229-2 12267 Simpson, 229-2 12267 Datasheet

no-image

229-2 12267

Manufacturer Part Number
229-2 12267
Description
Tester, Current; 30 V; 3%; 1500 Ohms Shunted by 0.15 F
Manufacturer
Simpson
Datasheet

Specifications of 229-2 12267

Accuracy
±3%
Battery Type
One 9-volt battery NEDA type
Impedance, Input
1500 Ohms Shunted by 0.15 F
Measuring Range
30 V
Standards
accordance with the latest applicable national standards.
AC Current Leakage Tester
Small leakage currents can be dangerous! The current above the "threshold of
perception" in appliances, motors and other equipment can cause a violent reaction
which may result in serious physical injury. For service, lab, production or industry,
the Model 229-2 helps determine product conformance to standards.
CAUTION! Leakage current in appliances may increase with use and aging. Check
appliances periodically for safety.
• Designed around ANSI C39.5 requirement for the measurement of AC
• Compensated to Approximate Dalziel's Perception Curve
• Overload protected Up to 500 V Peak Momentarily on all ranges
• Checks both 120 VAC and 240 VAC appliances
• Includes Test Leads, Battery and Manual
Specifications
Ranges:
Short Test: Red Arc: 30 mA FS, Green arc: 10 mA or less
Resolution: 5 A on 0.3 mA range
Accuracy:
Input Impedance: For current tests, 1.5K
Input Resistance: 0.5 M for 150V Range, 1.0 M for the 300V range
Accuracy Vs. Frequency: Approximates Dalziel's "Percentile 50 Threshold of
Perception Curve" within
Battery Life: Approximately 200 hours
Rated Circuit to Ground Voltage: 300Vrms
Reference Conditions: 23C
Overload Protection: Up to 500V peak momentary on all ranges
Size: 7" x 5-1/4" x 3-1/8"
Weight: 3 Ibs. (1.4 Kg)
Battery: One 9V NEDA No. 13F, 1604A (Burgess Type PM-6 or Equivalent)
Specifications subject to change without notice.
Any discussion in this document regarding UL, ANSI or IEC specifications is
for Reference purposes only. The input network utilized in the M229-2 is
detailed in Figure 1 on Page 3 of the manual. The customer is advised to
obtain the latest specification from the rating agency.
NOTE: For specification information call ANSI at (212) 642-4900 or UL in
Northbrook, IL at (847) 272-8800.
Ordering Information
LEAKAGE TESTER
229-2 Current Leakage tester
leakage current and UL Safety Standards.
AC current: 0.3-1-3-10 mA
AC voltage: 0-150 and 0-300 volts
Battery Test: Replace-Good
3% at 60 Hz
1.0 dB
1C, 30% to 60% Relative Humidity
Catalog No.
in parallel with 0.15 F
12267
ACCESSORIES
Probe leads w/ screw-on alligator clips
Probe set, replaceable tip, banana plug
Clip set, alligator, screw on
Lead set, alligator, banana plug
229-2 Leakage Current Tester
Carrying Case accommodates the Tester, Test Leads and Operators Manual.
Catalog No.
00125
07538
00425
07500
ACCESSORIES
Case, Yellow Padded Nylon
Case, Black Padded Nylon
Case, Hard Leatherette Front Load
Case, Molded Plastic
Catalog No.
rev_2 6/09
00832
00834
00805
45028