ET616 Grasslin, ET616 Datasheet - Page 3

no-image

ET616

Manufacturer Part Number
ET616
Description
Timer; 20 A @ 125 VAC; 120 to 277 VAC @ 50/60 Hz; 1000 W @ 120 VAC (Tungsten)
Manufacturer
Grasslin
Type
Digital Timerr
Datasheet

Specifications of ET616

Mounting Type
Wall
Power, Rating
800/1200 W
Primary Type
Controller
Standards
UL, cUL
Temperature, Operating, Maximum
38 °C
Temperature, Operating, Minimum
-18 °C
Termination
Lead Wires
Voltage, Supply
120/277 VAC
Ratings
Inductive, @ 20 A, 125 VAC, 50/60 Hz 10 A, 250 and 277 VAC, 50/60 Hz
Motor
1 HP, 125 VAC, 50/60 Hz 2 HP, 250 VAC, 50/60 Hz
Approvals
UL, CSA
For Use With
Lighting Control
ElECTRONIC INTERVAl/COuNTdOWN
TImER OPERATINg INSTRuCTIONS
The ET616 is a wall mounted Electronic Time
Switch which automatically turns lights or other
loads off after a preset time period. When used
for control of lights in a conference room, rest
room, or similar temporary use room, it functions
like a standard light switch, turning the lights
ON when the button is pressed, and OFF when
pressed again. If left ON, it will automatically go
off after a time period settable from 1 minute to
12 hours via tamper-proof DIP switches. It is also
suitable for the control of tanning beds, fans,
heaters, chemical pumps, laboratory apparatus,
and other applications requiring a preset ON time
and automatic shutoff.
FEATuRES
• Operates on either 120V or 277VAC (50/60Hz)
• Mounts in standard wallbox with Decorator style wall plate, single or
• Easy installation – Installs in minutes
• Single button ON/OFF operation
• Automatic shutoff after preset time period
• Backlighted LCD displays countdown time
• Display Flashes, and Audible Beep 1 minute before
• If button is pressed during last minute of countdown, switch remains on
• Preset time adjustments; 5, 15, 30, 60 minutes, 3, 6, 9, 12 hours
• Time scrolling option adjusts time up or down
• Switch holds position during a power failure (ON or OFF), restarts at pre-
• UL and CUL Listed
ET 616
NOTE:
necessary to press the RESET button.
multi-gang
time-out
and timer is reset
set time when power is restored
On initial installation or after prolonged power failure, it is
SPECIFICATIONS
Input Voltage: 120V or 277VAC (50/60 Hz)
Timing Intervals: 5, 15, 30, 60 minutes
Switch Ratings:
At 120VAC:
At 277VAC:
Operating Temperature:
0° to 100°F (–18° to 38°C)
Operating Humidity:
0-95% RH Non-Condensing
Faceplate Color: White
Timing Accuracy: Less Than 1% Deviation
Wiring Connections: 6” Lead wires
3, 6, 9, 12 hours
1,000W Tungsten
800W Ballast
8.3A Resistive
1,500W Tungsten
1,200W Ballast
5.4A Resistive