GLC65-5G SL Power ( Ault / Condor ), GLC65-5G Datasheet - Page 2

no-image

GLC65-5G

Manufacturer Part Number
GLC65-5G
Description
POWER SUPPLY, SWITCHING; 65 W; 90 TO 264 VAC; 5.1 V; 1.7 A (MAX.); 11 A; 2%; 2%
Manufacturer
SL Power ( Ault / Condor )
Type
Commercialr
Datasheet

Specifications of GLC65-5G

Brand/series
GLC65 Series
Configuration
Open-Frame
Mounting Type
Panel
Number Of Outputs
1
Operation
Switching
Output
5.1 VDC @ 9 A
Power, Output
65 W
Primary Type
AC-DC
Special Features
Remote Sense
Voltage, Input
90 to 264 VAC
Voltage, Output
5.1 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
GLC65/GLM65 - SINGLE OUTPUT - MECHANICAL SPECIFICATIONS
* 9 A convection, 11 A with fan cooling
Commercial
Model
GLC65-5
GLC65-12
GLC65-15
GLC65-18
GLC65-20
GLC65-24
GLC65-28
GLC65-48
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
Note:
Medical
Model
GLM65-5
GLM65-12
GLM65-15
GLM65-18
GLM65-20
GLM65-24
GLM65-28
GLM65-48
OPERATING
0 to 50°
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
pk
rms’
Output
0.003 g
5.1 V
12 V
15 V
18 V
24 V
28 V
48 V
20V
2
/Hz
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
rms’
pk
9/11 A *
Current
3.25 A
1.35 A
0.026 g
5.5 A
4.3 A
3.6 A
2.7 A
2.3 A
2
/Hz
Regulation
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derate output current and total
output power by 2.5% per °C above 50°C.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1hr./
axis non-operating.
Total
2%
2%
2%
2%
2%
2%
2%
2%
V1 Adjustment
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
1.20
30.28
V1 OVP Setpoint
18.5 ± 1.5 V
21.7 ± 2.0 V
24.5 ± 2.2 V
6.2 ± 0.6 V
14 ± 1.1 V
28 ± 2.5 V
34 ± 2.8 V
55 ± 4.0 V
and Noise
Ripple
1%
1%
1%
1%
1%
1%
1%
1%

Related parts for GLC65-5G