4610A-6-2-A ARTISAN CONTROLS, 4610A-6-2-A Datasheet - Page 3

no-image

4610A-6-2-A

Manufacturer Part Number
4610A-6-2-A
Description
Timer; Repeat Cycle On; 2s-600s; SSR; SPST-NO; 1A@115VAC; Pnl-Mnt; Quick Connect
Manufacturer
ARTISAN CONTROLS
Datasheet

Specifications of 4610A-6-2-A

Current, Rating
70 mA-5 A
Function
Timing
Relay Type
Solid State
Repeatability
1% (Nom.)
Standards
cULus, UL, CE
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
-20 °C
Termination
Quick Connect
Timer Type
Repeat Cycle
Timing Range
2 to 600 sec.
Voltage, Control
115 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is
the sole and exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written
consent of Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party
misusing this property
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Voltage Drop in “ON” State:
Energize Time Range Restrictions:
Fixed Timing Purchase Tolerance
Leakage Current in “OFF” State:
Repeatability Of Timing Period:
Tel: 973-598-9400 • Fax: 973-598-9410 • Toll Free: 800-457-4950
Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ, 07869, USA
Zero Voltage (0°) Switching:
Timing Resistor Tolerance:
Adjustable Timing Ranges:
Data Sheet Revision Date:
Timing Range Tolerance:
Operating Temperature:
Timing Resistor Rating:
Agency Recognitions:
V
Transient Protection:
Operating Voltage:
Operating Current:
I S I T
Solid State Timers and Controllers
Timing Variation:
Output Rating:
Recycle Time:
Timing Mode:
Fixed Timing:
Construction:
CE Marking:
O U R
Dielectric:
Humidity:
W E B
24VAC (18V - 30V), 48V AC (40V - 60V), 115VAC (95V - 135V),
230VAC (200V - 250V), 50/60Hz.
All voltages < 20 mA plus load current requirements.
Repeat Cycle Timing - Energize portion of cycle turns on with application of
operating voltage.
Repeat Cycle Time from 0.2 seconds to 86,400 seconds. Energize Time from
0.1 seconds to 90% of the Repeat Cycle Time.
2%, 5%, 10%, and 20% available.
5 ranges provide adjustable Repeat Cycle Times from 0.2 to 16,000 seconds,
and 5 ranges provide adjustable Energize Times from 0.1 to 8,000 seconds.
Adjustable energize times (ET) require a range restriction code ‘A’, or ‘B’ to be
added to the part number. The ‘-A’ restricts the Energize Time (ET) between
1% and 50% of whatever the Repeat Cycle Time (RCT) is set for. The ‘-B’
restricts the Energize Time (ET) between 50% and 100% of whatever the
Repeat Cycle Time (RCT) is set for.
Minimum time ±10%, maximum time ±10%. Example: The RCT adjustable
timing range -3 operates in the 4 - 200 second range with 0 - 1 meg ohm
external timing resistor. This model could exhibit a minimum time of 3.6 - 4.4
seconds with 0 ohms external timing resistance, and a maximum time of 180 -
220 seconds with an external timing resistor of 1 meg ohm. The extended
range to 2000 seconds using 10 meg ohms external timing resistance is
permitted to be 1800 - 2200 seconds, and still fall within the ±10% specification
limit.
Worst case power dissipation never exceeds 15 milliwatts.
Timing range specified is guaranteed as a minimum using 5% resistors.
Less than 6% of set point over specified temperature and voltage range.
±1% nominal.
Operating voltage must be removed for a minimum of 200 milliseconds to
guarantee all timing and output circuits have reset.
Rated for 70 mA to 5 A inductive with inrush current to 25A for 8 mS. Operation
can be extended to 10A providing the metal base of the timer is maintained at a
temperature no greater than 85°C. This can generally be achieved if ambient
temperature does not exceed 30°C and the timer is mounted to a metal chassis
that provides a minimum of 15 cubic inches of heat sink. Apply a thermal
compound between the timer’s base and the chassis.
Load is energized at zero volts in the AC operating voltage to within ±50
microseconds of zero volts in the AC operating voltage.
1.75 volts maximum at 5 amperes during Energize Time.
5 mA maximum when output switch is not energized.
Protected by silicon transient suppressors which respond to transients within
1 x 10
transient surge currents to 200 amperes for durations up to 1/120 second at
25° C. Maximum transient voltage protection is 6000 volts as delivered
through a source resistance of 30 ohms with a maximum duration of 8.3
milliseconds.
1500V rms all terminals to case or heatsink.
-20°C to +85°C.
95% non-condensing.
Encapsulated module with .25 quick connect wiring terminals.
UL File E47858, Component Appliance Controls ATNZ2 (US) & ATNZ8 (Can)
Component Auxiliary Devices NKCR2 (US) & NKCR8 (Can).
Conforms to requirements of Low Voltage Directive (72/23/EEC//93/69/EEC)
and EMC Directive (89/336/EEC//93/68/EEC)
September 8, 2008
S I T E
-12
seconds to a peak pulse power dissipation of 1500 watts, with
A T
:
www.artisancontrols.com