53230A Agilent Technologies Test Equipment, 53230A Datasheet - Page 7

no-image

53230A

Manufacturer Part Number
53230A
Description
Universal Frequency Counter/Timer, 350 MHz, 12 digit/sec, 20 ps
Manufacturer
Agilent Technologies Test Equipment
Type
Counter/Timerr
Datasheet

Specifications of 53230A

Frequency Range
DC coupled 1 mHz to 350 MHz; AC coupled 10 Hz to 350 MHz
Input Impedance
Selectable 1 MΩ ±1.5% or 50Ω ±1.5%
Input Type
Front panel BNC
Input, Range
±5 V (± 50 V) full scale ranges
Noise
500 μVrms (max), 350 μVrms (typ)
Number Of Channels
3 Channels
Sensitivity
DC - 100 MHz: 20 mVpk > 100 MHz: 40 mVpk
1. Maximum display resolution for frequency. Totalize display resolution is 15 digits, time interval is 12 digits.
2. Continuous, gap-free measurements limits the gate time setting to 10 µs to 1000 s in 10 µs steps.
3. Refer to the gate characteristics section for more details on advanced gate capabilities.
4. Measurements on each input channel are performed simultaneously using one gate interval. The actual measurement gate interval
5. Maximum sample rate. Actual sample rate will be limited by the input signal edge rate for signals slower than the selected sample
6. Assumes two frequencies are identical, only shifted in phase.
7. Manual control of gate width and gate delay are allowed only for wide pulsed mode.
8. For pulsed signals > -7 dBm (100 mVrms) while gated on.
9. For totalize, time interval and frequency measurements, you may get measurement readings beyond the
10. Applies when burst width * Carrier Freq >80.
11. Specifications apply if measurement channels are in 5 V range, DC coupled, 50 ohm terminated and at fixed level for: time interval
12. Option 150 microwave pulse/burst measurement descriptions:
Measurement Characteristics
Pulse/burst frequency and pulse envelope detector (Option 150)
Pulse/burst measurements
Pulse/burst width
for carrier frequency
measurements
Minimum pulse/burst
width for envelope
measurements
Acquisition
PRF, PRI range
Pulse detector response
time (typ)
Pulse width accuracy (typ)
(0 dbm, 23º C)
Power ratio (typ)
Pulse measurement
sensitivity (typ)
on each channel will be synchrounous with edges of each input signal.
rate.
range stated, but the accuracy of those readings is not specified.
single and dual channel, pulse width, duty, phase, single period and rise/fall time measurements.
amplitude
- 6 dB
p-p
8
+ width burst (on)
10
-6 dB Detector Level
PRI = 1/PRF
Burst carrier frequency
PRF
- width burst (off)
53210A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
continued
+ width burst (on)
-6 dB Detector Level
7
PRI = 1/PRF
PRF
12
Burst carrier frequency
53220A
- width burst (off)
- 12 dB
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
interval (PRI), pulse repeti-
tion frequency (PRF), posi-
20 ns + (2*carrier period)
Carrier frequency, carrier
tive and negative width
period, pulse repetition
-13 dBm (50 mVrms)
>50 ns – 1000 s
Narrow: <17 us
Auto, Manual
1 Hz – 10 MHz
15 ns rise, fall
Wide: >13 us
>200 ns
53230A
>15 dB
7