NR21 IDEC Corporation, NR21 Datasheet

no-image

NR21

Manufacturer Part Number
NR21
Description
Plug-In Base; DIN Rail Mount; NRA Series Circuit Breakers; NRA Series
Manufacturer
IDEC Corporation
Datasheet

Specifications of NR21

Brand/series
NRA Series
Mounting Type
DIN Rail Mount
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
NRA Series Circuit Breakers
www.idec.com
Protection Method
Internal Circuit
Number of Poles
Rated Voltage
Rated Tripping Currents
Rated Interrupting Capacity
Auxiliary Contact
Alarm Contact
Reference Temperature
Operating Temperature
Insulation Resistance
Dielectric Strength
Vibration Resistance
Shock Resistance
Life Expectancy
Termination
Illumination Voltage
( NRAR illuminated units)
Rocker
NRAR
NRAS
1. NRAR is not CSA certified.
2. Not suitable for branch circuit protection.
Circuit Breakers
I lluminated Rocker
(neon lamp)
NRAN
NRAR
Electromagnetic tripping
Series current trip
NRAS and NRAN: 1, 2, 3
NRAR: 1
250V AC, 50/60Hz, 65V DC
0.30A, 0.50A, 0.75A
1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A
250V AC, 50/60Hz, 1,000A
65V DC, 1,000A
SPDT microswitch 250V AC, 5A (resistive load)
50V DC, 1A (resistive load)
25°C
–40 to +85°C (avoid freezing)
100M minute (measured with 500V megger)
Between main circuit terminals: 2,000V AC, 1 minute
Between main circuit and auxiliary contact: 2,000V AC, 1 minute
100N (approximately 10G) (10 to 100Hz)
1,000N (approximately 100G)
Minimum 10,000 cycles (at 6 operations per minute)
Main terminal: Quick-connect receptacle 0.250" (accepts M3.5 screw terminal adapter)
Auxiliary contact, alarm contact: Quick-connect receptacle 0.080"
Neon: 120, 240V AC, 50/60Hz
USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC
NRA Series
Key features of the NRA series include:
• Available in 4 different styles
• Excellent overload and short circuit protection
• Small size and high-efficiency
• Life expectancy of over 10,000 operations
• UL1077 recognized “Supplementary Protectors”
• VDE certified to EN60934
license #116381
File No. E68029
NRA Series
N-3
N

Related parts for NR21

NR21 Summary of contents

Page 1

Circuit Breakers NRAS NRAN NRAR NRAR I lluminated Rocker Rocker (neon lamp) Protection Method Electromagnetic tripping Internal Circuit Series current trip NRAS and NRAN Number of Poles NRAR: 1 Rated Voltage 250V AC, 50/60Hz, 65V DC 0.30A, ...

Page 2

... With neon light 120V AC (50/60Hz) Pilot Light* With neon light 240V AC (50/60Hz) 1. For NRA series accessories, see page N-6. 2. For NRA series time delay curves, see page N-7. 3. For NRA series dimensions, see page N-10. 4. Not suitable for branch circuit protection. ...

Page 3

Circuit Breakers Time Delay Curve Descriptions Time Delay Curve AD, AA Common curves used in molded-case circuit breakers. Response to overcurrent is quite fast. Suited for protection of semiconductor circuits with BA very little overload tolerance. If overcurrents are expected ...

Page 4

... NR22 3.Not applicable for NRAR lighted series. 4.Not for use with circuit breakers incorporating 3-pole NR23 auxiliary or alarm contacts. 1-pole NR211 1-pole NUS1 2-pole NUS2 3-pole NUS3 1-pole NUS11 ...

Page 5

Circuit Breakers Internal Circuits and Terminal Arrangements: NRAS and NRAN Series Series Current Trip Series Current Trip with Auxiliary Contacts LINE LOAD Internal Circuits and Terminal Arrangements: NRAR Series Series Current Trip Series Current Trip with Auxiliary Contacts LOAD (+) ...

Page 6

NRA Series 1,000 100 10 1 0.1 0.01 100 200 300 125 Percent of Rated Current 150 1,000 AA Delay Curve 100 10 1 0.1 0.01 100 200 300 400 500 600 125 Percent of Rated Current 150 N N-8 ...

Page 7

Circuit Breakers Coil Data for Series Current Trip at 25 Rated AC Impedance DC Resistance Current (50/60Hz) Curves AA, BA, Curves AD 0.30A 9.67 9.82 0.50A 3.24 3.36 0.75A 1.45 1.49 1A 0.90 0.92 2A 0.21 0.21 3A ...

Page 8

NRA Series NRAS NRAN NRAR N N-10 www.idec.com Dimensions 0.745" 0.745" 0.745" (19.1mm) (19.1mm) (19.1mm) 1.20" (30.8mm) (30.8mm) 1-pole: 0.745" (19.1mm) 2-pole: 1.49" (38.2mm) 3-pole: 2.23" (57.3mm) 0.745" 0.745" 0.745" (19.1mm) (19.1mm) (19.1mm) 1.20" (30.8mm) 1-pole: 0.745" (19.1mm) 2-pole: 1.49" ...

Page 9

Circuit Breakers Installation Angle: Circuit breakers are designed to operate on a vertical surface. The mount- ing angle should not exceed a vertical plane by more than 10°. NRA Series NRAS 0.745" Ø0.158" (4mm) (19.1mm) Mounting Holes 0.630" (16mm) NR31, ...

Page 10

NRA Series NRT: Screw Terminal Adapter (for use with NRA Series) BNDN1000 Aluminum DIN Rail G Overall length 39.4" (1000mm) N N-12 www.idec.com Accessory Dimensions USA: (800) 262-IDEC or (408) 747-0550, Canada (888) ...

Page 11

... The electromagnetic tripping system is not affected by ambient temperature • Safe trip-free mechanism • Vibration- and impact-resistant design • When using accessories such as plug-in bases, flush plates, and colored caps, a variety of mounting styles is possible — such as DIN rail mount- ing, snap mounting into panel cut-outs, and color-coded arrangement on ...

Related keywords