CDS6004828 Cosel U.S.A. Inc., CDS6004828 Datasheet - Page 2

no-image

CDS6004828

Manufacturer Part Number
CDS6004828
Description
Converter; 28 V; 25 A; 48 VDC; 17 A (Typ.); 61 mm W x 12.7 mm H x 116.8 mm D
Manufacturer
Cosel U.S.A. Inc.
Type
Commercialr
Datasheet

Specifications of CDS6004828

Brand/series
CD Series
Configuration
Enclosed
Current, Input
17 A (Typ.)
Current, Output
25 A
Dimensions
61 mm W x 12.7 mm H x 116.8 mm D
Mounting Type
Thru-Hole
Number Of Outputs
1
Operation
Linear
Output
28 VDC @ 25 A
Power, Output
700 W
Primary Type
DC-DC Converter
Special Features
Remote Sense
Standards
cULus Recognized, TUV Approved, CE Marked
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
-20 °C
Voltage, Input
36 to 76 VDC
Voltage, Input Range
48 VDC
Voltage, Output
28 VDC
High Quality
Documented Field Failure Rate Less 0.00008%
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CDS6004828
Manufacturer:
TDK
Quantity:
26
Part Number:
CDS6004828
Manufacturer:
COSEL
Quantity:
530
Part Number:
CDS6004828
Quantity:
50
CDS
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY
OTHERS
SPECIFICATIONS
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*1
*2
*3
H-42
At rated input(DC24,DC48V) and rated load.
Ripple and ripple noise is measured by using measuring board with recommended capacitor
Co & the film capacitor 0.1mF.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
R
MODEL
VOLTAGE[V]
CURRENT[A]
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV] 190max
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V] 27.72 - 28.28 * 6 12.00 - 13.00 12.00 - 13.00 26.88 - 29.12 26.88 - 29.12 12.00 - 13.00 26.88 - 29.12
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V] 33.00 - 39.20 14.35 - 17.50
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OUTPUT-RC2 , RC3
OPERATING TEMP. , HUMID.AND ALTITUDE
STORAGE TEMP. , HUMID.AND ALTITUDE -40 to +85 C , 20 - 95%RH ( Non condensing ), 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
CDS500/600
Power module type
Io=100% 89typ ( DCIN 24V ) 83typ ( DCIN 24V ) 87typ ( DCIN 24V ) 86typ ( DCIN 24V ) 89typ ( DCIN 24V ) 89typ ( DCIN 48V ) 89typ ( DCIN 48V )
Io=50% 90typ ( DCIN 24V ) 87typ ( DCIN 24V ) 90typ ( DCIN 24V ) 87typ ( DCIN 24V ) 90typ ( DCIN 24V ) 91typ ( DCIN 48V ) 90typ ( DCIN 48V )
0 to +85 C
-20 - 0 C
0 to +85 C
-20 - 0 C
0 to +65 C 280max
-20 to +85 C 480max
* 1
* 2
* 2
* 2
* 2
* 3
* 7
CDS5002428H CDS6002412 CDS6002412H CDS6002428 CDS6002428H CDS6004812 CDS6004828
504
28V 18A
CDS5002428H CDS6002412 CDS6002412H CDS6002428 CDS6002428H CDS6004812 CDS6004828
DC18 - 36
24typ
28
18
95max
120max
160max
150max
180max
90max
200max ( DCIN 24V , Io=100% )
Fixed ( TRM pin open ), 80 - 110% adjustable by external VR or external voltage
22.40 - 32.00 * 4 * 5 10.00 - 13.75 10.00 - 13.75 * 5 22.40 - 30.80 22.40 - 32.00 * 4 * 5 10.00 - 13.75 22.40 - 32.00 * 4
Provided
Provided ( On both side of input and output )
AC500V 1minute , Cutoff current = 10mA , DC500V 50M W min ( 20 t 15 C )
AC500V 1minute , Cutoff current = 10mA , DC500V 50M W min ( 20 t 15 C )
AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( 20 t 15 C )
AC100V 1minute , Cutoff current = 100mA , DC100V 10M W min ( 20 t 15 C )
-20 to +85 C ( On aluminum base plate ), 20 - 95%RH ( Non condensing ) ( Refer to DERATING CURVE ), 3 , 000m ( 10 , 000feet ) max
10 - 55Hz , 49.0m/s
196.1m/s
UL60950-1 , C-UL , EN60950-1
61 X 12.7 X 116.8mm ( W X H X D ) / 200g max
Conduction cooling ( e.g. heat radiation from the aluminum base plate to the attached heat sink )
2
( 20G ), 11ms , once each X , Y and Z axis
600
12.5V 48A
30typ
12.5
48
40max
100max
120max
160max
150max
180max
120max
200max
40max
2
( 5G ) 3minutes period , 60minutes each along X , Y and Z axis
600
12.5V 48A
DC20.5 - 36
29typ
12.5
48
40max
100max
120max
160max
150max
180max
120max
200max
40max
*4 CDS5002428H,CDS6002428H,CDS6004828:Output voltage adjustment range is 80 - 114.3%.
*5 CDS5002428H,CDS6002412H,CDS6002428H:When the output voltage adjustment range is
*6 Aluminum baseplate temperature Tc=25C
*7
1
101% or more,the input voltage range is limited(Refer to Instruction Manual).
Please consult us in regard to use from -40C.
CD
Ordering information
616
28V 22A
DC18 - 36
30typ
28
22
95max
190max
120max
160max
150max
180max
280max
480max
90max
33.00 - 39.20
2
S
3
600 48
616
28V 22A
DC19 - 36
29typ
28
22
95max
190max
120max
160max
150max
180max
280max
480max
90max
4
700
12.5V 56A
DC36 - 76
17typ
12.5
56
40max
100max
120max
160max
150max
180max
120max
200max
40max
200max ( DCIN 48V , Io=100% )
14.35 - 17.50 33.00 - 39.20
5
12
1Series name
2Single output
3Output wattage
4Input voltage
5Output voltage
6H :HighEfficiency
7Optional
24 :DC18 - 36V
48 :DC36 - 76V
(24VIN Model only)
M :with Mounting hole
M3 tapped
6
O
700
28V 25A
17typ
28
25
95max
190max
120max
160max
150max
180max
280max
480max
90max
7
-O

Related parts for CDS6004828