Circuit Breakers Lockout Attachment WMZPLK IEC/EN60947-2 2.5 – Tightening Torque of Terminal Screws ≥ 2.3 Nm ≥ 2 EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers WMZT Circuit Breakers ACCESSORIES WMZT3PSHROUD WMZT35EXT 9 ...

Page 10

... Terminal Fastening Torque AWG 18-21: 21 lb-in AWG 10-8: 25 lb-in AWG 6: 36 lb-in Mounting Independent of Position Calibration temperature UL 489, CSA C22.2 No.5 40°C IEC 60947-2 30°C 10 EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers Dimensions (mm) 3-pole 17.7 Power loss Characteristic [A] P [W] 0.5 1 ...

Page 11

... Let-Through Energy Characteristic C (0.5 – 20A), 277V Characteristic D (0.5 – 20A), 277V UL 489 DIN Rail Miniature Circuit Breakers Characteristic C (25 – 40A), 240V Characteristic D (25 – 40A), 240V EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers WMZT Circuit Breakers TECHNICAL DATA 11 ...

Page 12

... Influence of Ambient Temperature T on Load Carrying Capacity Ambient Temperature T [°C] Maximunm Load I at ambient temperature EATON CORPORATION UL 489 DIN Rail Miniature Circuit Breakers 25°C 30°C 0.5 0.5 0.5 1.1 1.1 1.0 1.6 1.6 1.6 2.2 2 ...

Related keywords