AFD40P-060AS SMC Corporation, AFD40P-060AS Datasheet - Page 2

no-image

AFD40P-060AS

Manufacturer Part Number
AFD40P-060AS
Description
Filter Element for AFD40 series Micro-Mist Separators
Manufacturer
SMC Corporation
Datasheet

Specifications of AFD40P-060AS

Product Type
Element
For Use With
AFD40 Series
Note 1) Including O-ring. Please contact SMC regarding the bowl assembly supply for
Note 2) Bowl assembly for AFD30 to AFD40-06 includes a bowl guard (steel band material).
14-2-44
Flow Characteristics
Construction
Replacement Parts
Series
AFD20
AFD30/40
Component Parts
No.
AFD20
No.
w
e
r
q
Description
Element assembly
Bowl assembly
Bowl O-ring
PSI and °F unit specifications.
Body
IN
Description
IN
Flow rate (
AFD20/30/40
Zinc die-casted
Drain
Drain
(1)
AFD20
l
ø10 One-touch fitting
/min (ANR))
OUT
Material
q
r
w
e
NBR
OUT
PC
q
r
w
e
(Representative values)
AFD30, AFD40, AFD40-06
Material
AFD20P-060AS
C2SFP-260S
Aluminum die-casted
AFD20
C2SF
N.C.
Float type auto drain (N.C.)
ø10 One-touch fitting
Float type auto-drain
AFD30P-060AS
C3SFP-260S
AFD30
C3SF
AFD30
M5 x 0.8
(2)
Part no.
AFD40P-060AS
C4SFP-260S
C4SF
AFD40
N.O.
Flow rate (
Platinum silver
(2)
Note
AFD40P-060AS
C4SFP-260S
AFD40-06
C4SF
l
/min (ANR))
(2)
1. Install a mist separator (Series AFM) as a
2. Do not install on the inlet side of the dryer as
1. Replace the element every 2 years or when the
1. Design the system so that the mist separator is
1. Do not allow air flow that exceeds the rated
2. Do not use in a low pressure application (such
Be sure to read before handling.
Refer to pages 14-21-3 to 14-21-4 for
Safety
Precautions.
preliminary filter on the inlet side of the micro
mist separator to prevent premature clogging.
this can cause premature clogging of the
element.
pressure drops becomes 0.1 MPa, whichever
comes first, to prevent damage to the element.
installed in a pulsation-free location. The
difference between internal and external
pressure inside the element should be kept
within 0.1 MPa, as exceeding this value could
cause damage.
flow. If the air flow is allowed outside the range
of the rated flow even momentarily, drainage
and lubricant may splash at the outlet side or
cause damage to the component.
as a blower). F.R.L. unit has its own minimum
operating
equipment and is designed specifically to
function with compressed air. If used below the
minimum operating pressure, a loss of
performance and malfunction can occur.
Please contact SMC if an application under
such conditions cannot be avoided.
Caution
Warning
Caution
Caution
AFD40
Instructions
Precautions
pressure
Maintenance
Air Supply
Selection
Design
Flow rate (
depending
and
: When saturated with oil
: Initial state
l
/min (ANR))
Common
on
the