GSM15-5 SL Power ( Ault / Condor ), GSM15-5 Datasheet - Page 2

no-image

GSM15-5

Manufacturer Part Number
GSM15-5
Description
Power Supply, Switcher; 15 W; Single Output; 5.1 V; 2.35 A (Typ.);
Manufacturer
SL Power ( Ault / Condor )
Type
Medicalr
Datasheet

Specifications of GSM15-5

Brand/series
GSM15 Series
Configuration
Open-Frame
Current, Input
Maximum input current at 90 Vac, 60 Hz with full rated output load not to exceed 0.6 A.
Current, Inrush
The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A.
Current, Leakage
128 uA (Nom.)(Class I)
Current, Output
2.35 A (Typ.)
Dimensions
3.00 in. L x 2.10 in. W x 0.92 in. H
Mounting Type
Panel
Noise, Output
0.5% rms, 1% Pk-Pk, 20 MHz Bandwidth
Number Of Outputs
1
Operation
Switching
Output
5.1 VDC @ 2.35 A
Output Type
Single Output
Overvoltage Protection
Built in OVP on all models. Approximately 120-140% of output voltage.
Power Rating
15 W
Power, Output
15 W
Primary Type
AC-DC
Regulation, Total
2
Standards
UL Listed 2601-1, IEC60601-1, CSA Certified, EN60601-1 and CE Marked to LVD
Voltage, Input
90 to 264 VAC
Voltage, Output
5.1 VDC
Notes:
A. Rating with unrestricted convection cooling.
B. Peak Power for 60 sec. 10% duty cycle or continuous rating with 150 LFM of airflow.
C. Output voltages preset at factory, not user adjustable.
D. Add “G” suffix to model nuber for RoHS compliant model.
GSM15 MECHANICAL SPECIFICATIONS
Medical
Model
GSM15-5
GSM15-12
GSM15-15
GSM15-24
GSM15-28
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
INPUT: J1 AMP P/N 640456-4
PIN 1) AC LINE
PIN 2) N/C
PIN 3) N/C
PIN 4) AC NEUTRAL
GND: 0.098 DIA. THRU HOLE
OUTPUT: J2 AMP P/N 640456-4
PIN 1) COMMON Return
PIN 2) COMMON Return
PIN 3) OUTPUT #1 + Vout
PIN 4) OUTPUT#1 +Vout
MATING CONNECTOR AMP P/N
MTA – 100 Recepticle
NOTE: 3A MAXIMUM RECOMMENDED
CURRENT PER CONNECTOR PIN
Voltage
Output
5.1 V
12 V
15 V
24 V
28 V
OPERATING
0 to 50° C
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
Min.
0 A
0 A
0 A
0 A
0 A
pk
rms’
0.003 g
2
/Hz
Normal (A)
0.625 A
2.35 A
1.25 A
0.54 A
1.0 A
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
rms’
pk
0.026 g
2
/Hz
76.20mm x 53.34mm x 23.37mm
Peak (B)
0.75 A
0.64 A
1.5 A
1.2 A
Weight: 0.25 LBS. [.113 kg]
3 A
3.00 x 2.10 x .92 inches
Overall Dimensions:
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
MAX.
Initial Set
Point
2.5%
2.5%
2.5%
2.5%
2.5%
OVP Setpoint
280 V
7.2 V
16 V
21 V
32 V
Regulation
Total
2%
2%
2%
2%
2%
Ripple and
Noise
1%
1%
1%
1%
1%

Related parts for GSM15-5