A22E-M-02B Sti (Scientific Technologies, Inc.), A22E-M-02B Datasheet - Page 8

no-image

A22E-M-02B

Manufacturer Part Number
A22E-M-02B
Description
SWITCH, EMERGENCY STOP, NON-LIGHTED, PUSH-LOCK, TURN RESET, W/ENCLOSURE, 2NC CONTA
Manufacturer
Sti (Scientific Technologies, Inc.)
Type
Pushbuttonr
Datasheet

Specifications of A22E-M-02B

Contact Form
2 NC
Function
E-Stop
Operation
Push-Lock
Lead Free Status / Rohs Status
RoHS Compliant part
* These Shrouds are for use with the equipment only that conforms to SEMI standards. Do not use them for any other applications (e.g. emergency
Specifications
Certified Standard Ratings
Ratings
Contacts (Standard Load)
10
current
E-stop Shroud for EMO,
Yellow
E-stop Shroud for EMO,
Yellow
E-stop Shroud for EMS,
White
E-stop Shroud for EMS,
White
E-stop Shroud, Yellow
• UL, cUL (File No.E41515)
• TÜV (EN60947-5-1) (Low Voltage Directive)
• CCC (GB14048.5)
Rated
carry
stop switches for machines or devices such as Machine tools, Printing presses, Industrial machinery, etc).
6A at 220 VAC, 10 A at 110 VAC
3 A at 220 VAC
3 A at 240 VAC, 1.5 A at 24 VDC
(A)
24 VAC
110 VAC 5
220 VAC 3
380 VAC 2
440 VAC 1
24 VDC
110 VDC
220 VDC
380 VDC
voltage
Rated
Item
(V)
10
---
(inductive
AC15
load)
10
10
6
3
2
---
(resistive
Appearance
Rated current (A)
AC12
load)
---
1.5
0.5
0.2
0.1
(inductive
DC13
load)
---
Legend plate for
EMERGENCY OFF is not
included.
---
---
Legend plate for
EMERGENCY STOP is not
included.
---
10
2
0.6
0.2
(resistive
DC12
load)
Classification
Certified Standards
Note: Only models with NC contacts have a direct opening mechanism.
*1. UL-certification for CSA C22.2 No. 14 and bears the
*2. Some models have been certified.
Note: 1. Rated current values are determined according to the
LED Indicators without Voltage Reduction Unit
UL *1
TÜV SÜD
CQC (CCC)
KOSHA *2
6 VAC/VDC
12 VAC/VDC
24 VAC/VDC
Certification body
Certification has been obtained for the Switch Unit and the Lamp
Socket.
Rated voltage
2. Minimum applicable load: 10 mA at 5 VDC
A22Z-EG1
A22Z-EG10
A22Z-EG1-W
A22Z-EG10-W
A22Z-EG2
testing conditions. The above ratings were obtained by
conducting tests under the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
Model
UL508, C22.2 No.14
EN60947-5-1,
EN60947-5-5
(certified direct
opening mechanism)
GB14048.5
EN60947-5-1
8 mA
Rated current
Provides SEMI-S2/SEMATECH
Application Guide for SEMI-S2
compatibility. The SEMI-S2-compatible
Shroud and legend plate for
EMERGENCY OFF come as a set. Use
with an A22E Emergency Stop Switch.
(for emergency shutoff) *
Provides SEMI-S2/SEMATECH
APPLICATION GUIDE FOR SEMI S2
compatibility. Use with an A22E with
EMO indication. (for emergency off)
Provides SEMI-S2/SEMATECH
Application Guide for SEMI-S2
compatibility. The SEMI-S2-compatible
Shroud and legend plate for
EMERGENCY STOP come as a set.
Use with an A22E Emergency Stop
Switch. (for emergency stop) *
Provides SEMI-S2/SEMATECH
APPLICATION GUIDE FOR SEMI S2
compatibility. Use with an A22E with
EMS indication. (for emergency stop)
SEMI-S2/SEMATECH Application
Guide for SEMI S2-compatible Shroud.
(for emergency shutoff) *
Use together with an A22E Emergency
Stop Switch.
Standards
Remarks
6 VAC/VDC±5%
12 VAC/VDC±5%
24 VAC/VDC±5%
E41515
Inquire
2003010303070635
2004-220, 2007-27
Operating voltage
File No.
A22E
mark.
8

Related parts for A22E-M-02B