1140-G151-P7M1-15A E-T-A Circuit Protection and Control, 1140-G151-P7M1-15A Datasheet - Page 2

no-image

1140-G151-P7M1-15A

Manufacturer Part Number
1140-G151-P7M1-15A
Description
Circuit Breaker; Therm; Push; Cur-Rtg 15A; Panel; 2 Pole; Vol-Rtg 240/48VAC/VDC
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 1140-G151-P7M1-15A

Actuator Type
Push
Brand/series
1140 Series
Characteristic
Medium Delay
Current, Rating
15 A
Dimensions
0.748"Lx0.433"Wx1.95"H
Mounting Hole Size
0.35x0.378 "
Mounting Type
Panel
Number Of Poles
2
Termination
Blade
Voltage, Rating
240/48 VAC/VDC
Miniaturised double pole thermal circuit breaker with push-to-reset
tease-free, trip-free, snap action mechanism (R-type TO CBE to EN
60934). Threadneck panel mounting. Suitable for line and neutral
switching - the thermal actuator operating on one pole simultaneously
opens both poles under overload conditions. Approved to CBE
standard EN 60934 (IEC 60934).
Motors, transformers, solenoids, hand-held machines and appliances.
Especially suited to AC duties where the correct orientation of line/
neutral is not known/cannot be guaranteed.
Type No.
1140
1140 - G1 5 1 - P7 M1 - 16 A
*mounting hardware bulk shipped
Current
rating (A)
0.05
0.06
0.08
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
1.2
1.5
Authority
VDE
CSA, UL
Kema (EN 60934)
Description
Typical applications
Ordering information
Standard current ratings and typical internal resistance values
Approvals
Mounting
G1
G4
double pole threadneck panel mounting
threadneck panel mounting 3/8-27UNS, with hex nut and
knurled nut*
threadneck panel mounting 3/8-27UNS, with knurled nut*
Number of poles
5
double pole, 1-pole protected
Actuator style
1
Internal
resistance (Ω)
345
240
142
88
24
9.9
5.9
3.7
2.2
1.9
1.4
0.9
0.6
0.5
black push button (standard)
Terminal design
P7
blade terminals DIN 46244-C (QC 2x.110)
Characteristic curve
M1
Thermal Overcurrent Circuit Breaker 1140-... (2-pole)
Voltage ratings
AC 240 V; DC 48 V
AC 250 V; DC 50 V
AC 240 V; DC 48 V
medium delay
Current ratings
0,05...16 A
ordering example
Current
rating (A)
1.8
2
2.5
3
3.5
4
5
6
7
8
10
12
15
16
Current ratings
0.05...16 A
0.05...16 A
0.05...16 A
Internal
resistance (Ω)
0.3
0.3
0.2
0.1
0.08
0.07
0.05
0.04
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
For further details please see chapter: Technical Information
Voltage rating
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 606664 A) withstand voltage
Dielectric strength
(IEC 60664 and 60664A)
Insulation resistance
Interrupting capacity I
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40 050)
Vibration
Shock
Corrosion
Humidity
Mass
Technical data
AC + DC
operating area
pole/pole
0.05...3 A 300 operations at 2 x I
3.5...8 A
9...16 A
cn
-20...+60 °C (-4...+140 °F) T 60
AC 240 V; DC 48 V
(UL: AC 250 V; DC 50 V)
0.05...16 A
3,000 operations at 2 x I
200 operations at 2 x I
1,000 operations at 2 x I
100 operations at 2 x I
rated impulse
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.05...3 A
3.5...8 A
10...16 A
I
0.05...16 A
0.05...7 A
8...16 A
operating area IP40
terminal area IP00
10 g (57-500 Hz) ± 0.76 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-3, test Ca
approx. 13 g
N
1140-G.5
6 x I
8 x I
120 A
U
DC 50 V
AC 250 V
AC 250 V
N
N
N
N
N
N
pollution
degree
2
, inductive
, inductive
, inductive
N
N
, resistive
, resistive
200 A
1,000 A
2,000 A
1 - 33
1