Function
Overload
Motor, Amp, Full Load
6.4-32
Relay Type
Solid State
Standard Version
Selectable Trip Class (5, 10, 20, 30) with Selectable Manual or Auto Reset
Broad 5
1 FLA range
Ul Listed And Csa Certified Components
Standalone, Starter-Mounted Devices
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
Stand Alone
6
Technical Data and Specifications
Table 11. Overload Relay Specifications
Protection
Trip Class
Reset
Indications
PCBA
Options
General
Description
Thermal
Phase Loss
Phase Imbalance
Inrush Current
Class 5, 10, 20, 30
M / M-O
A / A-O
Test Indicator
Trip Indicator
Power Sensing
Instant Reset by Power ON
Thermal memory
Cold and Hot Trip Curves
Power Consumption
Safety Cover
Remote Reset
C396 Electronic Overload
Stand-Alone Components
C396_2_
Standard
1.05 x FLA: Does not trip
1.25 x FLA: Overload trip
1 Phase = 0, Trip time = 3s (Hot Status)
Max - Min / Max > 40%,
Trip time = 3s (Hot Status)
> 8 x Max FLA, Trip time is 0.3s (Cold Status)
Manual / Manual + Stop
Auto / Auto + Stop
Auto Reset Time = 165s
Yellow
Yellow
3 phase
CPU reset by Power ON after 2 – 3s
< 3 min.
Power ON > 20 min. is Hot Status
< 300 mW
Covers FLA dial, DIP switches
24V DC, 24V AC, 120V AC, 240V AC
Selectable
For more information visit: www.eaton.com
Table 11. Overload Relay Specifications (Continued)
Climate Considerations
Voltages
FLA Range
Safety
Capacity
Load Terminal Capacity
Load Terminal Tightening Torque in Nm (lb-in)
General
Description
Ambient Temperature
(Operating)
Ambient Temperature
(Storage / Transportation)
Humidity
Altitude
(Operating)
Pollution (Operating —
External)
Mechanical Shock
Resistance
(IEC/EN 68-2-17)
Vibration (Lloyd’s Register of
Shipping, Vibration Test 2)
Temperature
Compensation
Control Voltage
Insulation Voltage (Ui) —
Main Circuit
Insulation Voltage (Ui) —
Control Circuit
Impulse Withstand Voltage
(Uimp) VAC
45 mm Frame: C396A_
65 mm Frame: C396B_
110 mm Frame: C396C_
Degree of Protection
Control Terminal Capacity
Control Terminal Tightening
Torque in Nm (lb-in)
45 mm Frame: C396A_
65 mm Frame: C396B_
110 mm Frame: C396C_
45 mm Frame: C396A_
65 mm Frame: C396B_
110 mm Frame: C396C_
Dimensions . . . . . . . . . . . . . . . . . . . . . . . Page 7 – 10
C396_2_
Standard
-25° to 65°C (-13° to 149°F) inside
enclosure
-40° to 80°C (-40° to 176°F)
UL991 (H3): 20 – 95% non-condensing
NEMA ICS1: 2000 meters max above
sea level
Pollution degree 3
15g
Continuous
12 – 690V AC, 50/60 Hz
1000V AC
690V AC
6000
0.1 – 45A
15 – 110A
30 – 150A
IP20 (Stand-Alone Version Only)
18 – 14 AWG
0.79 (7)
14 – 6 AWG
10 – 1 AWG
6 AWG – 250 mcm
3.2 (28)
9.0 (80)
22.6 (200)
6g