E32-D51 Omron Automation, E32-D51 Datasheet - Page 4

no-image

E32-D51

Manufacturer Part Number
E32-D51
Description
Sensor, Fiber Unit, Heat Resistant, 35mm Permissible Bending Radius
Manufacturer
Omron Automation
Type
Fiber Opticr
Datasheet

Specifications of E32-D51

Brand/series
E32
Function
Fiber Optic
Ip Rating
IP67
Primary Type
Photoelectric
Range, Measurement
400 mm
Sensing Mode
Reflective
Technology
Photoelectric
Termination
Screw
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E32-D51
Manufacturer:
FSC
Quantity:
4 000
Convergent-reflective Models
E32-L86
Heat-resistant Models
E32-D51
E32-D81R-S
E32-D81R
E32-D61-S
E32-D61
E32-D73-S
E32-D73
Chemical-resistant Models
E32-D12F
46
Fiber Units with Reflective Sensors
Note: The maximum allowable temperature is 150 C. The maximum
7
10
16
Fiber: 1.2 dia.
1 dia.
Sensing head: 6 dia.
1.4 dia. M4 × 0.7
10
Two, 1.5 dia.
allowable temperature for continuous operation is 130 C.
M4 × 0.7
3
3.1
4.9
3
Stainless-steel tube:
1.25 dia.
5
2
20
2
Two toothed washers (SUS)
20
1.65 dia.
60
2.4
3
Two hexagonal nuts
Two toothed washers
Sensing head: M6 × 0.75 *1
2.4
5 *4
17
5
13
3
2.5 dia.
Two hexagonal nuts
5 dia. *3
Two hexagonal nuts (SUS)
Sensing head: M6 × 0.75 *1
5
Fluororesin
2,000
Two toothed washers
A
Sensing head: M6 × 0.75*
Protective tube (gray)
(70)
A
A
20
3.5 dia.
Two hexagonal nuts
Optical axis
Two toothed washers
Sensing head: M4 × 0.7 *1
(4.2 dia.)
Two, 4 dia.
2.4
2,000
2,000
8.9
10
4 dia.
SUS flexible tube
Using the E32-D81R-S
Using the E32-D61-S
Using the E32-D73-S
5.5
5 dia.
SUS flexible tube
18
5
5
5 dia.
5 dia.
SUS flexible tube
2,000
2,000
15
11.5
B
Optical fiber: Two, 2.2 dia.
19
2.8 dia.
15
33.5
11.5
B
*Material: Brass/nickel platin g
27
2.2 dia. Sleeve
B
10 *2
2.2 dia. Sleeve
5
11
7
10 *2
Optical fiber: Two, 2.2 dia.
5 dia.
Sensing head (stainless steel)
15
11.5
Two, 3.2-dia. holes with 6-dia. countersinks on one side
C
5
2.2 dia. Sleeve
5
100
10 *2
A
4.5
4.5
8.5
8.5
2,000
Hexagonal
caulking
5
5 dia.
3
5
*1. Material: Stainless steel (SUS303)
*3. The diameter is 6 if the fiber length exceeds 10 m.
*4. The diameter is 10 if the fiber len g th exceeds 10 m.
5
*1. Material: Stainless steel (SUS303)
4.5
5 dia.
Hexagonal caulking
5 (max.)
8.5
E32-D14F
16.5
Using the E32-D73
Using the E32-D81R
Using the E32-D61
16.5
SUS316L
Flexible tube: 2.8 dia.*1
6.5
SUS303
B
*1 Material: Stainless steel
6.5
5
B
*1. Material: Stainless steel (SUS303)
4 dia.
Sleeve
13
5 dia.
*2
Optical
axis
13 *2
2.2 dia.
16.5
SUS316L
25
B
Sleeve
13 *2
6.5
4.5
C
6.4
Sensing head: 7 dia.
Sleeve
13
*2
(26)
6.4
8
Optical-axis mark
15
8 15
6.4
Indicates models that allow free cutting.
8
Note 1. The maximum allowable tempera-
Note 1. The maximum allowable tempera-
Note: The maximum allowable temperatures
Note 1. The maximum allowable tempera-
1 5
2,000
Fluororesin tube
(protective cover)
for sections A and B are 200 C and
110 C, respectively. The section insert-
ed into the Amplifier Unit (indicated by
*2), however, must stay within the Am-
plifier Unit's operating temperature
range.
tures for sections A and B are 200 C
and 110 C, respectively. The section
inserted into the Amplifier Unit (indi-
cated by *2), however, must stay
within the Amplifier Unit's operating
temperature range.
tures for sections A and B are 350 C
and 110 C, respectively. The section
inserted into the Amplifier Unit (indi-
cated by *2), however, must stay
within the Amplifier Unit's operating
temperature range.
tures for sections A, B, and C are
400 C, 300 C, and 110 C, respec-
tively. The section inserted into the
Amplifier Unit (indicated by *2), how-
ever, must stay within the Amplifier
Unit's operating temperature range.
Optical fiber: 2.2 dia.
100

Related parts for E32-D51