H7CN-XLN AC100-240 Omron Automation, H7CN-XLN AC100-240 Datasheet - Page 3

no-image

H7CN-XLN AC100-240

Manufacturer Part Number
H7CN-XLN AC100-240
Description
Counter, Up Count, 30CPS, SPST, 100 - 240 Vac
Manufacturer
Omron Automation
Datasheet

Specifications of H7CN-XLN AC100-240

Brand/series
H7CN
Connection
8 Pin Round Socket
Features
Memory Protect Circuit
Function
Up Counting, 30cps
Mounting Type
DIN Rail
Output
SPST-NO Contact
Supply Voltage
100 to 240 VAC
Single Counting Speed Per Model
30 cps or 5 kcps
Engineering Data
H7CN
Supply voltage
Operating voltage range
Power consumption
Max. counting speeds (CP1, CP2)
Minimum pulse widths
Approvals
Ambient operating temperature
Storage temperature
Ambient operating humidity
Insulation resistance
Dielectric strength
Vibration Mechanical durability
Shock
Service
Service
life
life
Weight
1000
500
100
RATINGS
ELECTRICAL SERVICE LIFE
CHARACTERISTICS
0
0
250 VAC (p.f. = 1)
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
1
Load current (A)
30 VDC (p.f. = 1)
2
AC
DC
3
100 to 240 VAC, 50/60 Hz
85 to 110% of rated voltage
30 cps with contact and solid-state inputs; 5,000 cps with solid-state inputs only
16.7 ms at 30 cps (ON/OFF ratio of 1:1)
12 to 48 VDC (20% max. ripple)
Approx. 12 VA/2.5 W at 240 VAC, 50 Hz
Approx. 2.5 W at 48 VDC
0.1 ms at 5 kcps (ON/OFF ratio of 1:1)
UL / CSA
-10 to 55 C (14 to 131 F)
-25 to 65 C (-13 to 149 F)
35 to 85% RH
100 m minimum at 500 VDC
2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed
metal parts, between power supply circuit and control output circuit
10 to 55 Hz, 0.75 mm (0.03 in) double amplitude
10 to 55Hz, 0.5 mm (0.02 in) double amplitude
Approx. 30 G
Approx. 10 G
10 million operations minimum under no load at 1,800 operations/hour switching frequency
100,000 operations minimum under resistive load at 3 A, 250 VAC (p.f. = 1)
150 g (5.3 oz.)
1000
500
100
0
0
250 VAC (p.f. = 0.4)
3
1
30 VDC (L/R = 7 ms)
Load current (A)
2
3
Note:
The service life graphs apply
to all relay output models.
They do not apply to solid-
state output models H7CN-
XHNS or H7CN-YHNS.
H7CN