DNC-T2610-020 NCC, DNC-T2610-020 Datasheet - Page 2

no-image

DNC-T2610-020

Manufacturer Part Number
DNC-T2610-020
Description
Dust Collector Control; 100 to 240 VAC; 50/60 Hz; Expander Module
Manufacturer
NCC
Type
Dust Collectorr
Datasheet

Specifications of DNC-T2610-020

Communication
CANbus Architecture
Current, Input
4-20 mA
Dimensions
174.63mmL×94.6mmW×38.1mmH
Mounting Type
Panel
Number Of Outputs
10
Output Type
Digital
Power, Rating
150 VA
Primary Type
Controller
Special Features
CANbus
Termination
Screw
Voltage, Supply
100 to 240 VAC
Operating Voltage
120 VAC
Each Output
200 VA Solid State TRIAC
On-time
Adjustable from 50 to 500 Milliseconds
Operating Temperature
–40°C to +70°C
SPECIFICATIONS
CORE-10
INPUTS
Supply: 100-240 VAC, 50/60Hz, 4 VA max. at
240VAC without loads
Fuse: 3A fast, 5x20 mm
 Pressure Sensor Input: 4 to 20 mA, sink/
source, programmable 10.0”, 15.0”, 25.0” w.c.
 Pressure Switch Input: Dry contact, 4 mA at
13 VDC max.
Cycle Down Switch Input: Dry contact, 4 mA at
13 VDC max.
OUTPUTS
Solenoid Outputs: 10
Output Type: Triac
Output Rating: 150 VA (at max. ON, min. OFF, 1
output selected)
Timing Accuracy: -2mS, +10 mS or +1% (which-
ever is greater), ON-time synchronized to AC line
Alarm Relay: Form-A contact, 3A at 250
VAC/30 VDC, programmable normally open or
normally closed
DISPLAY INDICATORS
3-digit 7-segment LED display, 0.56 in. red
Program Parameters/Display Status/CANbus
Status: 17 green LEDs
Alarm: 1 red/yellow LED
Output Status: 1 red/green LED
PARAMETER RANGES
ON-Time: 0.050-600 sec.
OFF-Time: 1-999 sec.
Timing Accuracy: -2 ms, +10 ms or +1% (which-
ever is greater), ON-time synchronized to AC line
Cycle Down Cycles: 1-20, none
Cycle Down Delay: 60-600 sec.
 P High Setpoint: 0-10/15/25” w.c., none
 P Low Setpoint: 0-10/15/25” w.c., none
 P High Alarm: 0-10/15/25” w.c., none
 P Low Alarm: 0-10/15/25” w.c., none
COMMUNICATIONS
Type: CANbus architecture
Terminations: Screw terminals, #12 to #28 AWG,
finger safe
ENVIRONMENTAL
Operating Temperature: -40°F to +150°F (-40°C
to +65°C)
Environmental Protection: Conformal coating
for humidity and vibration
EXPANDER-10 SPECIFICATIONS
INDICATORS
Solenoid Pulse Indication: 10 green LEDs
CANbus Status: 1 green LED
Output Status1: 1 red/green LED
OUTPUTS
Solenoids: 10 per Expansion Module
Output Type: Triac
Output Rating: 150 VA (at max. ON, min. OFF, 1
output selected)
Timing Accuracy: -2 ms, +10 ms or +1% (which-
ever is greater), ON-time synchronized to AC line
ALARM
POWER
CORE-10
EXPANDER-10
N a t i o n a l C o n t r o l s C o r
ALARM
GND
L1
L2
GND
Cycle Down Delay Time
L1
L2
Cycle Down Cycles
100-240 VAC
Solenoid Off Time
p.
100-240 VAC
SHOWS "SINK"
SHOWS "SOURCE"
.
3.15A
E65038
.25 DIA. HOLE (4 PL.)
(6.35)
Solenoid On Time
Solenoid Output
Pressure
+
Output
Alarm
SENSOR
SENSOR
6.875 (174.63)
6.875 (174.63)
P
P
Run
DUST COLLECTOR CONTROLS
Standby
Output Pulsing
Cycle Down
Alarm
N.O.
Pressure High Set Point
N.C.
Pressure Low Set Point
Pressure High Alarm Point
Pressure Low Alarm Point
OUTPUTS TO 120 OR 240V AC AIR SOLENOIDS
L2 TERMINALS ARE INTERNALLY CONNECTED TO L2 SUPPLY
2
2
1
1
OUTPUTS TO 120 OR 240V AC AIR SOLENOIDS
L2 TERMINALS ARE INTERNALLY CONNECTED TO L2 SUPPLY
Caution:
1. Do not mount controls in high vibration areas with-
out shock mounts.
2. Do not mount controls in areas of high dust or cor-
rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con-
trols, as we employ some very sophisticated compo-
nents that could be further damaged. For service, call
us directly: 800-323-2593.
.313 (7.95)
.313 (7.95)
.25 DIA. HOLE (4 PL.)
(6.35)
TWISTED PAIR COMMUNICATIONS CABLE
TO EXPANSION UNITS (IF USED)
TWISTED PAIR COMMUNICATIONS CABLE
TO MAIN CONTROLLER AND OTHER
EXPANSION UNITS (IF USED)
(12.7)
.50
(38.1)
1.50
4-11

Related parts for DNC-T2610-020