TL4019-30241F1M
Manufacturer Part Number
TL4019-30241F1M
Description
SWITCH, FLEX1 ACTUATOR, 24VAC/DC, 2 N/C+1N/O+1N/O, 3XM20 W/NPT ADAPTER
Manufacturer
Sti (Scientific Technologies, Inc.)
Type
Interlockr
Datasheet
1.TL4019-30241F1M.pdf
(8 pages)
Specifications of TL4019-30241F1M
Actuator Type
Key
Contact Form
2 NC/NO
Current, Rating
4 A
Function
Safety
Ip Rating
IP67
Mounting Type
Door
Termination
M20 + NPT Adapter
Voltage, Rating
230/24 VAC/VDC
G
TL4019
■
sliding guard doors and swinging
guard doors that must remain
locked until a signal is applied to
the internal solenoid that unlocks
the guard door.
■
SR223SMT Timer Unit
Used with the TL4019 for machines with constant
overrun. Gives a timed delay to the lock/release
signal. Failsafe and adjustable to a range of
times from 1.0 seconds up to 31 seconds.
G186
✎
✎
Applications
Typical applications are on
Application
Monitoring Units
For a wiring example of the TL4019 switch
with a SR209AD delayed output safety
monitoring relay see “Common Circuit
Examples” in the Engineering Section of
this catalog.
For information on these Safety
Monitoring Relays, see page H1.
■
Specifications are subject to change without notice.
Note: The safety contacts of the Omron STI switches are described as normally closed (N/C)—i.e.,
SR125SMS Stop Motion
Sensing Unit
Used with the TL4019 for machines with
inconstant or variable overrun. Senses back EMF
of AC or DC motors. Failsafe and adjustable to a
range of 0.01 V to 0.10 V.
electrical
mechanical
environmental
compliance
Specifications
Safety contacts:
Auxiliary contacts:
Switching Ability
Safety contact material:
minimum current:
Solenoid Supply Voltage:
Solenoid Power:
Solenoid rating:
mounting:
mounting hardware:
min Operating radius:
max holding force:
max Actuation Speed:
case material:
Actuator material:
Wiring entry:
Weight:
color:
mechanical life:
Protection:
Operating temperature:
cleaning:
Standards:
Approvals/listings:
with the guard closed, actuator in place, and the machine able to be started.
Ac:
Dc:
All models
230 V – 4 A
24 V – 4 A
Silver alloy with gold flash
24 V 1 mA
24 VAC/DC or 110 VAC (all -15% / +10%)
8 W
100% duty
Any position
4 x M5 screws (not supplied)
Approximately 100 mm (3.9 in.) with flex actuators
Approximately 1000 mm (39 in.) with flat and 90-degree actuators
1200 N (270 lb.)
20 m/min.
Reinforced thermoplastic
Stainless steel
3 x M20 conduit with 0.5 in. NPT adapter
500 g (17 oz.)
Red
1 x 10
IP67 (NEMA 6)
-20 to 55°C (-4 to 131°F)
Water washdown
EN1088, EN292, EN60947-5-1, EN60204-1
CE marked for all applicable directives, UL and C-UL, BG
6
minimum
tl4019-1 & -2
2 N/C
2 N/O
Safety Monitoring Relay Units
Safety monitoring relays ensure a maximum level of
safety by monitoring all wiring in the safety circuit,
including switches and contactors. Any fault and the
power to the machine is switched off. A variety of
safety monitoring relay units are available.
tl4019-3 & -4
2 N/C
1 N/O + 1 N/O
1 N/O + 1 N/C
1 N/C + 1 N/O
N
A
Go to the Engineering Guide
For in-depth information on
safety standards and use.
For More Guarding Products
See Section N for safeguarding
cutting and turning machines
tl4019-5
1 N/C
1 N/C + 1 N/O