LDA300W-24-SNF Cosel U.S.A. Inc., LDA300W-24-SNF Datasheet - Page 2

no-image

LDA300W-24-SNF

Manufacturer Part Number
LDA300W-24-SNF
Description
Power Supply; 85 to 132 VAC; 24 V; 14 A; 336 W (Max.); 47 to 440 Hz; LDA Series
Manufacturer
Cosel U.S.A. Inc.
Type
Industrialr
Datasheet

Specifications of LDA300W-24-SNF

Brand/series
LDA Series
Configuration
Enclosed
Current, Output
14 A
Dimensions
108 mm W x 50 mm H x 255 mm D
Frequency, Input
47 to 440 Hz
Mounting Type
Panel
Number Of Outputs
1
Operation
Linear
Output
24 VDC @ 14 A
Power, Output
336 W
Power, Rating
336 W (Max.)
Primary Type
AC-DC
Special Features
Remote Sense
Standards
UL1950, cUL, EN60950, VDE0160 Complies with DEN-AN and IEC60950
Temperature, Operating
-10 to +70 °C
Voltage, Input
85 to 132/170 to 264 VAC
Voltage, Output
24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
LDA
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
SPECIFICATIONS
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*1
*2
*3
*
*
E-48
Peak load for 30sec. or less is acceptable if the total wattage is less than the rated wattage.
This is the value that measured on measuring board with capacitor of 22mF within 150mm from output terminal.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
R
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV] 60max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP. , HUMID.AND ALTITUDE -10 to +70 C , 20 - 90%RH ( Non condensing ) ( Refer to DERATING CURVE ) 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -20 to +75 C , 20 - 90%RH ( Non condensing ) 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
R
LDA300W
Rugged PCB type
ACIN 100V 7.5typ ( Io=100% )
ACIN 200V 4.5typ ( Io=100% )
ACIN 100V 72typ
ACIN 200V 74typ
ACIN 100V 15/30A typ ( Primary/Secondary Surge Current ) Io=100% ( More than 3sec.to re-start )
ACIN 200V 30/30typ ( Primary/Secondary Surge Current ) Io=100% ( More than 3sec.to re-start )
Forced air 60
Convection
0 to +50 C
-10 - 0 C
0 to +50 C
-10 - 0 C
* 1
* 2
* 2
* 2
* 2
* 3
LDA300W-3 LDA300W-5 LDA300W-9 LDA300W-12 LDA300W-15 LDA300W-18 LDA300W-24 LDA300W-30 LDA300W-48
180
3V 60A
LDA300W-3 LDA300W-5 LDA300W-9 LDA300W-12 LDA300W-15 LDA300W-18 LDA300W-24 LDA300W-30 LDA300W-48
AC 85 - 132 / 170 - 264 1 f
47 - 440
0.75max ( 60Hz , According to UL , CSA , VDE and DEN-AN )
3
40 ( 60 )
20max
40max
80max
140max
120max
160max
20max
200max ( ACIN 100V , Io=100% )
10typ ( ACIN 85V , Io=100% ) 20typ ( ACIN 100V , Io=100% )
4.00 - 5.25V Works at 115 - 140% of rating
Not provided
Provided
Option ( Refer to Instruction Manual )
AC3 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( At Room Temperature )
10 - 55Hz , 19.6m/s
196.1m/s
UL60950-1 , C-UL , EN60950-1 , EN50178 Complies with DEN-AN and IEC60950-1
Complies with FCC-B , CISPR22-B , EN55022-B , VCCI-B
108 X 50 X 255mm ( W X H X D ) /1kg max ( without terminal block )
Convection / Forced air ( Refer to DERATING CURVE )
2
( 20G ), 11ms , once each X , Y and Z axis
300
5V 60A
78typ
81typ
5
60
40 ( 60 )
20max
40max
80max
140max
120max
160max
60max
20max
5 , 9 , 12 , 15 , 18 , 24 , 30 , 48V t 10%
2
( 2G ), 3minutes period , 60minutes each along X , Y and Z axis
306
9V 34A
78typ
81typ
9
34
23 ( 34 )
36max
100max
120max
160max
150max
180max
120max
36max
324
12V 27A
80typ
83typ
12
27
17 ( 27 )
48max
100max
120max
160max
150max
180max
150max
48max
1
LDA 300
Ordering information
22
14 ( 22 )
330
15V 22A
81typ
84typ
15
60max
120max
120max
160max
150max
180max
180max
60max
2
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
Recommended Noise Filter
NAC-16-472
306
18V 17A
81typ
84typ
18
17
12 ( 17 )
72max
120max
120max
160max
150max
180max
200max
72max
3
W
336
24V 14A
83typ
86typ
24
14
9 ( 14 )
96max
150max
120max
160max
150max
180max
290max
96max
4
-5
1Series name
2Output wattage
3Autoranging input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
L :with LED
R :with Remote ON/OFF
S :with Chassis
SNF :with Chassis & cover
T :Vertical terminal block
5
300
30V 10A
83typ
86typ
30
10
7 ( 10 )
120max
180max
120max
160max
150max
180max
360max
120max
& fan
-O
302.4
48V 6.3A
83typ
86typ
48
6.3
4.2 ( 6.3 )
192max
240max
150max
200max
400max
600max
560max
192max

Related parts for LDA300W-24-SNF