EL-USB-CO300 Lascar Electronics, EL-USB-CO300 Datasheet

no-image

EL-USB-CO300

Manufacturer Part Number
EL-USB-CO300
Description
CARBON MONOXIDE USB DATA LOGGER, 0-300PPM
Manufacturer
Lascar Electronics
Type
Loggerr
Datasheet

Specifications of EL-USB-CO300

Accuracy
±4 % of Reading
Pressure, Operating
900 to 1100 mbar
Range, Measurement
0 to 300 ppm CO
Repeatability
±2 % of Reading
Resolution
0.5 ppm CO
Response Time
1 Minute (to Reach 90%)
Sample Rate
Every 10 Second to Every 5 Minutes
Temperature, Operating
–10(14) to 40 (104) °C (°F)
Expected Sensor Life
4 years
Lead Free Status / Rohs Status
RoHS Compliant part
SpeciÀ cations liable to change without prior warning
EL-USB-CO300
EL-USB-CO300
Carbon Monoxide (CO) Data
Carbon Monoxide (CO) Data
Logger with USB Interface
Logger with USB Interface
FEATURES
• 0 to 300 ppm CO measurement range
• Stores up to 32,510 measurements
• User-programmable warning threshold with bright
• USB interface for set-up and data download
• Expected sensor life: 4 years
• Supplied with replaceable internal
This standalone data logger measures and stores up to 32,510 Carbon
Monoxide (CO) readings over a 0 to 300 ppm measurement range and
-10 to +40°C (14 to +104°F) operating temperature range. The user
can easily set up the logging rate and start time, and download the
stored data by plugging the module straight into a PC’s USB port and running the purpose designed software under Windows 2000, XP and
Vista (32-bit). The data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a long-life
lithium battery. Data is stored in non-volatile memory and is not lost when the battery is empty. A bright red LED will Á ash and a buzzer can
sound when a preset warning level has been exceeded.
IMPORTANT SAFETY WARNING
DO NOT ATTEMPT TO USE THE EL-USB-CO300 WITHOUT READING AND UNDERSTANDING THE DOCUMENTATION. CARBON MONOXIDE
MONITORING IS A COMPLEX PROCEDURE. IF THERE IS ANY DOUBT AS TO THE SAFETY OR APPLICATION - STOP! CONSULT A QUALIFIED
EXPERT.
The EL-USB-CO300 is a professional measuring instrument, designed to record Carbon Monoxide (CO) gas levels for later analysis. It is not
an alarm/safety/warning device and should not be used in this capacity for the following reasons:
Carbon Monoxide is poisonous. It is a clear, colorless gas that has no smell or taste and can be lethal even in very low concentrations.
It can injure or kill people and animals who are not adequately warned of its presence.
In areas where the safety of humans and animals is a concern we insist that a domestic or industrial CO detector/alarm, designed to a
nationally approved quality standard, with features such as a high decibel alarm or siren and a clear visual warning, speciÀ cally designed
to provide adequate warning of dangerous CO levels, be installed, used and maintained.
1. The lights and sound emitted by the EL-USB-CO300 to indicate a high level of CO do not provide adequate warning to those in the
2. The battery life of the EL-USB-CO300 during audible and visual indication of a high level of CO will rapidly diminish and will therefore
3. The EL-USB-CO300 takes a sample reading at intervals as set by the user for recording/monitoring/analysis purposes. Dangerous
4. Due to the limitations of the device as a professional instrument, it is left to the user to set the light and sound alarms indicating
visual and audible warnings
lithium battery and Windows control software
surrounding area that a high level of CO has been recorded.
only be active for a short period of time.
levels of CO will not register with the device until a sample reading is taken.
the presence of CO. Therefore the instrument can be set up to provide NO form of warning.
www.lascarelectronics.com
Issue 2
10/09
S.C
ORDERING INFORMATION
Standard Data Logger
(Data Logger, Software on
CD, Battery)
Replacement Battery
Applies to EL-USB-CO300
EL-USB-CO300
BAT 3V6 1/2AA
Page 1 of 5

Related parts for EL-USB-CO300

EL-USB-CO300 Summary of contents

Page 1

... The EL-USB-CO300 is a professional measuring instrument, designed to record Carbon Monoxide (CO) gas levels for later analysis not an alarm/safety/warning device and should not be used in this capacity for the following reasons: 1. The lights and sound emitted by the EL-USB-CO300 to indicate a high level not provide adequate warning to those in the surrounding area that a high level of CO has been recorded. ...

Page 2

... EL-WIN-USB (CONTROL SOFTWARE) Lascar’s EasyLog USB control software is supplied free of charge with the EL-USB-CO300. Easy to install and use, the control software runs under Windows 2000, XP (Home and Professional Editions) and Vista (32-bit). The software allows the user to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be conÀ ...

Page 3

... LED FLASHING MODES EL-USB-CO300 features a red and a green LED. The LEDs on an EL-USB-CO300 will Á ash in one of the following ways, assuming hold of the warning threshold has been turned off in the EL-WIN-USB control software. By default hold is disabled. In this mode the red LED will no longer continue to Á ash after the logged reading has returned to normal from an alarm condition. Hold can be turned on via the control software. In this mode the red LED that indicates an alarm condition will continue to Á ...

Page 4

... Before replacing the battery, remove the EL-USB-CO300 from the PC. Note: Leaving the EL-USB-CO300 plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. ...

Page 5

... CR1620 1 month Lithium coin cell 7 days N/A N/A UNIT NOS. 6-8, 19/F Futura Plaza 111-113 How Ming Street Kwun Tong, Kowloon HONG KONG T +852 2389 6502 F +852 2389 6535 E saleshk@lascar.com.hk Applies to EL-USB-CO300 Page ...