119154-51 AMETEK, 119154-51 Datasheet - Page 2

no-image

119154-51

Manufacturer Part Number
119154-51
Description
ByPass Blower, 1200 W, 2stg, HF, MSC
Manufacturer
AMETEK
Type
Canisterr
Datasheet

Specifications of 119154-51

Air Flow
160 CFM
Brand/series
IntelliGen™
Configuration
Bypass
Controls
Mechanical
Current, Rating
10 A
Diameter, Inlet
1.75 "
Diameter, Outlet
1.75 "
Dimensions
145Dia x 157.23L mm
Power, Rating
1200 W
Special Features
Speed Control
Static Pressure
111 in.-H2O
Temperature, Operating, Maximum
+50 °C
Temperature, Operating, Minimum
0 °C
Termination
Terminals
Voltage, Rating
240 VAC
Weight
6 lbs.
Lead Free Status / Rohs Status
RoHS Compliant part
5.7” (145mm) DC Bypass Blower
1200 Watt, 240 Volt High Flow – IntelliGen
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
• Connections:
• Option Circuit Connections: Please consult with AMETEK for connection details for all optional and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The
performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary
depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK
reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications,
contact AMETEK Technical & Industrial Products Marketing and Sales.
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
The electronic cooling intake and exhaust must remain unobstructed.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & Industrial Products cooling air fi lters.
Note: Utilize AMETEK external EMC fi lter accessory to meet EN61000-4-6 requirement.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS
627 Lake Street, Kent OH 44240
Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
TYPICAL PERFORMANCE
65

Related parts for 119154-51